7
6LED signals / troubleshooting
6.1 Hyperion 3D-M, Hyperion 3D-S
6.2 Hyperion 3D-H
Button LED Description Troubleshooting
Brief press
(< 1 s)
1x green Battery full
1x yellow Low battery Plan battery change
1x red Battery critical Change battery
Long press
(> 3 s,
LED ashes
white 1x/s)
Blue ashing Searching for master sensor
3x green Connection to master sensor
established successfully
3x red Connection to master sensor failed Repeat pairing to master sensor:
Use app Bircher SmartConnect
LED Description Troubleshooting
White Sensor powered,
ready for operation
Red Power-up The sensor will not detect objects or react to commands
Red blinking Conguration mode
(parameter change in progress)
The sensor will not detect objects.
Exit access by app Bircher SmartConnect
Red/green/blue
blinking
Calibration
(1st time background teach-in)
The sensor will not detect objects or react to commands
Blue Vehicle approaching door To prevent door opening set people/vehicle parameter
Green Person approaching door To prevent door opening set people/vehicle parameter
Turquoise Unknown object approaching
door
Door might open to full height
Blue/green blinking Object in presence zone Free presence zone
White blinking Manual operation of door or
digital input (dig IN) active i.e.
sensor deactivated, see page 3
The automatic operation of the door will be ceased until the door gets
closed again by manual command.
red yellow Error Start calibration again by app Bircher SmartConnect or temporary
cutting power
red blue Error Press button on height sensor for 3s (remove cover), possibly start
calibration again
red yellow white Error Clean lenses on master sensor (slave sensor).
Check light condition > 50 lux.
red yellow blue Error Check power supply on master sensor, if error only on slave sensor ->
Check wiring from master sensor to slave sensor
red yellow yellow Error Observe temperature specication, possibly add weather hood
red yellow red Error Exchange master sensor (slave sensor)
red blue white Error Clean lenses on height sensor
red blue blue Error Check batteries on height sensor
red blue yellow Error Restart height sensor by temporary cutting power, possibly change
batteries. Check if door can be manually opened by door controller.
red blue red Error Exchange height sensor
red white blue Error Check wiring from master to slave sensor,
Exchange slave sensor
red white red Error Check opposite sensor
A list of previous errors can be found in the mobile app.