Autocall A606-9101 Series Manual de usuario

Foundation Series A606-9101 LCD
Annunciator Installation Guide
579-1434AC Rev B
*05791434ACB*

This page is intentionally blank

Contents 1 Cautions, Warnings, and Regulatory Information.....................................................................................3
2 Introduction................................................................................................................................................... 4
2.1 Compatibility......................................................................................................................................................................................... 4
2.2 Reference documents..........................................................................................................................................................................4
3 Module overview........................................................................................................................................... 5
3.1 Specifications........................................................................................................................................................................................ 7
4 Mounting instructions.................................................................................................................................. 8
4.1 Mounting the Annunciator using the surface mount box.............................................................................................................10
5 Installing the LCD Annunciator..................................................................................................................11
5.1 Configuring the A008 LCD Annunciator...........................................................................................................................................12
5.1.1 Powering the Annunciator in conventional mode...................................................................................................................................12
5.1.2 Annunciator configuration menu.................................................................................................................................................................12
5.1.3 Changing the address of the A008 LCD Annunciator address using the LCD Annunciator......................................................... 12
5.1.4 Changing the language of the LCD Annunciator......................................................................................................................................12
5.1.5 Checking the software version of the LCD Annunciator........................................................................................................................ 12
5.1.6 Changing the display contrast of the LCD Annunciator......................................................................................................................... 12
5.1.7 Changing the display brightness of the LCD Annunciator.....................................................................................................................12
5.2 Configuring A008 FACU for LCD ANN using Panel PC Tool............................................................................................................13
5.3 Configuring A250 and A050 LCD Annunciator using Annunciator UI.......................................................................................... 14
5.3.1 Powering the Annunciator in addressable mode.................................................................................................................................... 14
5.3.2 Enrolling an Annunciator from a A050 or A250 panel............................................................................................................................14
5.3.3 Annunciator configuration options............................................................................................................................................................. 14
5.3.4 Address configuration.....................................................................................................................................................................................14
5.3.5 LCD settings.......................................................................................................................................................................................................14
5.3.5.1 LCD backlight..............................................................................................................................................................................................15
5.3.5.2 LCD contrast............................................................................................................................................................................................... 15
5.4 Configuring A250 and A050 FACUs for LCD Annunciator using PC tool...................................................................................... 16
6 Wiring guidelines.........................................................................................................................................17
6.1 General wiring guidelines..................................................................................................................................................................17
6.2 Specific wiring guidelines.................................................................................................................................................................. 17
6.3 Wire lengths........................................................................................................................................................................................ 17
6.3.1 Calculation of Annunciator wiring distance...............................................................................................................................................17
7 Checkout procedure................................................................................................................................... 19
7.1 Executing the lamp test..................................................................................................................................................................... 19
8 Accessing the user interface......................................................................................................................20
8.1 Enabling access to the user interface.............................................................................................................................................. 20
8.2 Disabling access to the user interface............................................................................................................................................. 20
9 Maintenance................................................................................................................................................ 21
9.1 Cleaning...............................................................................................................................................................................................21

This page is intentionally blank

Foundation Series A606-9101 LCD Annunciator Installation Guide
1 Cautions, Warnings, and Regulatory Information
READ AND SAVE THESE INSTRUCTIONS Follow the instructions in this installation manual. These instructions must be followed to avoid
damage to this product and associated equipment. Product operation and reliability depend upon proper installation.
DO NOT INSTALL ANY AUTOCALL™ PRODUCT THAT APPEARS DAMAGED Upon unpacking your Autocall product, inspect
the contents of the carton for shipping damage. If damage is apparent, immediately file a claim with the carrier and notify an
authorized Autocall product supplier.
ELECTRICAL HAZARD Disconnect electrical field power when making any internal adjustments or repairs. All repairs should
be performed by a representative or an authorized agent of your local Autocall product supplier.
FCC RULES AND REGULATIONS – PART 15
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
page 3 579-1434AC Rev B

2 Introduction
The LCD Annunciator for the A008-9101, A050-9101, and A250-9101 panels provide remote annunciation of the fire alarm control unit
(FACU) status. The LCD display and LEDs indicate the visual status. The piezo sounder provides audible annunciation. You can enable or
lock access to the Annunciator switch functions using the keyswitch, see Accessing the user interface.
You can install a maximum number of four annunciators on the A008-9101 FACU and a maximum number of eight annunciators on the
A050-9101 and A250-9101 FACUs.
Note: From this point on, both the A050-9101 and the A250-9101 FACUs are referred as A250, unless stated otherwise.
2.1 Compatibility
The A008 FACU needs to be at revision 1.07 and the A250 FACU needs to be at revision 1.03 or higher to support the A606-9101 LCD
Annunciator. The LCD Annunciator must be at revision 1.01 or greater when used with A250 and A008 FACUs.
2.2 Reference documents
Refer to the following documents for more information on how to program and use the remote Annunciator.
Table 1: Document reference guide
Document
number
Title
579-1401AC A008 Foundation Series Fire Alarm Control Unit Operation Guide
579-1409AC A004 and A008 Foundation Series Fire Alarm Control Units PC Programmer Installation Guide and Programming
Instructions
579-1404AC A050 and A250 Foundation Series Fire Alarm Control Units Installation Guide
579-1405AC A050 and A250 Foundation Series Fire Alarm Control Unit Operation Guide
579-1421AC A050 and A250 Foundation Series Fire Alarm Control Units PC Programmer Installation Guide and Programming
Instructions
page 4 579-1434AC Rev B
Foundation Series A606-9101 LCD Annunciator Installation Guide

3 Module overview
See Figure 1 for the remote Annunciator front view and see Figure 2 for the back layout.
Figure 1: Remote Annunciator front view
Callout Description Callout Description
A LCD display E RESET
B Up F NAC silence
C Enter G Key switch
D Down H Alarm acknowledgement and buzzer
silence
Figure 2: Remote Annunciator back view
Callout Description
A Mounting screw locations
page 5 579-1434AC Rev B
Foundation Series A606-9101 LCD Annunciator Installation Guide

Figure 3: USB location, Annunciator rear view
Callouts Description
A Screw locations
B USB location
C SW9
Table 2: Remote Annunciator main back components
Components Description
USB port (J1) Use for firmware upgrade. To access the USB port, remove the back plate. For more information contact technical
support.
Address switch SW9.1 Use this switch to select the conventional or addressable FACU for the LCD Annunciator.
CAUTION: After the Annunciator is configured successfully, it is not recommended to change the personality of
the Annunciator from addressable to conventional or conventional to addressable as it will not match the config-
uration settings.
1. To select the Addressable LCD Annunciator:
a. For addressable mode, face SW9.1, then change the position of SW9.1 to the right side, horizontally in
the ON state.
b. Press and hold the RESET key on the Annunciator UI.
c. Apply power to the Annunciator.
d. Wait 5 seconds, then release the RESET key or wait until the Annunciator UI displays the first screen.
2. To select the conventional LCD Annunciator:
a. For conventional mode, face SW9.1, then change the position of SW9.1 to the left side, horizontally in
the OFF state.
b. Press and hold the RESET key on the Annunciator UI.
c. Apply power to the Annunciator.
d. Wait 5 seconds then release the RESET key or wait until the Annunciator UI displays the first screen.
page 6 579-1434AC Rev B
Foundation Series A606-9101 LCD Annunciator Installation Guide

3.1 Specifications
• For use indoors in a dry location.
• All connections are power-limited and supervised.
Table 3: Measurements
Height Length Depth
5 3/8 in. 6 7/8 in. 1 3/8 in.
13.65 cm 17.46 cm 3.49 cm
Table 4: Power requirements and environmental limitations
Measurement type Item Range
Voltage 24 VDC power supply Nominal 24 VDC:
Compatibility range, 16 to 30 VDC
When the LCD back-light is off:
Alarm current: 48 mA
Standby current: 40 mA
Current Maximum current
value
When the LCD back-light is on:
Alarm current: 72 mA
Standby current: 65 mA
Operating range 32°F to 120°F (0°C to 49°C)Temperature
Storage range -4°F to 158°F (-20°C to 70°C)
Humidity Relative humidity The equipment operates normally under non-condensing humidity conditions up to 93%
relative humidity at 90°F (32°C).
page 7 579-1434AC Rev B
Foundation Series A606-9101 LCD Annunciator Installation Guide

4 Mounting instructions
To mount the Annunciator, complete the following steps:
1. Unlock the Annunciator using the B-key provided and press location A to open the backplate as shown in Figure 4.
2. Remove the back plate from housing. To remove the back plate, position the back plate at 90º to the housing as shown in Figure 4 and
then tilt and detach the bottom interface of plate from housing first as shown in Figure 5.
Figure 4: Opening the back plate
See Table in step 3 for callout description.
Figure 5: Detaching the back plate
page 8 579-1434AC Rev B
Foundation Series A606-9101 LCD Annunciator Installation Guide
Tabla de contenidos