Ayrton AYM-07 Manual de usuario

USER MANUAL
AYM-07

This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they are away from the appliance.
DISPOSAL: Do not dispose this product as unsorted municipal waste.
Collection of such waste separately for special treatment is necessary.
R410A(R32/125: 50/50): 1975

Content
Operation Notices
Operation environment...........................................................................................1
Safety warning........................................................................................................1
Part's Name............................................................................................................2
Operation Guide
Operation introduction for control panel .................................................................3
Buttons on remote controller ..................................................................................5
Introduction for icons on display screen .................................................................5
Introduction for buttons on remote controller..........................................................6
Function introduction for combination buttons........................................................8
Operation guide......................................................................................................8
Replacement of batteries in remote controller........................................................9
Maintenance
Clean and Maintenance........................................................................................10
Malfunction
Malfunction analysis .............................................................................................12
Installation Notice
Installation Precaution ..........................................................................................15
Preparation before installation..............................................................................16
Installation
Install drainage pipe .............................................................................................17
Installation and disassembly of heat discharge pipe ............................................18
Operation test.......................................................................................................21
Attached sheet
Drainage way........................................................................................................21
Electric schematic diagram...................................................................................22
Technical specification..........................................................................................23
Used refrigerant....................................................................................................24
Service support, contact.......................................................................................25

1
● The air conditioner must be operated with in the temperature range:16°C ~ 35°C
● The appliance is for indoor use only.
● The appliance must be positioned so that the plug is accessible.
● Reserved space around the air conditioner should be 12″(30cm) at least.
● Do not operate the air conditioner at humid environment.
● Please keep air inlet and air outlet clean, no obstacles.
● During operation, close doors and windows to improve
cooling effect.
● Please put the air conditioner at smooth and flat ground
for operation to avoid noise and vibration.
● This air conditioner is equipped with castors. Castors
should slide at smooth and flat ground.
● Prohibit inclining or turn over the air conditioner. If there’s
abnormity, please disconnect powerimmediately and
contact dealer.
● Avoid direct sunshine.
30cm 30cm
30cm
Operation environment
● Before operation, please confirm whether power specification complies with that on
nameplate.
● Before cleaning or maintaining the air conditioner, please turn off air conditioner and
pull out the power plug.
● Make sure the power cord hasn’t been pressed by hard objects.
● Do not pull or drag the power cord to pull out the power plug or move the air conditioner.
● Do not insert or pull out the power plug with wet hands.
● Please use the grounded power. Make sure the gounding is reliable.
● If the supply cord is damaged, it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a hazard.
● If abnormal condition occurs (e.g. burned smell), please disconnect power at once and
then contact local dealer.
● When nobody is taking care of the unit, please turn it off and remove the power plug or
disconnect power.
● Do not splash or pour water on air conditioner. Otherwise, it may cause short circuit or
damage to air conditioner.
● If use drainage hose, nearby temperature can’t lower than 0°C. Otherwise, it will cause
water leakage to air conditioner.
● Prohibit operating heating equipment around the air conditioner.
● Far away from fire source, inflammable and explosive objects.
● Children and disabled people are not allowed to use the dehumidifier without supervi-
sion.
● Keep children from playing or climbing on the air conditioner.
● Do not put or hang dripping objects above the air conditioner.
● Do not repair or disassemble the air conditioner by yourself.
● Prohibit inserting any objects into the air conditioner.
Safety warning

2
Part's Name
Heat-removal pipe and other installation accessories can't be discarded.
Note:
1
2
3
4
5
1213 11 10
9
6
7
8
Remote controller
1Controller panel
2Guide louver
3Swing louver
4Wheel
5Remote controller box
6Power cord
7Filters
8Upper air inlet grille
9Lower air inlet grille
10 Joint A
11 Heat removal pipe
12 Joint B
13 Joint C

3
Operation introduction for control panel
Name of control panel
ON/OFF buttonMODE button + / - button
fan mode indicator
dry mode indicatorcool mode indicatorsignal receiving window
dual-8 nixie tubewater full indicator
Operation of control panel
Note:
● After putting through the power, the air conditioner will give out a sound. After
that, you can operate the air conditioner by the control panel.
● Under ON status, after each pressing of the button on control panel, the air
conditioner will give out a sound. Meanwhile, corresponding indicator on control
panelwill be bright.
● Under OFF status, dual-8 nixie tube on control panel won’t display.
Under ON status, dual-8 nixie tube on control panel will display set temperature
under cooling mode, while it won’t display under other modes.
Press this button can turn on or turn off the air conditioner.
Under cooling mode, press “+” or “-” button to increase or decrease set temperature
1°C(°F). Set temperature is range is 16°C(61°F)~30°C(86°F). Under auto, drying
or fan mode, this button is invalid.
ON/OFF button
+ / - button
1
2

4
Press this button and the mode will circulate according to below sequence:
COOL→DRY→FAN
when it twinkling, that means the water in the tank is full, we should drain off the
water.
COOL: Under this mode, cooling mode indicator is bright. Dual-8 nix syalpsidebutei
set temperature. Temperature setting range is 16
°C
~30
°C
.
DRY: Under this mode, drying mode indicator is bright. Dual-8 nixie tube won’t be
display.
FAN: Under this mode, the air conditioner only blow fan. Fan indicator is bright.
Dual-8 nixie tube won’t be display.
MODE button
water full indicator
3
4
Operation introduction for control panel
Note:
When the water in chassis is full, the unit will stop operation and the buzzer will
give out eight “beep-beep” sounds for warning. In this case, water full indicator is
blinking (off for 3s and blink for 8 times) and dual-8 nixie tube is displaying “H8”.

5
Buttons on remote controller
Introduction for icons on display screen
21
3
4 5
6 7
1
3
5
2
4
6
7
ON/OFF button
MODE button
+/- button
FAN button
SWING button
SLEEP button
TIMER button
Timer on Timer off
Sending signal
swing operation
sleep operation
lock
set speed
Set timeSet temperature
heat operation
fan operation
dry operation
cool operation
auto operation

6
Introduction for buttons on remote controller
Note:
●
When power is connected(stand by condition), you can operate the air conditioner
through the remote controller.
●
When unit is on, each time you press the button on remote controller, the sending
signal icon " " on the display of remote controller will blink once. If the air con-
ditioner gives out a beep sound, it means the signal has been sent.
● When unit is off, set temperature will be displayed on the remote controller (If the
light of indoor unit display is turned on, the corresponding icon will be displayed);
When unit is on, it will display the icon of the on-going function.
Press this button to turn unit on/off.
ON/OFF button
1
Pressing this button once can select your required mode circularly as below (the
corresponding icon " " will be lit up after the mode is selected):
●
When selecting auto mode, air conditioner will operate automatically according to
ambient temperature. Set temperature can't be adjusted and won't be displayed
either. Press FAN button to adjust fan speed.
● When selecting cool mode, air conditioner will operate under cool mode. Then
press + or - button to adjust set temperature. Press FAN button to adjust fan speed.
● When selecting dry mode, air conditioner will operate at low fan speed under dry
mode. In dry mode, fan speed can't be adjusted.
● When selecting fan mode, air conditioner will operate in fan mode only. Then
press FAN button to adjust fan speed.
● When selecting heat mode, air conditioner will operate under heat mode. Then
press + or - button to adjust set temperature. Press FAN button to adjust fan speed.
(Cooling only unit can’t receive heating mode signal. If set HEAT mode by remote
controller, press ON/OFF button can’t turn on the air conditioner.)
AUTO COOL DRY FAN HEAT
MODE button
2
●
Pressing + or - button once will increase or decrease set temperature by 1°F(°C).
Hold + or - button for 2s, set temperature on remote controller will change quickly.
Release the button after your required set temperature is reached.
● When setting Timer On or Timer Off , press + or - button to adjust the time.(See
TIMER Button for setting details)
+ / - button
3

7
Introduction for buttons on remote controller
Press this button to turn on up&down air swing.
SWING button (not applicable for this model)
5
Under Cool, Heat mode, press this button to turn on Sleep function. Press this button
to cancel Sleep function. Under Fan, Dry and Auto mode, this function is unavailable.
SLEEP button
6
● When unit is on, press this button to set Timer Off. T-OFF and H icon will be
blinking. Within 5s, press + or - button to adjust the time for Timer Off. Pressing
+ or - button once will increase or decrease the time by 0.5h or 1h. Hold + or -
button for 2s, time will change quickly. Release the button after your required
set time is reached. Then press TIMER button to conrm it. T-OFF and H icon
will stop blinking.
● When unit is off, press this button to set Timer On. T-ON and H icon will be
blinking. Within 5s, press + or - button to adjust the time for Timer On. Pressing
+ or - button once will increase or decrease the time by 0.5h or 1h. Hold + or -
button for 2s, time will change quickly. Release the button after your required
set time is reached. Then press TIMER button to conrm it. T-ON and H icon
will stop blinking.
● Cancel Timer On/Off: If Timer function is set up, press TIMER button once to
review the remaining time. Within 5s, press TIMER button again to cancel this
function.
TIMER button
7
Note:
● Under Auto speed, air conditioner will select proper fan speed automatically acc-
ording to ambient temperature.
● Fan speed can't be adjusted under Dry mode.
FAN button
4
Pressing this button can select fan speed circularly as: AUTO, SPEED 1 ( ),
SPEED 2 ( ), SPEED 3 ( ), SPEED 4 ( ) (unavailable in this air conditioner.
Speed 4 is the same with speed 3.).
AUTO
SPEED 1 (equals to low fan speed)
SPEED 3 (equals to high fan speed) SPEED 4
SPEED 2 (equals to medium fan speed)
Tabla de contenidos
Otros manuales de Acondicionador de aire de Ayrton