ATN Thermal Entry Wizard Manual de usuario

ATN ATN
Thermal Entry WizardThermal Entry Wizard
TOUCHLESS FEVER DETECTOR
Quick Start Guide
AMERICAN
TECHNOLOGIES
NETWORK
CORP.

2
The instructions in this manual are for informational use only and subject to change without notice,
this manual is not to be construed as a commitment by ATN Corp.
ATN Corp. assumes no responsibility or liability for any errors or inaccuracies that may appear in this book.
©2020 ATN Corp. All rights reserved.

3
APPEARANCE
USB Interface
35.0 mm
25.3 mm
IR Light
IR Light
Touch Screen
Card Presenting Area
White Light
Camera Camera
289.98
116.5 mm
46.0 mm
70.0 mm
239.0 mm
Thermographic Module
IR Light
IR Light
Touch Screen
Card Presenting Area
White Light
Camera Camera
289.98
116.5 mm
46.0 mm
70.0 mm
239.0 mm
Thermographic Module
TAMPER
Wiring
Terminal
Network
Interface PSAM Card Slot (Reserved)
Debugging Port
(for debugging only)
Thermographic
Module
Interface
Power
Interface
NOTE
The figures are for reference only.

4
INSTALLATION
Installation Environment:
• The device should be at least 2
meters away from the light, and
at least 3 meters away from the
window.
• Make sure the environment illumi-
nation is more than 100 Lux.
• Indoor and windless environment
use only.
Steps:
1. Drill holes on the wall or other sur-
face and install the gang box.
2. Connect the thermographic
module and the main body of the
device. Use 5 supplied screws
(4_KA4×22-SUS) to secure the
mounting plate on the gang box.
3
4
4
1&2
3. Align the device with the mounting plate and hang the device on the
mounting plate. Make sure the two sheets on each side of the mounting
plate have been in the slots at the back of the device.
4. Use 2 supplied screws (SC-M4×14.5TP10-SUS) to secure the device and
the mounting plate.
Direct Sunlight
Direct Sunlight
through Window
Indirect Sunlight
through Window
Backlight
Close to Light

5
DEVICE WIRING (NORMAL)
• When connecting door magnetic sensor and exit button, the device and
the RS-485 card reader should use the common ground connection.
• The Wiegand terminal here is a Wiegand input terminal. You should
set the face recognition terminal’s Wiegand direction to “Input”. If you
should connect to an access controller, you should set the Wiegand
direction to “Output”. For details, see Setting Wiegand Parameters in
Communication Settings in the user manual.
• The suggested external power supply for door lock is 12 V, 1A.
• The suggested external power supply for Wiegand card reader is 12 V,
1 A.
• Do not wire the device to the electric supply directly.
• When the screw’s head is beneath the device surface, the device is
secured.
• The installation height here is the recommended height. You can
change it according to your actual needs.
• You can also install the device on the wall or other places without the
gang box. For details, refer to the User Manual.
• For easy installation, drill holes on mounting surface according to the
supplied mounting template.
NOTE
Make sure the output of external power supply fulfills LPS.

6
BTN
Network Interface
Door Contact
(NC)
(COM)
(NO)

7
DEVICE WIRING
(WITH SECURE DOOR CONTROL UNIT)
NOTE
The secure door control unit should connect to an external power
supply separately. The suggested external power supply is 12 V, 0.5 A.
Exit Bu�on
Power Input
SENSOR
BUTTON
B1
B2
B3
B4
Green/Brown
Black
Green/Black
Black
Lock Output
NC C1
C2
C3
COM
NC
White/Purple
White/Black
White/Red
Red
Black Door Contact
Exit Bu�on
NO
Power
Electric
Dropbolt
Electric
Strike
Sensor Input
NO
Face Recognition Terminal Secure Door Control Unit
Secure Door
Control Unit
Wiring Terminal

8
ACTIVATION
IMPORTANT NOTE
Please allow the system to run for 30 min after initial boot up, in order
for it to calibrate itself. Once calibration completes the system will pro-
vide accurate temperature measurement.
Power on and wire the network cable after installation. You should activate
the device before the first login.
If the device is not activated yet, it will enter the Activate Device page after
powering on.
Steps:
1. Create a password and confirm the password.
2. Tap Activate to activate the device.
NOTE
For other activation methods, see the device user manual.
CAUTION
Strong password recommended!
We highly recommend you create a strong password of your own
choosing (using a minimum of 8 characters, including upper case let-
ters, lower case letters, numbers, and special characters) in order to
increase the security of your product. And we recommend you reset your
password regularly, especially in the high security system, resetting the
password monthly or weekly can better protect your product.
TEMPERATURE MEASUREMENT
SETTINGS
1. Hold the screen surface and verify the identity to enter the main page.
2. Tap “Temperature” to enter the Temperature Settings page. Configure the
parameters.
• Enable Temperature Detection
When enabling the function, the device will authenticate the permissions
and at the same time take the tempearture. When disabling the device, the
device will authenticate the permissions only.
• Over-Temperature Alarm Threshold
Edit the threshold according to actual situation. If the detected temperature
is higher than the configured one, an alarm will be triggered. By default, the
value is 99.14°F.
• Door Not Open When Detecting Abnormal Termperature
When Enabling the function, the door will not open when the detected tem-
perature is higher than the configured temperature threshold. By default, the
temperature is enabled.
• Temperature Measurement Only
When enabling the function, the device will not authenticate the permis-
sions, but only take the temperature. When disabling the function, the device
will authenticate the permsissions and at the same time take the temperature.

9
ADDING FACE INFORMATION
1. Hold the screen surface and verify the identity to enter the main page.
2. Enter the User Management page, tap + to enter the Add User page.
3. Set the user parameters according to actual needs.
4. Tap Face and collect the face information according to the instructions.
You can view the captured picture at the upper right corner of the page.
Make sure the face picture is in good quality and size. For details about
the tips and positions when collecting or comparing the face picture, see
the contents on the right.
5. If the picture is in good condition, tap Save to save the picture. Or tap Try
Again to take another face picture.
6. Tap to save the settings. Go back to the initial page to start authenti-
cation. For other authentication methods, see the device user manual.
Use other authentication methods if the device is affected by the light or
other items.
NOTE
Biometric recognition products are not 100% applicable to anti-spoof-
ing environments. If you require a higher security level, use multiple
authentication modes.
TIPS WHEN COLLECTING/
COMPARING FACE PICTURE
Expression
• Keep your expression naturally when collecting or com-
paring face pictures, just like the expression in the picture
on the right.
• Do not wear hat, sunglasses, or other accessories that
can affect the facial recognition function.
• Do not make your hair cover your eyes, ears, etc. and
heavy makeup is not allowed.
POSTURE
In order to get a good quality and accurate face picture, position your face
looking at the camera when collecting or comparing face pictures.
Correct Tilt RaiseSide Bow
• Measurement Area Calibration/Measurement Area Settings
Configure the temperature measurement area and the correction parame-
ters.

10
SIZE
Make sure your face is in the middle of the collecting window.
Correct Too Close Too Far
POSITIONS WHEN COLLECTING/
COMPARING FACE PICTURE
(Recommended Distance: 0.5 m)
1.4m
0.5m
1.4m
Too High
Too Low
Too Close Too Far
1.4m
1.2m
1.4m
0.5m 0.5m
Recommended Height:
1.43m to 1.90m