BEAMEX ePG Manual de usuario

ePG
Electric Pressure Pump and Controller
Dear user,
We have made every effort to ensure the accuracy of the contents of this
manual. Should any errors be detected, we would greatly appreciate to
receive suggestions to improve the quality of the contents of this manual.
For more detailed technical data about Beamex ePG Electric Pressure
Pump and Controller, please contact the manufacturer.
© Beamex 2022
Beamex Oy Ab
Ristisuonraitti 10
FIN-68600 Pietarsaari
Finland
Tel:
E-mail:
Internet:
+358-10-5505000
https://www.beamex.com
8805000 / ePGuEng / Version 1.0

ii - Table of Contents
Table of Contents
Prologue....................................................................................3
Typographical Conventions................................................................3
Unpacking and Inspection................................................................. 3
Feedback............................................................................................5
Safety.........................................................................................6
Approvals........................................................................................... 6
Symbols Used on the device.............................................................6
Operating Environment and Specifications........................................6
Safety Precautions and Warnings..................................................... 9
General Warnings Concerning Pressure Measurement.................. 10
About ePG.............................................................................. 11
General.............................................................................................11
Top view...........................................................................................12
Battery Pack.....................................................................................13
Operating instructions...........................................................15
Setting Up........................................................................................15
User Interface and Functionality......................................................16
Troubleshooting.....................................................................20
Maintenance............................................................................22
Cleaning Instructions........................................................................22
Cleaning The Output Valve............................................................. 23
Changing The Non-return Valve Package.......................................25
Changing The Piston Seals.............................................................28
Changing the Adhesive Vent...........................................................31
Firmware update..............................................................................32
Related Products....................................................................33
Disposal of Waste Electrical and Electronic Equipment....34
Beamex and WEEE.........................................................................34
Service and transportation instructions..............................35

Prologue - 3
Prologue
Thank you for buying Beamex ePG, Electric Pressure Pump and
Controller.
Beamex ePG is a portable, hand-held, battery-powered device that is used
to generate reference pressure in pressure calibration applications. With
ePG you can generate pressure between -0.85 to 20 bar / -12.4 to 300
psi. Since the device does not have a display to indicate the generated
pressure reading, it must be connected to an external pressure device
with an appropriate display, e.g. Beamex pressure calibrator or a pressure
indicator. ePG contains a lithium-ion battery pack that can be charged
using a USB Type-C charger either separately or while attached to the
device (see chapter Battery Pack).
Typographical Conventions
The following typographical conventions apply to the ePG User Manual:
Bold text is used in following situations:
• References to User Manual topics and parts
• ePG keywords, i.e. terms shown in the User Interface and
Note: This is a note. Notes typically inform you of something
useful concerning the current topic.
Caution: This is a caution. Whenever you see a caution, read
it carefully and take it seriously. By not observing cautions, you
may damage the pump.
Warning: This is a warning. Whenever you see a warning, read
it carefully and take it seriously. By not observing warnings, you
may -at worst- damage the pump and/or get personal injury.
Unpacking and Inspection
At the factory, each new ePG passes a careful inspection. It should be
free of scrapes and scratches and in proper operation condition upon
receipt. The receiver should, however, inspect the unit for any damage
that may have occurred during transportation. If there are signs of obvious
mechanical damage, package contents are incomplete, or ePG does not

4 - Prologue
operate according to specifications, contact the purchasing sales office as
soon as possible.
If you have to return the device to the factory for any reason, use
the original packing whenever possible (see chapter Service and
transportation instructions). Include a detailed description of the reason for
the return.
ePG is available in two different configurations with different delivery
contents:
ePG Pump Only (9021000)
• ePG with a hand strap
• Battery pack (8006030)
• USB Type-C charger with a country-specific power cord and mains plug
• Warranty terms
• Accessories flyer
• This User Manual (8805000)
ePG Complete Kit (9021115)
• ePG with a hand strap
• Shoulder strap (8006110)
• Battery pack (8006030)
• USB Type-C charger with a country-specific power cord and mains plug
• USB Type-A to Type-C communication cable (6690980)
• A carrying case with foaming and places for hoses, charger and a USB
communication cable, etc (8003350)
• Pressure T-hose with NPT fittings (8009550)
• Pressure fitting plug set (8003610)
• A package of USB Type-C dust covers (8006120, 5 pcs)
• Warranty terms
• Accessories flyer
• This User Manual (8805000)
OPTIONS, ACCESSORIES AND SPARE PARTS
• Battery pack (8006030)
• USB Type-C charger (8006090, EU) with a country-specific power cord
and mains plug:
◦ AU (8006091)
◦ UK (8006092)
◦ US (8006093)
• USB Type-A to Type-C communication cable (6690980)
• Shoulder strap (8006110)

Prologue - 5
• A carrying case with foaming and places for hoses, charger and a USB
communication cable, etc (8003350)
• Pressure T-hose (8009550)
• Pressure fitting set for connecting high pressure EXT module to the low
pressure hose (8003100)
• Pressure fitting plug set (8003610)
• A package of USB Type-C dust covers (8006120, 5 pcs)
• Set of Mesh filters for the output connector (8006160, 5 pcs)
• Set of Adhesive Vents (8006165, 3 pcs)
• ePG Piston Seal Service kit: piston seals and cylinder's o-ring
(8006130)
• ePG Cylinder Service kit: cylinder and o-ring (8006140)
• ePG Non-return valve kit: non-return valves and o-rings (8006145)
All these are available at https://shop.beamex.com/
Feedback
We want to improve our products and services constantly. Therefore we’d
like to know your opinion of the product you use. Please spend a moment
of your valuable time by giving us feedback about the product.
Beamex Oy Ab
Quality Feedback
Ristisuonraitti 10
FIN-68600 Pietarsaari
Address:
FINLAND
E-mail: [email protected]
Internet: https://www.beamex.com

6 - Safety
Safety
Approvals
All available approvals and declaration of conformity can be downloaded
from Beamex's website.
Symbols Used on the device
Caution! Please read the manual for further
information
Operating Environment and
Specifications
Warning: Only use the device for purposes and in
environments specified in the user manual.
Caution: Do not exceed the max. operating pressure of the
device and the hose.

Safety - 7
Table 1: Specifications
SPECIFICATION ePG
Pressure Range1-0.85 to 20 bar / -12.4 to 300 psi
1 Valid at nominal barometric
pressure of 1013 mbar abs” /14.7
psi abs
Pressure Generation Rate
from 0 to 20 bar / 300 psi2< 110 s
from 0 to -0.85 bar / -12.4 psi2< 45 s
2 into a volume max.20 ml / 0.68
fl.oz.
Setpoint Adjustability3
from 0 to 20 bar / 300 psi < 10 mbar / < 0.1 psi
from 0 to -0.85 bar / -12.4 psi < 5 mbar / < 0.05 psi
3 into a volume 20 ml / 0.68 fl.oz.
Wetted Parts Aluminum, brass, stainless steel,
NBR, FKM, PEEK, PA, MS, TPE,
food grade lubricants
Dimensions See technical drawing: Figure 1:
Technical drawing.
Weight ~ 2.3 kg / ~ 5 lb
Pressure Ports G1/8" (ISO228/1) female port with
adapter for Beamex low pressure
hose
Filter Elements A filter element (36 micron)
included in the pressure port
Pressure Media Clean dry non-corrosive gases
Battery Pack Li-ion battery pack with USB Type-
C connector, 14.4V, at least 2600
mAh
Charger (minimum requirements) USB Type-C charger PD 2.0/3.0
Profile 4 20V / 2.25A / 45W

8 - Safety
SPECIFICATION ePG
Storage Temperature -20 to 60 °C / -4 to 140 °F
Operating Temperature 0 to 50 °C / 32 to 122 °F
Humidity
from 0 to 40 °C / 32 to 104 °F ≤ 90 %RH
from 40 °C to 50 °C / 104 to 122 °F ≤ 50 %RH4
4 ePG will work at higher humidity,
but its performance may drop
Note: If the device has been stored in different environment it
should be stabilized to the new environment before use.
Note: Please notice that these specifications apply at sea-level.
Note: Please notice that generated pressure is limited to 20.7
bar / 300.2 psi.

Safety - 9
Figure 1: Technical drawing
Safety Precautions and Warnings
Caution: Read and fully understand this manual and all other
safety instructions before operating this Electric Pressure Pump
and Controller.
Warning: Only personnel with good experience and knowledge
of pressure media, pressure instruments and connections are
allowed to work with ePG. Incorrect use may result in damage to
the device, the instrument connected to it and/or personal injury.
Warning: Use only the pressure measurement T-hose delivered
by Beamex, marked with "Max. 40 bar". Other hoses may not
withstand the pressure generated by ePG.
Warning: Wear protective glasses.
Warning: Do not connect the device to an external pressure
source.

10 - Safety
Warning: Vent external systems before connecting to the
device.
Warning: Ensure that all connections are made correctly and
the hose and the connectors are undamaged. Do not use faulty
hoses or connectors.
Warning: Use only the connector provided with ePG. Impurities
from wrong materials may block the device.
Warning: Do not use Teflon (PTFE) tape to seal anything in the
device.
Warning: Do not use ePG in any other way than as described
in this manual.
General Warnings Concerning
Pressure Measurement
Warning: Always depressurize the system before opening
or connecting any pressure fittings or connectors. Use proper
valves for venting the system. Ensure that all connections are
made correctly and that the hose and the connectors are intact.
Warning: Never exceed the maximum pressure of connected
devices. The maximum pressure of Beamex modules is stated
on module's sticker.
Warning: Never plug a hose with your hands or put hands in
front of a gas spray coming from a leakage. A gas bubble in the
blood circulation can cause death.
Warning: Do not use the same tubing with different liquids or
gases.
Tabla de contenidos
Otros manuales de Bomba de agua de BEAMEX
Manuales populares de Bomba de agua de otras marcas

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guía de solución de problemas

DUROMAX
DUROMAX XP WX Series Manual de usuario

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manual de usuario

Franklin Electric
Franklin Electric IPS Manual de usuario

Xylem
Xylem e-1532 Series Manual de usuario

Milton Roy
Milton Roy PRIMEROYAL Manual de usuario



















