AUDAC R2DIS Manual de usuario

R2DIS
User Manual
www.audac.eu

2

3
Index
Introduction 4
Caution servicing 4
User interface 5
Login screen 5
Main screen 7
Zone settings 10
Sound settings 11
Test signals 12
Settings screen 13
Digital input selection 14
Time settings 14
Display configuration 15
Address settings 19
Password settings 20
Factory settings 21
Notes 22

4
Introduction
7” Touchscreen display kit R2
The R2DIS is an optional display unit with touchscreen which can be installed internally
in the front panel of the R2 digital audio matrix system. This unit consists of a 7” TFT
display panel with a resolution of 800 x 480 px that is fitted with a resistive touch-screen
panel. It is controlled by a powerful 32 bit processor which communicates directly with
the DSP processor.
This unit allows the user to operate the control functions of the matrix systems without
any external equipment. This can be useful when the system is installed in a technical
room where no external control devices are within reach.
Touchscreen precautions
• Tap the touchscreen gently. Never use force.
• Don’t use any sharp object to tap the touchscreen. Don’t use a pen, but only
use your fingertips or stylus especially meant for use with touchscreens.
• Keep the touchscreen dry and clean. Don’t use any abrasives or cleaning
solutions to clean it. Only clean it with a soft damp cloth.

5
User interface
Login screen

6
A password should be entered to get access to the R2 amplifier.
There are two different access levels, administrator level and user level.
If you log-in with the administrator password, you get access to all functions and
configuration options. (The factory default password for administrator access is
“R2”).
When you log-in with the user password, you only get access to the basic functions
of the main screen, such as changing the volume and changing the routing for a
particular output zone. (The factory default password for user access is “user”).
After pressing the text field a keyboard screen is displayed, and you can enter the
password.
After the password is entered, press the “OK” button, and you will be redirected to
the main screen of the R2 interface.
NOTE
The passwords can be changed in the Settings >> Password settings menu
(Only administrator)

7
Main screen
The main screen displays all 8 output zones of the R2 with fader volume controls
Volume control:
The volume of each zone can be changed by moving the fader.
At the bottom is a “Mute” button to mute the volume of the corresponding output
zone. If the zone is muted, the mute button is Red. If the zone is unmuted, the mute
button is Green. The mute can be toggled from mute to unmuted by pressing it again.
Assign zone names:
This option is only available if logged in as “ADMINISTRATOR”.
For a better overview of all output zones, every fader has a zone name.
The name of the zone can be changed by pressing and holding the name for 2
seconds. After 2 seconds a keyboard screen is displayed to change the name.
After changing the name, press “OK”.

8
Press the “Save” button and confirm to save the zone settings.
Input channel selection:
This option is available if logged in as “ADMINISTRATOR” or “USER”.
The desired input signal for a zone can be selected by pressing the button below the
zone name. A dropdown list shows 8 audio input signals, together with the options
“Off” and “Other”.
If logged in as administrator, the list can be changed in the “Zone settings” screen.

9
Zone settings:
This option is only available if logged in as “ADMINISTRATOR”.
By pressing the “Settings” button, above a slider, the “Zone Settings” screen is
displayed. In this window you can select the all input channel for the selected zone.
You can also select filters and test signals.
Save:
This option is only available if logged in as “ADMINISTRATOR”.
By pressing this button you can save the settings.
To make sure the changed zone settings are still effective after shutdown and restart
of the R2, the “Save” button on the main screen of the R2 need to be pressed. At the
same time, the volume and routing settings will be saved.
Setup:
This option is only available if logged in as “ADMINISTRATOR”.
In the top right corner is a “Setup” button displayed. After pressing this button, you
will be redirected to the configuration menu of the R2. Info
Info:
Pressing the AUDAC logo will show the info screen.

10
Zone Settings
This option is only available if logged in as “ADMINISTRATOR”.
By pressing the “Settings” button, above a slider, the “Zone Settings” screen is
displayed. In this window you can select an input channel for the selected zone.
Input channel selection:
The screen gives an overview of all input channels that can be patched to the output
zone. You can select “Cinch inputs”, “Wall inputs” , “Fiber inputs”, “No Input” and
“S/PDIF” .
• If “No Input” is selected, the output zone is muted.
• If “S/PDIF” is selected the optical or coaxial input will be routed to the output
zone. (The selection between the optical or coaxial input should be made in the
“Setup Menu” under “Digital Input”).
• If one of the 8 analog “Cinch Inputs” is selected the corresponding RCA
connector input on the rear panel of the R2 is routed to the output zone.
If one of the 8 “Wall Inputs” is selected the corresponding RJ45 PI connector for
Paging or wall input is routed to the output zone.
• If one of the 8 “Fibre Inputs” (Only if the optional R2OPT module is installed) is
selected, a signal from the fibre interconnection interface can be patched to the
selected output zone.