Best D49M30SB Manual de usuario

Models: D49M30SB, D49M36SB, D49M48SB
Downdraft Ventilator
For use with these blowers
(purchase blowers separately):
Model PF6* - Flex Blower - Interior
Models EB6, EB9*, EB12*, or EB15* - Exterior
Models ILB6, ILB9 or ILB11* - In-Line
* Recommended models
READ AND SAVE THESE INSTRUCTIONS
Register your product online at: www.BestRangeHoods.com
Français p. 33
Español p. 65

2
Table of Contents
Safety Information.................................................................................................................................................................................. 3
Contents.................................................................................................................................................................................................. 4
Specifications......................................................................................................................................................................................... 4
Tools Needed........................................................................................................................................................................................... 4
Planning
Before You Begin ............................................................................................................................................................................... 5
Taking Measurements........................................................................................................................................................................ 5
Ducting Configurations ...................................................................................................................................................................... 5
Cabinet Cutouts................................................................................................................................................................................. 10
Preparing the Downdraft
Side or Rear Ducting.......................................................................................................................................................................... 12
Front Ducting..................................................................................................................................................................................... 12
Electrical Panel in Remote Location ................................................................................................................................................... 13
Final Assembly................................................................................................................................................................................... 13
Installation
Cutting Countertop Opening............................................................................................................................................................... 14
Install Housing into Cabinet................................................................................................................................................................ 15
Install Finishing Trim.......................................................................................................................................................................... 16
Installing Ductwork............................................................................................................................................................................ 16
Electrical Wiring Installation
Flex Blower Only................................................................................................................................................................................ 17
Exterior or In-Line Blower Only .......................................................................................................................................................... 18
Appliance Installation/Operation ........................................................................................................................................................... 19
Use and Care........................................................................................................................................................................................... 20
Optional Accessories.............................................................................................................................................................................. 21
Appendices A-G...................................................................................................................................................................................... 23
Warranty ................................................................................................................................................................................................. 30
Service Parts........................................................................................................................................................................................... 31

3
Safety Information
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number on the back page.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. Do not install this product with the activating switch directly
behind a burner or element. Minimum distance between the
switch and the edge of the burner should be 4 inches.
9. Loose-fitting or hanging clothing should never be worn when
operating this appliance. They may be ignited by burners/
elements on cooktop.
10. Children should not be left alone or unattended in the area
where this appliance is in use.
11. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boil
overs cause smoking and greasy spillovers that may ignite.
Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
cooking flaming foods.
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE AND
CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit. Based on
“Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off
power unit.
4. Clean filters and grease-laden surfaces frequently.
5. Do not repair or replace any part of this appliance unless
specifically recommended in this manual. All other servicing
should be done by a qualified technician.
6. Please read specification label on product for further
information and requirements.
7. To reduce the risk of fire and electric shock, install this
downdraft only with blower models shown below. Other blower
models cannot be substituted. (Blowers sold separately).
Flex Blower Model PF6, Exterior Blower Models EB6, EB9,
EB12, or EB15 In-Line Blower Models ILB6, ILB9, or ILB11.
INSTALLER: Save this manual for Electrical Inspector
and Homeowner to use.

4
Contents
E
F
G
H
I
C
D
B
A
AA
BB
CC
x3
x2
x8
x2
J
L
K
ELECTRICAL
SPECIFICATIONS
Model PF6 - Internal Flex:
120 VAC • 60 Hz • 3.0 A
Models EB6, EB9, EB12, or EB15 - Exterior
Models ILB6, ILB9 or ILB11 - In-Line
120 VAC • 60 Hz • 6.0 A (max.)
Part Description Quantity
AUpper support bracket (left) 1
BDowndraft ventilator housing 1
CEnd cap trim (left) 1
DEnd cap trim–up button (right) 1
E4" support leg (left) 1
F2" support leg (left) 1
GDischarge cover 3
HFront panel cover 1
Part Description Quantity
IElectrical panel 1
JUpper support bracket (right) 1
K4” support leg (right) 1
L2” support leg (right) 1
AA 1/4-20 x .50 Hex Head screw 2
BB #10 x .50 Phillips round head screw 8
CC #8-18 x .375 Phillips screw 2
Tools Needed
Measuring tape, pencil, Phillips screwdriver #2, nut drivers (11/32", 3/8", 7/16"), box-end wrench, saw, spirit-level, tin snips, work gloves,
and aluminum tape. (DO NOT use insulating tape.)

5
Planning
Due to its flexible design, this downdraft system can be used to
exhaust airborne contaminants when cooking with a variety of gas
or electric cooking appliances - including cooktops, rangetops,
slide-in ranges and free-standing ranges.
It can be mounted in island, peninsula, or conventional wall
locations. The blower (purchase separately) and electrical panel
can be mounted to the downdraft unit, inside the cabinet, or in a
convenient remote location.
This unit can be easily installed following these basic steps:
• Cut out the countertop opening.
• Mount the unit in the cabinet.
• Install the blower and electrical panel.
• Connect the ductwork and electrical.
• Install the trim.
• Install the cooking appliance.
Note: the high level of air flow of this appliance may affect the
gas flame on some types of gas cooktops. This is NORMAL and
will cause no harm, but can be corrected by lowering the speed
of the blower.
Gas Cooktop Seal Kit is recommended for use with all gas
cooktops. The kit creates a seal between the cooktop and the
lower cabinet. Includes trim bracket and trim seal. See Optional
Accessories section.
Taking Measurements
• Refer to the cooktop installation instructions for dimensions
of cooktop, countertop cut-out, and cabinet requirements.
However, it is recommended that oversized cabinets be used
for easier installation. Custom island designs need to account
for deeper cabinets - especially when installed with a range in
front of the downdraft or when mounting the blower behind the
downdraft. You must also plan for an access door.
• Cooktop depth can vary greatly from one to another. This
may cause the fit of these two appliances to be rather tight.
Pay special attention to the areas of potential interference
highlighted above. A countertop with (A) a raised lip and/or (B)
a backsplash may not allow enough flat countertop for a proper
installation. Note that 2-3/4" of flat countertop is required
behind cooktop and that 2-1/2" is necessary between the back
edge of the cooktop and the inside of cabinet back.
2-1/2"
A
B
2-3/4"
Downdraft
Cooktop
Front to Back
Inside Cabinet Depth
CountertopCountertop
Before You Begin
Downdraft
8" Round Elbow
*To Model 643 (8" Round Wall Cap)
*
PF6 (Flex Blower)
8
"
Straight Duct
Wiring Box
Ducting Configurations Front Exhaust with Flex Blower
• The downdraft blower system is designed for use with 8"
round ductwork using a flex blower or 10” round ductwork
using a remote blower. (Purchase blowers separately.)
• For best performance: Choose the ducting option which allows
the shortest length of ductwork and a minimum number of
elbows and transitions. Check location of floor joists, wall
studs, electrical wiring or plumbing for possible interference.
For more detailed ducting information see appendices A-G
at the end of document.

6
Ducting Configurations (continued)
Planning
Front Exhaust with Flex Blower (through cabinet)
Wiring Box
Downdraft
PF6 (Flex Blower)
8
"
Straight Duct
8
"
Round Elbow
*To Model 643 (8" Round Wall Cap)
*
Downdraft
Wiring Box
ANKD (Recirculation Kit)
PF6 (Flex Blower)
8
"
Straight Duct
Front Exhaust with Flex Blower and
Recirculating Kit Front Exhaust with Flex Blower (through
cabinet) and Recirculating Kit
Wiring Box
Downdraft
PF6 (Flex Blower)
8
"
Straight
Duct
8
"
Round Elbow
ANKD (Recirculation Kit)

7
Planning
Ducting Configurations (continued)
Side Exhaust with Flex Blower
Downdraft
1-7/8" to 8"
Round Transition
8" Round Elbow
PF6 (Flex Blower)
8
"
Straight Duct
*
*To Model 643 (8" Round Wall Cap)
8
"
Straight Duct
Downdraft
1-7/8" to 8"
Round Transition
Flex Blower
8" Straight Duct
Recirculation Kit
*
*To Model 643 (8" Round Wall Cap)
Downdraft
8" Round Elbow
PF6 (Flex Blower)
8
"
Straight Duct
1-7/8" to 8"
Round Transition
Side Exhaust with Flex Blower and
Recirculating Kit Rear Exhaust with Flex Blower

8
Planning
Downdraft
8
"
or 10
"
Round Elbow
8
" or 10"
Straight Duct
* To one of the following:
• Model PF6 (Flex Blower)
Model 643 (8" Round Wall cap)
• Model EB9 (900 cfm 10" Exterior Blower)
• Model ILB11 (10" Round In-Line Blower)
Model 441 (10" Round Wall Cap)
• Model EB12 (1200 cfm 10" Round Exterior Blower)
• Model EB15 (1500 cfm 10" Round Exterior Blower)
Note: Flex blowers require 8" ducting. External or in-line blowers require 10" ducting.
*
Downdraft
1-7/8" to 8" or
10" Round Transition
8" or 10"
Round Elbow
8" or 10"
Straight Duct
* To one of the following:
• Model PF6 (Flex Blower)
Model 643 (8" Round Wall cap)
• Model EB9 (900 cfm 10" Exterior Blower)
• Model ILB11 (10" Round In-Line Blower)
Model 441 (10" Round Wall Cap)
• Model EB12 (1200 cfm 10" Round Exterior Blower)
• Model EB15 (1500 cfm 10" Round Exterior Blower)
Note: Flex blowers require 8" ducting. External or in-line blowers require 10" ducting.
*
Side Exhaust with Remote Blower
Ducting Configurations (continued)
Front Exhaust with Remote Blower

9
Planning
Downdraft
1-7/8" to 8" or 10"
Round Transition
8" or 10" Round Elbow
8
"
or
10"
Straight Duct
*
* To one of the following:
• Model PF6 (Flex Blower)
Model 643 (8" Round Wall cap)
• Model EB9 (900 cfm 10" Exterior Blower)
• Model ILB11 (10" Round In-Line Blower)
Model 441 (10" Round Wall Cap)
• Model EB12 (1200 cfm 10" Round Exterior Blower)
• Model EB15 (1500 cfm 10" Round Exterior Blower)
Note: Flex blowers require 8" ducting. External or in-line blowers require 10" ducting.
Downdraft
1-7/8" to 8"
Round Transition
8" Round Elbow
8" Straight Duct
Dual 8" Round to 10" Round Transition
* To one of the following:
• Model EB9 (900 cfm 10" Exterior Blower)
• Model ILB11 (10" Round In-Line Blower)
Model 441 (10" Round Wall Cap)
• Model EB12 (1200 cfm 10" Round Exterior Blower)
• Model EB15 (1500 cfm 10" Round Exterior Blower)
*
Dual Duct Side Exhaust with Remote Blower
Ducting Configurations (continued)
Rear Exhaust with Remote Blower

10
Planning
CAUTION
BEFORE CUTTING HOLE IN CABINET FOR DUCTWORK,
check for interference with floor joists, wall studs,
electrical wiring, or plumbing.
Use the dimensions in illustrations to help plan how and where to
provide duct access through your cabinet. Generally, 1-7/8" x 19"
rectangular duct will be used through left, right, and back of
cabinet - while 8" round duct will be used through cabinet floor.
For left, right, or rear exhaust: Allow at least 18" for transition and
elbow or blower.
For left / right exhaust: a 30" deep cabinet is recommended to
align properly with flex blower. Flex blower can be mounted to rear
cabinet wall or to a platform / frame (not provided) on the base of
the cabinet floor. (See flex blower instructions).
Note: Flex blower can only attach to the front of the downdraft.
Cabinet depths of 24" to 30" are required - depending on the
type of cooking appliance.
If using a Recirculating Kit, see “Plan the installation”
section of the installation instructions packaged with the kit.
Cabinet Cutouts
Rear Ducting Cutout
21"
(53.3 cm)
21"
(53.3 cm)
Appliance
Cutout
4"
(10.2 cm)
24-3/4"
(62.9 cm)
24-3/4"
(62.9 cm)
4"
(10.2 cm)
5-7/8"
(14.9 cm)
5-7/8"
(14.9 cm)
21"
(53.3 cm)
21"
(53.3 cm)
Appliance
Cutout
2"
(5.1 cm)
Side Ducting Cutout
Otros manuales para D49M30SB
3
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Idiomas:
Otros manuales de Admirador de Best