AQUAMAX® BASIC/CLASSIC
Operating Instructions

Important information for consumers in the EU
Disposal instructions for batteries and rechargeable batteries
Every consumer is legally obliged to return all used batteries and
rechargeable batteries according to the Battery Ordinance (Directive
2006/66/EC). Disposal in the household waste is prohibited. Since
batteries and rechargeable batteries are also included in the delivery of
products from our range, we would like to point out the following:
Used batteries and rechargeable batteries do not belong in the
household waste, but can be handed in free of charge at the public
collection points of your municipality and everywhere where batteries
and rechargeable batteries of the respective type are sold.
Furthermore, the end user has the option of returning batteries and
accumulators to the retailer from whom they were purchased (statutory
take-back obligation).
Disposal of electronic equipment
Due to the European Regulation 2012/19/EU, your electronic device
must not be disposed of with normal household waste! We will dispose
of your electrical equipment in a professional and environmentally
responsible manner. This service is free of charge, not including
transport costs. This service only applies to electrical appliances
purchased after 13.08.2005. Send the appliance you want to dispose
of to your supplier free of charge.

Operating instructions AQUAMAX® BASIC/CLASSIC
ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com /
Art.-No.: 9060 0270 / Status: 09.06.2023 / Page 3 from 36
Contents
General and safety information…………………………… .......................................... 4
Functional description ........................................................................................ 6
Control unit ATBcontrol© 3 - Connect ..................................................................... 8
General information on operation .................................................................... 9
Commissioning .............................................................................................. 10
Main level ...................................................................................................... 12
Logbook .................................................................................................... 12
Settings ..................................................................................................... 13
Service Mode ............................................................................................. 15
Manual operation / Info .............................................................................. 16
Date/Time / Language / Error Reset ............................................................ 17
Pre-set Parameters ........................................................................................ 18
Current limiting values ................................................................................... 19
Error messages ............................................................................................. 19
UVS® ............................................................................................................ 19
Control Circuit Board / Fuses .......................................................................... 20
Potential-free Contact .................................................................................... 20
Configuration of the Connection Socket ........................................................... 21
USB-connection ............................................................................................. 21
Technical Data .............................................................................................. 22
Mobile Access via WiFi-Direct ........................................................................ 23
Information on routine maintenance .................................................................... 23
Rectification of faults ......................................................................................... 24
Important data for fault diagnosis of the electrical units ....................................... 26
EC Declaration of Conformity ............................................................................. 27

Operating instructions AQUAMAX® BASIC/CLASSIC
ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com /
Art.-No.: 9060 0270 / Status: 09.06.2023 / Page 4 from 36
Dear customer,
At this point we would like to thank you for the trust which you have shown with the purchase of
this product.
On the following pages you will find everything necessary about the ioperation and the
maintenance requirements of your AQUAMAX® small wastewater treatment plant.
Please observe that the maintenance are very important for a good treatment performance.
General and Safety Information
With the AQUAMAX® one is concerned with a technical system which, in combination with a multi-
chamber tank, is employed as small wastewater treatment plant for the aerobic biological treatment
of domestic and comparable wastewater of up to 75 PE from single or several buildings.
Dimensioning, design and operation are to take place up to 50 PE in accordance with EN 12566-3.
With employment in accordance with regulations no hazards whatsoever emanate from the plant. If
the AQUAMAX® is used for other purposes without the explicit approval of ATB WATER GmbH
and/or the following safety information is ignored, this can lead to the hazarding or injury of
persons and to malfunctions or defects in the plant. In this case any liability is excluded,
Modifications to the plant or unauthorized conversion is not permitted.
The AQUAMAX® and accessories are not intended to be used by persons (including children) with
limited physical, sensory or mental capabilities or due to a lack of experience and/or knowledge,
unless they are supervised by or receive instruction from a person responsible for their safety, as
to how the AQUAMAX® and accessories are to be used. Children are to be supervised in order to
ensure that they do not play with them.
Before use the AQUAMAX® is to be installed correctly and in agreement with the installation
instructions. Installation instructions, operating and maintenance instructions are to be read
thoroughly and the instructions included therein are to be followed implicitly.
With assembly and installation, commissioning and operation as well as, if required,
decommissioning, national standard specifications and regulations are to be complied with. All
tasks may be carried out by trained and qualified specialists with appropriate certificate of technical
qualification. The operator is to be instructed by the fitter.
With the connection of the control system the national applicable regulations and the details on the
type plate are to be complied with (mains voltage, frequency etc.). The equipment is to be operated
on a network which includes a protective earth conductor (PE). Attention is to be paid to correct
phase connection (even with plug-in design)! The connection to the mains must take place by
means of separate fusing and residual current protective circuit breaker. Before commissioning,
the correct function of the electrical protective measures must be checked!
The installation work is to be carried out by qualified electricians only. With work on the equipment
fundamentally the mains plug is to be disconnected. A separation or extension of the cable is not
permitted. The electrical connection data is to be taken from the type plate on the equipment.
Operate no equipment which has a damaged connector/connection cable or plug, which indicates
a malfunction, has been dropped or has been damaged in any way.
With all maintenance and repair work the plant is to be disconnected from the mains. The
AQUAMAX® can be removed easily from the tank. If the plant is to be climbed into, this may take
place only with the presence of a second person (this is fundamental!). Particular care is to be

Operating instructions AQUAMAX® BASIC/CLASSIC
ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com /
Art.-No.: 9060 0270 / Status: 09.06.2023 / Page 5 from 36
taken. The applicable accident prevention regulations and rules of technology are to be complied
with.
In the versions with submersible aerator the AQUAMAX® feeds the required air to the wastewater
through a rapidly rotating propeller. Never work in the vicinity of the aerator as long as the
AQUAMAX® is connected with the mains. Danger of injury!
The correct function can only be guaranteed with the employment of original spare parts or spare
parts approved by ATB. Before commissioning, all points of the operating instructions are to be
checked. Keep these instructions readily to hand at all times!
Explanation of the warning notices used:
Attention! Danger due to electrical voltage!
Rotating parts. Danger of crushing and being drawn into the area of the submersible aerator!
The ATBcontrol© 3 Connect is delivered as a ready-to-plug-in version. There is no need for wiring
on site.
ATTENTION! Before opening the ATBcontrol© 3 – Connect and/or the connection
box it/they must be disconnected from the mains supply. Work on opened units
may be carried out exclusively by qualified electricians! Pay attention to phase-
correct connection (even with plug-in design)!
As you are concerned with an electrical plant with submerged motor units, a
separate B16 fuse and a (separate) upstream 30 mA ELCB (earth leakage circuit
breaker) is absolutely essential!
Attention is to be paid to correct laying of the protective earth conductor up to the
earthing of the building.
Make sure that no damage to persons, material or downstream equipment can
occur, especially during the manual commissioning of units (manual operation)!

Operating instructions AQUAMAX® BASIC/CLASSIC
ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com /
Art.-No.: 9060 0270 / Status: 09.06.2023 / Page 6 from 36
Functional Description
The wastewater treatment plant works according to the activated sludge principle using the
retention process (single tank or SBR plant). With this, the contaminants from the wastewater are
taken up by suspended micro-organisms (activated sludge) and converted into biomass.
The wastewater first reaches the coarse interceptor. Every 2 hours – according to the principle of a
communicating pipe and with the aid of an excess sludge pump – the retained wastewater is fed
into the aeration stage. The aeration takes place intermittently via a submersible motor aerator or
with a compressor and membrane tube diffusers on the tank bottom (CLASSIC ZB).
After 6 hours the aeration phase ends and the settling phase begins.
After 2 hours settling time the treated wastewater is pumped out using the clarified water pump.
The switch-off point is determined via a float switch. If, as a result of a pump defect, this minimum
water level is not achieved an alarm is triggered. After ca. 8 hours, with the end of the clarified
water removal, the cycle is ended and a new one begins.
The control unit can be matched to the respective requirement case. With commissioning the plant
is set to the maximum number of persons connected. A modification of this setting is not required
with short-term over or underloading.
The plant achieves its full treatment performance after a run-up period of ca. one month. With more
extreme underloading or temperatures under 12° C it can also take longer until the biology has
developed completely. In this case it is recommended to seed using activated sludge in order to
accelerate matters.
With the AQUAMAX® BASIC charging, removal of excess sludge and the drawing off of clarified
water take place using only one pump. The water streams with this are fed into the individual areas
using a patented hydraulic system.
*alternatively membrane tube diffuser on the tank bottom
*

Operating instructions AQUAMAX® BASIC/CLASSIC
ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com /
Art.-No.: 9060 0270 / Status: 09.06.2023 / Page 7 from 36
Holiday / energy-saving operation
If, over a period of more than 4 hours, no wastewater flows into the plant, then the system switches
automatically into the energy-saving holiday operation. The aeration time is reduced to the point
that the micro-organisms just have sufficient oxygen available. With normal loading the plant
switches back into the operating mode set.
Sampling
As the pumping out process is of a short duration only, the treated water is collected into a suitable
container in the filtering tank (accessory: 1.5 l sampling bottle). The container is mounted in the
vicinity of the cover and is thus easily accessible from above.
Alternatively a container can be deployed in a separate sampling shaft.
Installation and dimensioning
Dimensioning and statutory installation conditions are described in more detail in the German
National General Technical Approval.
Operation and maintenance
Small wastewater treatment plants must be checked by the operator at certain intervals as well as
being serviced twice a year by a specialist. Both are important for a correct operation of the plant.
The sludge removal of the primary settling stage takes place, depending on utilisation, once a year
or as required.
Further details on this can be taken from the corresponding chapter.
Application possibilities
The AQUAMAX® is conceived for the treatment of domestic wastewater. The following may not be
fed to the small wastewater treatment: commercial/trade wastewater (insofar as it is not
comparable with domestic), infiltration water (e.g. drainage water), cooling water, runoff water from
swimming pools, precipitation water.
Technical data
The AQUAMAX® consists of the following electrical units:
1 (BASIC) or 2 submersible pump(s)
1 or 2 submersible motor aerator(s)
or compressor(s)
1 float switch
1 control unit
The units are designed for 230V, 50 Hz.
In addition, the AQUAMAX® consists of a carrier frame, pipelines and hoses.
The electrical components are subjected to systematic wear. In individual cases these components
must be exchanged after 2 years. The service life of the units, from experience, lies between 5 and
10 years.
Treatment performance
The AQUAMAX® meets the following limiting values (with standard conditions and correct
operation):
BOD5: 20 mg/l
COD: 90 mg/l
NH4N (>12°C): 10 mg/l
Ntot: 25 mg/l (>12°C)

Operating instructions AQUAMAX® BASIC/CLASSIC
ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com /
Art.-No.: 9060 0270 / Status: 09.06.2023 / Page 8 from 36

Operating instructions AQUAMAX® BASIC/CLASSIC
ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com /
Art.-No.: 9060 0270 / Status: 09.06.2023 / Page 9 from 36
Control unit ATBcontrol© 3 - Connect
Features
Features
Microprocessor controlled
USB connection for data readout and input
Splash water protected. Conditionally suitable for outside areas (IP54)
Wall mounting
Voltage failure detection system (UVS®)
Floating contact for an additional alarm facility
Simple and rapid operation
Times for all parameters completely pre-programmed
Automatic run-in phase with suppression of excess sludge removal
Parameter settings freely selectable
Alarm interval
Alarm volume adjustable
Deployable for AQUAMAX® BASIC / CLASSIC
Plug-in
Winter operation and sludge removal mode for the reduction of the aeration times
Mobile access via internet browser (e.g. with smartphone or tablet) via WiFi-Direct
General information on operation
The operation of the control unit takes place via three short-stroke keys. By pressing a key the
display illumination is switched on (lapses if no key is operated within 5 minutes).
Key functions:
↑↓ Scroll upwards or downwards / menu selection
OK Transition of cursor to the character, which is to be changed / value input is saved /
selection of menu point / menu setback.
With temperatures below 0°C a severely limited function of the LC display is to be anticipated.

Operating instructions AQUAMAX® BASIC/CLASSIC
ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com /
Art.-No.: 9060 0270 / Status: 09.06.2023 / Page 10 from 36
Commissioning
With first commissioning basic settings and tests are carried out. Please ensure that all information
for this is available. With input of the plant values all important parameters are pre-set. However,
we recommend that, following commissioning, the parameters are again checked under
Settings, as false values can, inter alia, lead to an increased power consumption.
In the Service Mode you have the possibility later of undertaking modifications.
Language selection
Enter language you need. German, English, French, Italian, Romanian,
Polish, Slovenian, Spanish, Dutch are available.
Password input
Please enter the six-figure code number.
Date and time
Enter the date and time.
Important for the correct entries in the logbook
Selection of the plant type
Select between BASIC or CLASSIC.
Number of inhabitants
Select the connected PT.
The settings belonging to the number of inhabitants are carried out
automatically.
Serial number
Here you enter the serial number that is located on the sewage treatment
plant. Please make sure to enter the serial number right-justified so that there
are leading zeros.
The SSID of the control unit is also defined with the entry (for mobile access
via WiFi Direct). The SSID should be assigned "systematically". If not the
system serial number (preferably), then e.g. the serial number of the control unit. A subsequent
change is possible in the settings.
(
=WiFi-No.-endin
g)
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Sistema de filtración de agua de ATB