Power switch:
To turn on: Press < 5 seconds
To turn o: Press > 5 seconds
7TERREPOWER EASY BATTERY MANUAL 10 kWh / 15 kWh6TERREPOWER EASY BATTERY MANUAL 10 kWh / 15 kWh
8. Parallel connections of several batteries should be made by means of copper plates.
9. The battery is shipped fully activated and ready for operation.
10. Make sure that there is no short-circuit in the external elements.
11. The battery cannot be connected to AC power directly.
12. Ground the battery.
13. Make sure the battery is compatible with external equipment.
14. Keep the battery away from re and water.
15.. The battery may only be connected in parallel with another battery of exactly the same type and voltage.
16. It is forbidden to connect the battery with other batteries of different types or brands and models.
17. The battery must not be operated with defective or incompatible inverters.
18.. Tampering with the inside of the battery is prohibited.
19. In case of re, only dry powder re extinguishers may be used, liquid extinguishers are prohibited.
20. Do not open, repair, or disassemble the battery.
21. Only Easy Battery personnel may repair the battery. We do not assume any consequence or related liability that is
due to violation of safety operation or violation of design, production and equipment safety standards.
22. If the battery is stored for a long time, it is advisable to charge it every six months.
23. The battery must be recharged within 12 hours after complete discharge.
24. Contact the supplier as soon as possible if you notice anything abnormal.
25.. Warranty claims are excluded for direct or indirect damage due to the above items.
26. During handling, be very careful to avoid knocks/drops to the battery.
27. Be careful not to touch both contacts at the same time, there may be a risk of electric shock.
28. The battery, at the end of its useful life, requires a valorization process, do not disassemble it.
29. Avoid placing the batteries in humid places to avoid risks.
30. If the battery has liquid leaks, avoid contact with it completely.
4. Installation
When installing the batteries TerrePower Easy Battery, the charge and discharge parameters to be entered in the inverters and
regulators and the temperature values (see section 1.1) must be taken into account.
The batteries TerrePower Easy Battery, have no communication to the external elements and may require a special conguration
of these devices for their operation.
Each battery power cable can carry a maximum of 125 A.
•With 48 V systems, the use of an inverter higher than 6000 W is not recommended.
•With the 87 V system it is not recommended to use an inverter higher than 9900 W per battery.
Install the battery in a place where there is no risk of falling and where there are no ammable or explosive materials nearby.
It is recommended to use 125A fuses and fuse holders that cut off the power supply between the battery and external elements.
From power switch you can activate or deactivate the charge and discharge of the battery.
With a short press <5 seconds the battery enable the charge/discharge and the button´s red light lights up.
With a large press >5 seconds the battery disable the charge/discharge and the button´s red light turns off.
1.3 Front panel
The battery connectors are connected
by pressing and disconnected by pressing
a small button on each connector.
To avoid damage to the connectors,
the circuit must be open when
connecting or disconnecting to the battery
2. Installation diagram
It is mandatory to use the battery with inverters that allow regulating the
minimum cut-off voltage, also if it is a hybrid you will need to congure
the charging voltages according to the model specication, (operating
range 10 kWh 48 V: 40 V to 50 V; operating range 10 kWh HV: 79.2 V to
101 V; operating range 15 kWh: 40 V to 50 V).
If solar regulators are used, these must not exceed the load value indica-
ted according to the model.
An incorrect load conguration can cause the battery BMS to give a stop
command and the battery must be serviced and restarted.
A fuse must be installed between the battery and the inverter with the
following characteristics:
Part No. 422063
Manufacture dF electric
DC cut-off current (A) 125
Interrupting capacity (kA) 80
3. Safety
1. It is mandatory to read the battery instructions before use to avoid possible damage.
2. Keep the battery away from high voltage and out of the reach of children.
3. Before connecting make sure that the polarity is correct between the battery and the inverter or solar regulator.
4.
Use safety equipment such as:
•Insulating gloves
•Protective goggles
•Safety shoes
5. Use only cables with connectors in good condition.
6. It is advisable to use 125A fuses and fuse holders.
7. If the ambient temperature is outside the range indicated in section 1.2, the battery will stop working for safety re-
asons.