sensor is triggered, it sends adjustable parameter “BASIC SET” command to a lamp under
Group2, you can adjust the lamp’s luminance through the parameters of this command; if the set
light-up time out (see the Configuration Description), the sensor will send “BASIC
SET”command to turn-off the lamp.
When sensor is triggered:!
[Command Class Basic,Basic Set,Value = 0xFF(default 0xFF, configurable, see the
Configuration Description)] When light-up time out:!
[Command Class Basic,Basic Set,Value = 0x00]
Configuration Description
a) “Basic Set” configuration!
If there is any device under Association Group2, the door sensor will send “Basic Set = value”
command to control that device when the door sensor is opened. “Value” configuration rule is as
below:
b) Turn Off Light Time Configuration!
If there is any device under Association Group2, the door sensor will send “Basic Set = value”
command to Group2, and send “Basic Set = 0x00” command to turn-off light after “t” seconds,!
Set value = “t”, means to send Basic Set command after “t” seconds.
c) PIR Sensor Alarm Elimination Time Configuration!
Min set time is 5s. If the configuration is 1, that means it will eliminate alarm after 1*5s (5
seconds), if t, will eliminate alarm after t*10s.
Z-Wave Supportive Commands