BFM Europe Avelli Instrucciones de montaje

Avelli
BA ANCED F UE OG EFFECT GAS FIRE
Installation, Maintenance & User Instructions
Hand these instructions to the user
Model No’s BBF **RN2 is only for use on Natural Gas (G20) at a
supply pressure of 20 mbar in G.B. / I.E.
** denotes cosmetic variant

CONTENTS
PAGE
Section 1 Information and Requirements
1.0 Appliance Information 3
1.1 Conditions of Installation 4
1.2 Fireplace surround & suitability 4
1.3 Flue Terminal Position 5
1.4 Shelf position 6
1.5 Hearths 6
Section 2 Installation of Fire
2.1 Unpacking the fire 6
2.2 Fireplace opening 7-8
2.3 Preparation of the wall 8-9
2.4 Preparation of the flue hole 9
2.5 Installation of the gas supply 10
2.6 Preparation of the flue duct 11
2.7 Securing the firebox to the opening 12-13
2.8 Installing the Avelli surround 14-15
2.9 Centralising the surround legs 16
2.10 Making the gas connection / pressure testing 17
2.11 Fitting the terminal guard 17
2.12 Removal & refitting of the glass frame 18-20
2.13 Removal & refitting of the burner assembly 21-22
2.14 Fitting the batteries to the receiver and handset 23
Section 3 Assembling Fuel Bed and Commissioning
3.1 Fitting the log fuel bed 24-28
3.2 Lighting the appliance 29-33
3.3 Fitting the handset wall bracket 33
3.4 Instructing the user / product handover 33
Section 4 Maintenance
4.1 Removal of the burner assembly 34
4.2 Removal of the gas valve 34
4.3 Removal of the pilot assembly 35
4.4 Removal of the receiver 35
Parts shortlist 36
Section 5 User Instructions
5.1 Installation Information / about your fire 37-38
5.2 Operating your fire 39-43
5.3 Removal / replacing the glass frame 44-46
5.4 Removal / replacing the log fuel-bed 47-51
5.5 Cleaning instructions 51-52
5.6 Replacement of batteries in the receiver and handset 52
User replaceable parts 53
This appliance is manufactured by :-
BFM Europe Ltd, Trentham Lakes,
Stoke-on-Trent, ST4 4TJ.
2

SECTION 1
INFORMATION AND REQUIREMENTS
1.0 APP IANCE INFORMATION
Model BBFL**RN2
** denotes cosmetic variant of product
Gas Type G20
Main injector (1 off) Size 380
Pilot Type Black Technigas “Polidoro” G27.2
Max. Gross Heat Input : 5.7 kW
Min. Gross Heat Input : 4.4 kW
Gas Rate : 0.529 m3/hr
Cold Pressure : 20.0 +/-1.0 mbar
Ignition : 6V Battery Ignition
Electrode Spark Gap 4.0mm
Packed Weight 48 kg
Gas Connection : 8mm Compression (supplied with fire)
Fig. 1
3

INSTA ATION REQUIREMENTS
Efficiency Declaration
The efficiency of this appliance has been measured as specified in
BS EN 613 : 2001 and the result after conversion to Gross using the
appropriate factor from Table 4 of SAP 2009 is 76%. The test data from which it
has been calculated has been certified by BSI. The efficiency value may be used
in the U Government’s Standard Assessment Procedure (SAP) for energy rating
of dwellings.
1.1 CONDITIONS OF INSTA ATION
It is the law that all gas appliances are installed only by a GAS SAFE Registered
Installer, in accordance with these installation instructions and the Gas Safety
(Installation and Use) Regulations 1998 as amended. Failure to install appliances
correctly could lead to prosecution. It is in your own interest and that of safety to
comply with the law.
The installation must also be in accordance with all relevant parts of the Local and
National Building Regulations where appropriate, the Building Regulations
(Scotland Consolidation) issued by the Scottish Development Department, and all
applicable requirements of the following British Standard Code of Practice.
1. B.S. 5871 Part 1 Installation of Gas Fires
2. B.S. 6891 Installation of Gas Pipework
3. B.S. 5440 Parts 1 & 2 Installation of Flues and Ventilation
4. I.S 813 : 1996 Domestic Gas Installation, issued by the National Standards
Authority of Ireland.
1.2 FIREP ACE / SURROUND SUITABI ITY
The fire must only be installed with the hearth supplied it must not be installed
directly onto carpet or other combustible floor materials.
If a heating appliance is fitted directly against a wall combustible material must be
removed from behind it. Soft wall coverings such as blown vinyl, wall paper etc.
could be affected by the rising hot air and scorching and/or discoloration may
result. Due consideration should be made to this when installing or decorating.
This product can only be installed with surround designs available from BFM
Europe td or designs which meet the criteria as required by BFM Fires. For
further details of specification requirements please contact BFM Europe
Technical Service.
4

1.3 F UE TERMINA POSITION
The minimum acceptable dimensions from the flue terminal to obstructions
and ventilation openings are shown below and listed in the table
It is important that the position of the flue allows the free passage of air
across it at all times. The minimum acceptable space from the flue terminal
to obstructions and ventilation openings are specified below (fig. 2)
Fig. 2
DIMENSION TERMINA POSITION MINIMUM DIMENSION
A Directly below an opening, air brick, 300mm (12in)
opening window
B Above an opening, air brick, 300mm (12in)
opening window
C Horizontally to an opening, air brick, 300mm (12in)
opening window etc.
D Below gutters, soil pipes or drain pipes 300mm (12in)
E Below eaves 300mm (12in)
F Below balconies or car port roof 600mm (12in)
G From a vertical drain pipe or soil pipe 300mm (12in)
H From an internal or external corner 600mm (24in)
I Above ground roof or balcony level 300mm (12in)
J From a surface facing the terminal 600mm (24in)
K From a terminal facing the terminal 600mm (24in)
From an opening in the car port 1200m (48in)
M Vertically from a terminal on the same wall 1500mm(59in)
N Horizontally from a terminal on the 300mm (12in)
same Wall
O NOT APP ICAB E N/A
P NOT APP ICAB E N/A
Q NOT APP ICAB E N/A
5

1.4 SHE F POSITION
The fire may be fitted below a combustible shelf providing there is a minimum
distance of 200mm above the top of the fire and the shelf does not project more
than 150mm. If the shelf overhangs more than 150mm the distance between the
fire and the shelf must be increased by 15mm for every 25mm of additional
overhang over 150mm.
1.5 HEARTHS
This appliance must only be installed with the BFM Europe supplied hearth panel
or an alternative item as dimensionally approved by BFM Europe.
SECTION 2
INSTA ATION OF FIRE
2.1 UNPACKING THE FIRE
Carefully lift the fire out of the carton. Remove the loose item packaging carefully
from the front of the appliance. Check the contents as listed :-
Packing Check List - All Models
Pack 1 of 2 - Combustion Chamber Pack
1 off Combustion chamber & glass frame assembly
1 off Boxed ceramic fuel-bed set (packed inside combustion chamber)
1 off Wall plate
1 off Flue terminal / pipe unit
1 off Flue terminal guard
1 off Installation / user book (combined)
1 off Loose items pack – containing :- 1 off 9V battery, 4 off 1.5V batteries
remote handset, 1 off handset wall
brkt (inc. fixings), 1 off glass removal
tool, 4 off M5 locknuts, 4 off 8mm
rawlpugs & fixing screws, 2 off
surround leg securing brackets.
Pack 2 of 2 - imestone or Travertine Surround
1 off Hearth 1 off L/H leg
1 off Shelf 1 off R/H leg
1 off Top infill 1 off Controls access panel
1 off Shelf infill section
1 off Firebox / burner assembly
6

2.2 FIRE P ACE OPENING
a) The front opening of the fire place must be between 550 and 565mm
wide and between 785mm and 795mm high. If the opening exceeds
these dimensions then a surround must be constructed from suitable
non-combustible material to produce a suitable sized opening. Any
surround must be suitably sealed to the fire place to prevent leakage.
See fig. 3 below
Fig. 3
b) The minimum / maximum sized distances between the firebox mounting
flange and outside wall are shown below and overpage in fig. 4 & 5
Fig. 4
7
550mm minimum,
565mm maximum
Fire Opening
785mm minimum,
795mm maximum
Minimum Flat
ealing Area
10mm
Minimum Installation
Depth 358mm
Maximum Installation Depth
651mm

Fig. 5
2.3 PREPARATION OF THE WA
a) The appliance and flue pipes must be installed at right angles to the
mounting wall. The appliance itself should be installed vertically against
a flat wall. Where an uneven wall surface is found, appropriate action
should be taken to ensure that the appliance is not stressed or does not
distort when installed.
b) Ensure that the floor surface onto which the appliance is mounted onto
is flat. The minimum height from the floor to the centre of the flue is
shown on fig. 6 overpage.
8
1115mm
550mm 228mm
Outer Wall
600mm Including
Firebox Flanges
300mm
Cavity
Flue Terminal

Fig. 6
2.4 PREPARATION OF THE F UE HO E
a) Mark the position of the centre of the flue on the inner wall.
b) Cut hole for outer flue pipe. There are two possible methods to achieve
this, either core drill or via hammer and chisel.
c) To core drill, proceed as follows :-
Drill a pilot hole through the wall, in position as specified in figure 6.
Using a 6” core drill, drill the flue hole.
To Hammer and chisel, proceed as follows :-
Mark the position of the centre of the flue pipe as specified in figure 6.
Mark the position of the hole around this point.
Chisel out the area as marked on the wall.
d) We then recommend that a cardboard cylinder is placed around the flue
pipe and inserted in the chiselled out hole whilst making good.
NOTE :- If the appliance is to be installed into a building under
construction, it is recommended that a non-corrosive metal
tube of 6” diameter be inserted into the position of the hole.
9
150mm diameter
582mm

2.5 INSTA ATION OF THE GAS SUPP Y
a) Before installing the firebox, decide from which side or if a rear
connection to the gas supply is required. Plan the pipe run to enter the
firebox from the left, right or rear and connect to the inlet elbow. See
below :-
b) If concealed pipe work is required plan the pipe run to enter the fire box
through the openings in the rear of the fire box and connect to the inlet
elbow. See fig. 7 & 8 below for a suggested concealed pipe layout.
Fig. 7
Fig. 8
Note : Before breaking into the gas supply a pressure drop test should be
carried out to establish that the existing pipework is sound. Always re-fit the
gas inlet plate to the rear entry point and secure with the screws provided.
10
Firebox
Fireplace
Gas upply
Firebox
Approx.
525mm Fireplace
Gas upply
Approx.
100mm
Otros manuales para Avelli
1
Tabla de contenidos
Otros manuales de Chimenea de interior de BFM Europe

BFM Europe
BFM Europe Da Vinci Illumia MK2 Instrucciones de montaje

BFM Europe
BFM Europe Eden Elite Instrucciones de montaje

BFM Europe
BFM Europe GICCI2MN Instrucciones de montaje

BFM Europe
BFM Europe Passion Series Instrucciones de montaje

BFM Europe
BFM Europe Celena Instrucciones de montaje

BFM Europe
BFM Europe Arana RC Manual de usuario

BFM Europe
BFM Europe The Collection Da Vinci Illumia Instrucciones de montaje