Document Number: 1900-0098 Issue Date: 01/15/08 Revision No: 003 Page: 3 of 44
SPECIFICATIONS ( WI-0081-A )
Bayne THINLINE ®Premium Lift Systems
A. Rotary Actuator - rack and pinion style design.
•Rack, pinion, and shaft bearings are constantly lubricated by the hydraulic oil for
extended life.
•Body and caps are made of high quality ductile iron.
•Pinion output shaft and racks are made of high tensile alloy steel.
•The rotary actuator provides smooth motion throughout the lift cycle, which results in
longer cart life with virtually no cart damage or abuse.
B. Arm bearings are made of a composite material which provides superior compression
strength along with self-lubrication, thus eliminating the need to grease the arm bearings.
C. The THINLINE®lift unit can measure as little as 5” thick from the front of the mainframe
to the front of the faceplate depending on the types of arms used. This allows for easy
dumping of large commercial containers without interference.
D. The faceplate is normally at 45 degrees in the dump position and extends 13” to 15” from
the back of the mainframe into the hopper or container opening. This places the cart or
barrel 16” to 18” into the truck or container opening thus reducing any potential spillage
of materials.
E. Cycle times for safe, fast, efficient service.
•6 - 8 seconds for rear-load and side-load units
•8 - 10 seconds for units with 9” and 15” vertical lifts
•10 - 12 seconds for stationary, recycling, and double wide, and 24” vertical units
•15 - 30 seconds for 3300 series and 3300 series stationary units
Note : Cycle time is controlled by flowrate, as flowrate increases, cycle times decrease.
Warning : Never exceed the cycle times listed above. In order to avoid injury and
maintain manufacturer’s warranty never operate outside of these recommendations.
F. Recommended flowrates are as follows:
•2 to 2 1/2 GPM for 1100 series units
•2 to 4 GPM for 2200 series units
•2 1/2 to 6 GPM for 3300 series units
G. Hydraulic pressure requirements are as follows:
•2000 to 2500 PSI normal working pressure
•3000 PSI maximum pressure
H. All lifters can be a bolt on type installation for easy, quick maintenance and less
downtime.