Warnings and precautions
INTAKE AND
EXHAUST VENTILATORS
The manufacturer recommends consulting the regulator installation guide for connection to the
variable board and the ON / OFF relays.
The manufacturer recommends a maximum of six Avi35 pickups by Gev2 accessory card
amplifier for Genius Itouch.
The manufacturer recommends a maximum of three Avi 35 per variable relay card from a
Genius Itouch controller.
The manufacturer recommends a maximum of five Avi35 per variable relay card from a
MAXIMUS controller.
EXHAUST VENTILATORS must be connected in parallel to a variable relay of the regulator.
Drill the plastic on the side of the shutter to pass the wire. Drill diagonally to reach the plastic
piece that supports the EXHAUST VENTILATOR. Keep enough space to allow the louves to
open without touching the electrical wire. See diagram.
The INTAKE VENTILATORS must be connected in parallel to another variable relay of the
regulator. Drill the upper right corner of the inlet fan housing to pass the wire and probe wire.
The manufacturer recommends using the same common L2 for the 230V solenoid valve of the
wash system, as well as the relay contactors and the AVi35 INTAKE and EXHAUST
VENTILATORS.
The manufacturer recommends installing a bipolar mechanical switch to each fan.
The manufacturer recommends a 3-wire cable to connect the EXHAUST VENTILATOR motor
to the bipolar mechanical switch associated with the EXHAUST VENTILATOR.
The manufacturer recommends a 6-wire cable to connect the INTAKE VENTILATOR motor to
the DPDT relay or the INTERLOCK relays and the bipolar mechanical switch associated with
the INTAKE VENTILATOR.
The manufacturer recommends a 3-wire cable to connect the solenoid valve.
The gauge of the wires must respect the electrical code in force in your area.