ASURITY FP-22 Manual de usuario

Installation Instructions
Models: FP-22, FP-22-230
Acidic & High
Temperature Applications
Condensate
Pump Specialty

ASURITYTM
CONDENSATE MANAGEMENT PAGE 2
INTRODUCTION
SAFETY INFORMATION
Please read, understand, and follow all safety instructions. Failure to follow
instructions may result in property damage, serious injury, or death.
DANGER
ALWAYS disconnect power prior to moving, adjusting, or servicing
pump or attached systems. DO NOT use this pump in the presence of
spraying or standing water. Failure to do so could result in a fatal electric
shock.
WARNING: FIRE AND EXPLOSION HAZARD
DO NOT use this pump to move ammable or explosive liquids. DO
NOT use this pump in explosive or ammable environments.
Carbon monoxide hazard. Ensure that pump is mounted away from heat
exchanger or wiring. If you are unsure of any items in this manual, please
consult a professional and DO NOT attempt to install this product.
CALIFORNIA PROPOSITION 65
This product may contain chemicals known to the state of California to
cause cancer, birth defects, or other reproductive harm. Wash hands
after handling this product.
CAUTION: FLOOD RISK
Personal injury or property damage can result from an inoperative
pump. If a ood has occurred, DO NOT walk in wet area until all power
has been turned o. Check with local electric company or a qualied
electrician before disconnecting any electrical service prior to pump
removal.
WARNING
Pump must be properly wired to condensate producing appliance control
board in order to shut o appliance in alarm (high water) conditions.
Supply voltage and frequency must match what is shown on pump
nameplate. Source voltages lower than the rated supply can reduce
performance and cause pump to overheat.
Pump must be level or should be placed on a solid surface or oor.
DO NOT cover pump air vents. Pump is air cooled. DO NOT cover vent
holes located on top or sides of the pump housing. Pump may be
operated continuously as long as air vents are not covered.
Pump should be stored indoors. The chosen location should be clean
and dry.
This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of

www.diversitech.com | 800.995.2222 PAGE 3
experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play
with the appliance.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualied persons in order to avoid a hazard.
TEMPERATURE RATING
• Continuous duty 170˚F
• Max inlet temperature 190˚F
• Not suitable for contact with steam or gases that exceed 190˚F.
GENERAL INFORMATION
This pump is designed to automatically remove the condensate water that
collects from appliances such as air conditioners, high-eciency furnaces,
and de-humidiers. The pump has a built-in tank that collects water from
the appliance. When water collected reaches sucient level inside pump
tank, pump switches on and pumps water to a remote location for disposal.
When tank is suciently empty, pump automatically switches o. Pump is
capable of lifting water up to 22 ft. and is equipped with a check valve that
prevents water from owing back into tank when pump shuts o.
The pump utilizes LED lights that show the status of Power Available, Motor
Running, and High Water (Alarm) Conditions. Pump is also equipped with a
switch that activates when water in tank reaches an overow condition. The
overow safety switch may be connected to turn o the appliance if high
water condition occurs.
FEATURES
POWER
Metal Hang Tabs
Lengüetas colgantes
de metal
LED Indicator Lights
Luces indicadoras con
bombilla LED
Inlet Hole
Orificio de entrada
Inlet Hole Cover
Cubierta
Overflow Safety Switch
Interruptor de seguridad
de rebose
Check valve - 1/4 Turn
Removable
Válvula de retención -
Removible con ¼ de giro
Integrated P-Traps in
Corners
Siphons en “P” intégrés
dans les coins
Chemical + Temperature Resistant Tank
Tanque resistente a la temperatura y a los químicos

ASURITYTM
CONDENSATE MANAGEMENT PAGE 4
PACKAGE CONTENTS
SPECIFICATIONS
PART DESCRIPTION QUANTITY
A Condensate Pump 1
B Inlet Hole Covers 3
C Wires with Pre-crimped connectors 1
FP-22 FP-22-230
Rated Voltage 120 Volts/60Hz 220 Volts/60 Hz
Rated Current Draw 1.9 Amps 1.0 Amps
Head Height 22 ft. maximum 22 ft. maximum
Flow Rate at Zero
Head
1.6 GPM 1.0 GPM
Product Weight 4.8 lbs. 5.2 lbs.
Inlet Height from Base 4.3" 4.3"

www.diversitech.com | 800.995.2222 PAGE 5
INSTALLATION
MOUNTING OPTIONS
1A. PLACE ON FLOOR
Determine condensate pump location.
1B. ATTACH TO WALL
Attach condensate pump with screws (8” between mounting tabs).
OPTION: REVERSE TOP IF
NECESSARY
Pump top may be rotated 180˚
to allow access to pump outlet
or power connection.

ASURITYTM
CONDENSATE MANAGEMENT PAGE 6
INSTALLATION (continued)
2. LEVEL UNIT
Ensure that condensate pump is level.
OUTLET CONNECTIONS
3. INSTALL OUTLET TUBE CONNECTION
Attach plastic tubing to check valve and secure with hose clamp. Route
tubing up and away from condensate pump (avoid compressing or
kinking tubing).

www.diversitech.com | 800.995.2222 PAGE 7
INSTALLATION (continued)
INLET CONNECTIONS
4. INSTALL INLET TUBE CONNECTIONS
Install condensate drain tubing into one of the four inlet holes, making
sure tubing is straight.
If installing to a humidier, a
“P” trap should be used.
INLET COVERS
5. INSTALL INLET COVERS
Insert inlet covers in remaining condensate pump inlet holes.

ASURITYTM
CONDENSATE MANAGEMENT PAGE 8
INSTALLATION (continued)
6. SAFETY SWITCH CONNECTION
Connect overow safety switch terminals as shown in wiring diagram.
WARNING: RISK OF ELECTRIC SHOCK
Ensure that power to appliance and pump is shut o before
attempting this step! Failure to follow these warnings will void the
warranty and could result in a fatal electric shock.
Com
Run
RUN
Shut-Down Circuit*
Shut-Down Circuit*
*Overflow Switch is normally
closed and opens when a
high water level is detected.
Connect this circuit in series
with the appropriate 24V
shut-down circuit for the
appliance.

www.diversitech.com | 800.995.2222 PAGE 9
INSTALLATION (continued)
ELECTRICAL CONNECTION
7. ELECTRICAL CONNECTION
WARNING: RISK OF ELECTRIC SHOCK
This pump must be properly connected to power following the
National Electric Code (NEC). Failure to follow these warnings will void
warranty and could result in a fatal electric shock. A green LED will
indicate if power is available.
This pump is supplied with a grounding conductor and grounding
type attachment plug. To reduce the risk of electric shock, be certain
that it is connected only to a properly grounded, grounding-type
receptacle.
PLUG NOTE: REMOVAL OF THE WALL SIDE ELECTRICAL PLUG MAY
BE PERMISSIBLE IF:
1. The power leads, after plug removal, are connected directly within an
approved junction or conduit box, as judged by the local authority having
jurisdiction.
2. The modication is performed by a qualied technician.
3. The modication meets code compliant requirements according to the
local authority. This modication does not void the factory warranty. Final
installations should always be inspected and approved by the local
authority according to the requirements set forth by the same local
authority.

ASURITYTM
CONDENSATE MANAGEMENT PAGE 10
OPERATION
1. TESTING FLOAT
Manually ll the tank with water. An amber LED will indicate pump is
operating.
2. TESTING OVERFLOW SWITCH (IF CONNECTED)
Manually overll tank with water. If overow safety switch is wired
correctly, appliance will shut down, condensate pump will pump out
water, and a red LED will illuminate.
2
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Idiomas:
Otros manuales de Bomba de agua de ASURITY
Manuales populares de Bomba de agua de otras marcas

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guía de solución de problemas

DUROMAX
DUROMAX XP WX Series Manual de usuario

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manual de usuario

Franklin Electric
Franklin Electric IPS Manual de usuario

Xylem
Xylem e-1532 Series Manual de usuario

Milton Roy
Milton Roy PRIMEROYAL Manual de usuario