Atim Cloud Wireless ACW/LW8-CTS Manual de usuario

Atim Cloud Wireless®
Current temperature sensor
User guide
Models concerned :
ACW/LW8-CTS

2
ATIM_ACW-CTS_UG_EN_V1.1
Table of contentss
THIS USER GUIDE APPLIES TO THE FOLLOWING REFERENCES ............................................. 4
VERSION HISTORY OF THIS DOCUMENT ............................................................................. 4
DISCLAIMER .....................................................................................................................5
TRADEMARKS AND COPYRIGHTS ....................................................................................... 5
DECLARATION OF CONFORMITY ........................................................................................ 5
ENVIRONMENTAL RECOMMENDATIONS .............................................................................. 6
A. ENVIRONMENT ..........................................................................................................................................................6
B. RADIO .................................................................................................................................................................... 6
TECHNICAL SPECIFICATIONS ............................................................................................. 7
A. PRODUCT ................................................................................................................................................................ 7
B. INTEGRATED SENSOR FUNCTIONS ................................................................................................................................. 7
BOX .................................................................................................................................7
A. DIMENSIONS ............................................................................................................................................................ 8
B. INSTALLATION ...........................................................................................................................................................8
C. IDENTIFICATION .........................................................................................................................................................9
OPERATING PRINCIPLE ..................................................................................................... 9
A. ENERGY RECOVERY ....................................................................................................................................................9
B. OPERATING DIAGRAM ...............................................................................................................................................10
ACW CONFIGURATOR ......................................................................................................12
A. COMPATIBLE CONFIGURATOR VERSIONS ....................................................................................................................... 12
B.EGREENSENSOR CONFIGURATION ............................................................................................................................... 13
Transmission period and frame samples ............................................................................................................13
Communication interface ................................................................................................................................... 15
Frame timestamp ...............................................................................................................................................15
Radio module configuration ............................................................................................................................... 16
Product clock ......................................................................................................................................................17
Product versions .................................................................................................................................................17
Sensor configuration .......................................................................................................................................... 18
Thermocouple activation .......................................................................................................................................................18
Threshold Temperature, current and voltage .......................................................................................................................18
Current and temperature measurement calibration ............................................................................................................ 18
Real-time measurement display ........................................................................................................................................... 18
Configuration validation ........................................................................................................................................................ 18
C. FACTORY SETTINGS ................................................................................................................................................. 19
D. ACW UPDATE ........................................................................................................................................................ 20
UPLINK FRAME FORMAT ................................................................................................. 21
A. DESCRIPTION ......................................................................................................................................................... 21
Classic frame ......................................................................................................................................................21
The different types of frame .............................................................................................................................. 22
Measurement frame ...........................................................................................................................................22
Measurement alert frame ...................................................................................................................................24
Error and general alarm frame ...........................................................................................................................25
B. EXAMPLE FRAMES ....................................................................................................................................................27
Measurement frame ...........................................................................................................................................27
Measurement alert frame ...................................................................................................................................29
DOWNLINK .....................................................................................................................30
A. PARAMETER MODIFICATION ........................................................................................................................................31
B. SEND DOWNLINK COMMAND. ..................................................................................................................................... 33

4
ATIM_ACW-CTS_UG_EN_V1.2
This user guide applies to the following references
Version history of this document
Version
Date
Description
Author
Software
version
concerned
/Revision
1.2
07/12/2023
Correction of exemple frame errors
YL
V1.0.7 / A1
1.1
25/09/2023
Patches
FR
V1.0.5 / A0
1.0
27/09/2022
Document creation
YL
V1.0.5 / A0
Product references
Product version
(Visible on product label)
LoRaWAN
ACW/LW8-CTS
A1

5
ATIM_ACW-CTS_UG_EN_V1.2
Disclaimer
The information contained herein is subject to change without notice and does not represent a
commitment on the part of ATIM radiocommunications. ATIM radiocommunications provides this
document "as is" without warranty of any kind, either expressed or implied, including, but not limited to,
the implied warranties of merchantability or fitness for a particular purpose. ATIM radiocommunications
may make improvements and/or changes in this manual or in the product(s) and/or program(s)
described in this manual at any time.
Trademarks and copyrights
ATIM radiocommunications®, ACW ATIM Cloud Wireless®, ARM Advanced Radio Modem® are registered
trademarks of ATIM Sarl in France. Other trademarks mentioned in this document are the property of
their respective owners.
Declaration of conformity
All ACW (Atim Cloud Wireless®) products comply with the regulatory requirements of R&TTE Directive
1999/5/EC Article 3 :
1 Safety (Article 3.1a of Directive 1999/5/EC)
NF EN60950-1 Ed. 2006/A1:2010/A11:2009/A12:2011 (health)
EN62479: 2010 (power <20mW) or EN62311:2008 (power > 20mW)
2 Electromagnetic compatibility (Article 3.1b of Directive 1999/5/EC)
EN 301489-3 v1.4.1, EN 301489-1 V1.9.2
3 Efficient use of the radio frequency spectrum (Article 3.2 of Directive 1999/5/EC)
ETSI EN300 220-2 v2.4.1 and EN300 220-1 v2.4.1

6
ATIM_ACW-CTS_UG_EN_V1.2
Environmental recommendations
a. Environment
Observe the product's storage and operating temperature ranges. Failure to do so could disrupt
operation and even damage the equipment.
This equipment is not designed for outdoor use!
Follow the precautions and instructions below to ensure your safety and that of your environment, and
to prevent damage to your equipment.
General danger - If the instructions are not followed, there is a risk of damage to equipment.
WARNING : do not install near heat or moisture.
This symbol on the product or its packaging indicates that this product must not be disposed of
with your other household waste. Instead, it is your responsibility to dispose of your waste by
taking it to a designated collection point for the recycling of electrical and electronic appliances.
Separate collection and recycling of your waste at the point of disposal will help conserve natural
resources and ensure recycling that respects the environment and human health. For more
information on your nearest recycling center, contact your local town hall, your household waste
disposal service or the store where you bought the product.
b. Radio
The modems in the ACW range are part of the radiocommunication modems using the ISM (Industrial
Scientific Medical) bands, which can be used freely (free of charge and without authorization) for
industrial, scientific and medical applications.

7
ATIM_ACW-CTS_UG_EN_V1.2
Technical specifications
a. Product
Antennas
Integrated (¼ wave)
Temperature
-20°C to +55°C (operating)
-40°C to +70°C (storage)
Power
None (energy recovery)
Weight
130g
Frequency
863 – 870 MHz
Power
25 mW (14 dBm)
Radio version
Sigfox : NA
LoRaWan : v1.0.4
Flow
Sigfox : NA
LoRaWAN : 250 bit/s à 5.5 Kbit/s
Consumption
Sigfox
LoRaWAN
Tx mode
NA
30 mA
Watch
NA
19 µA (sans BLE)
52µA (avec BLE)
Rx mode
NA
5 mA
b. Integrated sensor functions
Current sensor
Range
0A to 200ARMS
Resolution
0,01A
Precision
Class 1
Thermocouple (optional remote sensor)
Range
-200°C to 1200°C
Resolution
0,1°C
Precision
3%
Box

8
ATIM_ACW-CTS_UG_EN_V1.2
a. Dimensions
Dimensions in mm
b. Installation
1. Open the sensor's movable
jaw by lifting the tab on the side
of the sensor.
2. Position the sensor so that the
conductor passes between the
two legs of the magnetic circuit.
3. Close the movable jaw again
until the tongue snaps into place
on its catch.
CLIC

9
ATIM_ACW-CTS_UG_EN_V1.2
c. Identification
The product's LoRaWAN identifier is printed on the sensor and in the status bar of the ACW configurator.
It can also be read by scanning the QR-Code.
For LoRaWAN modems, the communication keys are automatically given by the network (pairing by
"Over The Air Activation", or OTAA).
Operating principle
a. Energy recovery
As this is a stand-alone product, it needs a certain amount of time to store enough energy to be able to
start up, particularly on first use when the storage element is empty.
The minimum current required to start drawing energy is 2ARMS. The graph and table below give the
charging times for different currents in the phase conductor for cold start.

10
ATIM_ACW-CTS_UG_EN_V1.2
For currents above 40ARMS, charging time does not drop below 10mn.
In normal operation, if the line current drops below 1ARMS, the energy recovery stage is deactivated.
The sensor will continue to operate on stored energy for approximately 30 minutes.
When the current in the phase is restored, the time required to restart is given by the graph below :
In continuous operation, a line current of amplitude 1.2ARMS is sufficient to supply the transducer with
the energy required by the system without using the energy stored in the storage element.
b. Operating diagram
Simplified block diagram :
Tabla de contenidos