Version 0.1 3 July 2013 www.iHome.eu
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_BATTERY
COMMAND_CLASS_WAKE_UP
COMMAND_CLASS_VERSION
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_MARK,
COMMAND_CLASS_CENTRAL_SCENE,
COMMAND_CLASS_BASIC
Not listening Routing SLAVE
This Z-Wave product will be used as routing slave. Slave nodes are nodes in a Z-Wave network that receive
commands and perform actions based on the command. This device will always be in sleep mode because it
works on batteries. In sleep mode the device is not active listening, the device will wake up according to the
wakeup command class.
Include Initiator
The include initiator is used when Primary and Inclusion Controllers include nodes into the network. When
both the include initiator have been activated simultaneously the new node will be included to the network (if
the node was not included previously).
Exclude Initiator
The exclude initiator is used by Primary Controllers to exclude nodes from the network. When the exclude
initiator and a slave initiator are activated simultaneously, it will result in the slave being excluded from the
network (and reset to Node ID zero). Even if the slave was not part of the network it will still be reset by this
action.
Z-Wave compatibility
Because this is a Z-Wave device, it means it can co-operate with other Z-Wave devices of other manufacturers.
It can co-exist in a Z-Wave network existing with product from other manufacturers.
Hops & Retries
The Z-Wave range has a range of up to 30 meters in line of sight. This signal is not limited to the 30 meter
range due to routing the Z-Wave message to other nodes in the network. This way the range of the Z-Wave
network can be expanded to 150 meters indoors (limit of 4 hops).
class: 0x20 COMMAND_CLASS_BASIC
The supporting role of the basic command class is mapped to the switch binary command class.
class: 0x86 COMMAND_CLASS_VERSION
This Command Class is used to obtain information about the Scene Controller. The Z-Wave library type, the Z-
Wave protocol version and the application version will be reported.
class: 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC
This will report information about the manufacturer. This product will contain the manufacturer ID of BeNeXt.
Manufacturer ID of BeNeXt is 138, the ID of this product is 20.
class: 0x5B COMMAND_CLASS_CENTRAL_SCENE
This command class is used to send a CENTRAL_SCENE_NOTIFICATION to a controller to activate a scene.