1. Brief Introduction
1.1. Overview
1.2. Exchange Battery
1.3. Connect Probe
2. Operating Instruction
2.1 Quick Start
2.2 Structural Block Diagram of Function Menu
2.2.2 Function Instruction
2.3 Heat Insulation Box, Protecting logged data
2.3.1 Preparing for Measurement
2.3.2 Precaution
2.3.3 Mounting Probe
3. Windows Temperature Analysis Software Windows
3.1 Uploading Data into Computer
3.2 Open Data File
3.3 Data Analysis
3.3.1 Magnify and Revert Temperature Curve
3.3.2 Setup Temperature Logging Point
3.3.3 Setup Temperature Curve
3.3.4 Setup Analysis Item (Max. Temperature, Time above Temperature etc.)

PAGE 3
Add:Rm1817, Dongcheng Int’l Plaza,No.3, Huangpu East Road,Guangzhou City, China
E-mail:sales@bevsinfo.com Http://www.bevsinfo.com
3.4 Remark the Curve
3.5 Print the Curve

PAGE 4
Add:Rm1817, Dongcheng Int’l Plaza,No.3, Huangpu East Road,Guangzhou City, China
E-mail:sales@bevsinfo.com Http://www.bevsinfo.com
Down Button, move
down the highlight
cursor
Up Button, move up
the highlight cursor
Confirm Button,
confirm the selected
the highlight item
Monitor, displaying
HMI and temperature
etc.
USB port, for download
and charging
Type K
Thermocouple
connectors1
1. Brief Introduction
1.1 Overview

PAGE 5
Add:Rm1817, Dongcheng Int’l Plaza,No.3, Huangpu East Road,Guangzhou City, China
E-mail:sales@bevsinfo.com Http://www.bevsinfo.com
1.2 Exchange Battery
The Oven Data logger is equipped with a rechargeable battery, the same as normal mobile phones.
When the monitor displays “Low Battery”, please connect the USB line to the charger or PC USB
port.
There are 3 3.7V Standard 16349 batteries (Input Voltage Limited: 4.2), please exchange as follow.
Remove the two screws with cross screwdriver
Notice the battery electrode, shunt
connection, incorrect installation will
damage the battery, even the machine.

PAGE 6
Add:Rm1817, Dongcheng Int’l Plaza,No.3, Huangpu East Road,Guangzhou City, China
E-mail:sales@bevsinfo.com Http://www.bevsinfo.com
1.3 Connect probe
BEVS Oven Data Logger can be connected with 6 K type Thermocouple connectors1s. The all 6
connectors of the machine numbered from 1 to 6, seen on the back, are accessed with the probe.
The machine will detect the connected probe automatically and display the result.
Attention: The pins of the thermocouple plug are of different width and can only be plugged-in one
way. Please keep in mind. Wrong direction will damage the connector and lead to the reversed data.
2. Operating Instruction
2.1 Quick Start
1.Insert the battery(1.2 for reference)
2.Connect the probe(1.3 for reference)
3.Start(Press the confirm button for 5 sec.))
4.Attach the probe to the work piece to be measured。
5.Select “Quick Measure” and view each probe temperature to confirm working.
6.Put the logger into the heat insulation box, pull out the connecting line and close the lid.
7.Put the box into oven and take out the logger after measurement.
8.View the temperature curve on the logger or upload it into the PC for further analysis.
If no probe is connected, the machine will not start logging.
An error message “No probe attached!” will appear on the
display.

PAGE 7
Add:Rm1817, Dongcheng Int’l Plaza,No.3, Huangpu East Road,Guangzhou City, China
E-mail:sales@bevsinfo.com Http://www.bevsinfo.com
2.2 Block Diagram of the Function Menu

PAGE 8
Add:Rm1817, Dongcheng Int’l Plaza,No.3, Huangpu East Road,Guangzhou City, China
E-mail:sales@bevsinfo.com Http://www.bevsinfo.com
2.2.2 Function Instruction
Quick Measure: Start with the original setup unless “Cover it” or “No Probe Detected”displayed.
Paint: Set paint type
Interval: Set the logging frequency from 1-3000 second.
Start/Stop Temperature: Set start or stop point to log in the sub-menu. The logging will start when a
rising temperature passes the start point and will stop when a falling temperature passes the stop
point.
Data Interval: Set the logging frequency from 1-3000 second. The “Records of Ten Groups”and
“Records of One Group”mean that the time needed to use out the memory.
Testing record: the capacity of the data logger is 500000 readings, separated into 10 memory zones,
50000 readings each zone. Each data contains 6 probes, which means that each tiny memory zone
can save 83333 pieces of data, 10 zones most. Or used as a whole zone of the ability recording
500000 pieces of data. Every new data will be recorded in the next zone no matter where the fore
zone status is and it will stop beyond 50000.
Clear data: Clear out all the data, please be cautions.
Backlight: Adjust the backlight from off to highlight or stay the original setup screen off in 10
seconds without any operating.
Set Unit: SELECT this option to set the instrument in either Celsius or Fahrenheit.
Set Language: choose your favored language
Temperature Range: set the max temperature, but the lower, the more accurate. Please be cautious
that the actual temp beyond the setting will lead an error.
Date and Time: Set the date and time as the logging date and time.
Review Stored Data: Checkup the stored data and curve, which named after the testing date and

PAGE 9
Add:Rm1817, Dongcheng Int’l Plaza,No.3, Huangpu East Road,Guangzhou City, China
E-mail:sales@bevsinfo.com Http://www.bevsinfo.com
number of testing times.
No.: Working times
Start Timing: the local time of starting a test.
Total: numbers of logged data. (Each data contains six records of the six probes)
Diagram: curve based on the current data.
Delete: delete the selected data
2.3.1 Prepare to test
Step1: Make sure the box at room temperature.
Step 2: Open the box and place the blue heat absorber with the aperture for the instrument facing
upwards.
Step 3: Place the data-logger with the probes already connected inside the blue absorber.
Step 4: Lead the probe cables over the gasket and edge of the box at the cable outlet point.
Step 5: start logging
Step 6: Mount the cover on box and make sure the stainless steel edge slides a few millimeters over
the box at all sides. Also check if the cutout of the cable outlet of the cover is facing the same cutout
in the box and the probe cables are placed properly.
Step 7: Tighten the cover with the four latches and check again if the box is properly closed at all
sides.
2.3.2 Handling Precaution
*Always wear heat protective gloves when taking out the box out of the oven.
*Open the box as soon as possible after the test
*Take logger and heat collector out of the box in order to cool down. Note that the heat collector
needs quite a long time to cool down once heated up.
*When stored do not lock the cover with the latches in order to increase the lifetime and elasticity
of the rubber gasket!
2.3.3 Mounting Probes

PAGE 10
Add:Rm1817, Dongcheng Int’l Plaza,No.3, Huangpu East Road,Guangzhou City, China
E-mail:sales@bevsinfo.com Http://www.bevsinfo.com
Please make sure that the probe cables are free from objects and the oven walls, floor, sealing and
burners etc. to prevent them from hooking which may cause severe damage to probe and instrument.
Also check if the probes are placed securely so they will not come off during the process.
1. The magnet surface probe
This probe can be placed on any ferrous steel object. The sensing part is located exactly in the
middle of the probe.
2. The clamp surface probe
This probe can be placed on any object by using the clamp. The sensing part is located inside the
jaw of the clamp, insulated by a small piece of ceramic. There is some friction on this part in order
to let the sensing part align itself to the surface to make good contact.
Take the clamp between thumb and forefinger, check, which jaw has the sensing part and place the
probe at the preferred location on the object. Maximum reach of the clamp is 20mm.
3. The clamp air probe
This fast responding probe has its sensing part inside the little steel protective tube.
Connect the probe to the object or conveyor belt in the same way as the clamp surface probe. Wear
the protective gloves to remove the probe by grabbing the probe head not the cable.
Tabla de contenidos
Otros manuales de Equipo de prueba de BEVS
Manuales populares de Equipo de prueba de otras marcas

SMART
SMART KANAAD SBT XTREME 3G Series Manual de usuario

Agilent Technologies
Agilent Technologies BERT Serial Manual de usuario

Agilent Technologies
Agilent Technologies N3280A Manual de usuario

Vernier
Vernier Go Direct Voltage Manual de usuario

Lifeloc
Lifeloc R.A.D.A.R. Manual de usuario

Fluke
Fluke T5-600 Instrucciones de funcionamiento e instalación