ASP Sterrad Velocity Reader Manual de usuario

User’s Guide
AB11321031
AB11321031-50 January 2021.
© ASP 2021. All rights reserved.
Reader

STERRAD VELOCITY™Reader
User’s Guide
AB11321031
1-888-STERRAD (USA only) or 949-581-5799
ASP Professional Services
ASP International Customer Support
(Call your local ASP Customer Support Representative)
www.asp.com
For warranty information, please visit our website or contact ASP Professional Services.
© ASP 2021. All rights reserved. STERRAD VELOCITY™, ASP ACCESS™ and ALLClear™ are trademarks of
Advanced Sterilization Products, Inc. (ASP). STERRAD™ and STERRAD NX™ are registered trademarks
of Advanced Sterilization Products, Inc. (ASP). Other products mentioned in this publication are
trademarked by their respective owners. Reproduction, adaptation, or translation of this publication
without prior written permission is prohibited. Printed in the U.S.A.
33 Technology Drive, Irvine, CA 92618, USA
ADVANCED STERILIZATION PRODUCTS, INC.
ASP, The Netherlands BV
BIC 1, 5657 BX, Eindhoven, The Netherlands

STERRAD VELOCITY Reader User’s Guide iii
Contents
Chapter 1. Introduction.............................................................................. 1
How to Use This Guide .........................................................................................1
Intended Use ........................................................................................................1
Indications for Use...............................................................................................2
Product Description .............................................................................................2
If You Have Questions ..........................................................................................2
Chapter 2. SafetyInformation................................................................... 3
Symbols ................................................................................................................3
Warnings, Cautions, and Notes...........................................................................5
Chapter 3. Overview...................................................................................9
The STERRAD VELOCITY Reader and Features..................................................9
Before You Start ..........................................................................................10
Start and Warm-up.....................................................................................10
The Status Screen.......................................................................................11
System Status Indicator.............................................................................12
Biological Indicators ...................................................................................12
Biological Indicator Wells...........................................................................13
Sleep Mode..................................................................................................14
Touch Screen ...............................................................................................14
Barcode Scanner.........................................................................................14
Power Adapter.............................................................................................14
Chapter 4. Operation................................................................................ 15
Instructions for Use ...........................................................................................15
Process Description...........................................................................................15
Warm-up......................................................................................................15
Adding a Positive Control BI .......................................................................15
Adding a Test BI ...........................................................................................19
Manual Entry of Cycle Information............................................................21
In-Progress Summary.................................................................................22
Interpretation of Results ...................................................................................23
Chemical Indicator Result..........................................................................23
Negative Test Result ...................................................................................24
Positive Test Result.....................................................................................24
Positive Result on a Positive Control .........................................................26

iv STERRAD VELOCITY Reader User’s Guide
First Negative Result on a Positive Control...............................................26
Second Negative Result on a Positive Control..........................................27
Optional Visual Interpretation of Results..................................................28
Chapter 5. Files ......................................................................................... 31
System Information Files ..................................................................................31
History Files........................................................................................................32
Notes...................................................................................................................32
Reader Log..........................................................................................................33
Chapter 6. Maintenance ..........................................................................35
Care and Cleaning ..............................................................................................35
Biological Indicator Disposal.............................................................................35
Reader Disposal .................................................................................................36
Chapter 7. Access Levels and Administrator Tasks .............................. 37
Access Levels .....................................................................................................37
Utilities Menu .....................................................................................................38
Admin Login ........................................................................................................38
Manage Administrators.....................................................................................39
Add New Account........................................................................................39
Edit or Delete Existing Account..................................................................39
Manage Sterilizers .............................................................................................39
Add New Sterilizer.......................................................................................40
Edit or Delete Existing Sterilizer ................................................................40
History.................................................................................................................40
View Details .................................................................................................40
Add Note ......................................................................................................40
System Conguration ........................................................................................41
Language Selection ....................................................................................41
Backlight Conservation ..............................................................................41
Volume .........................................................................................................41
Display Brightness......................................................................................42
Alert Sounds ................................................................................................42
Barcode Scanner in Use .............................................................................42
Reader Settings...........................................................................................42
Printer Settings ...........................................................................................42
Date and Time..............................................................................................43
Calibrate Insertion Sensor .........................................................................43
Network Settings ...............................................................................................43
ASP ACCESS Conguration ...............................................................................44

STERRAD VELOCITY Reader User’s Guide v
Control Alerts......................................................................................................44
File Management ...............................................................................................45
Update Software ................................................................................................45
System Information ...........................................................................................45
Reader Log..........................................................................................................45
Chapter 8. Troubleshooting .................................................................... 47
User Error Messages .........................................................................................47
System Error Messages.....................................................................................58
Call Your ASP Representative............................................................................58
Appendix A. Accessories and AdditionalParts ....................................59
Appendix B. Reader Specifications ........................................................ 61
Appendix C. User’s Network Connection Information.......................63
Appendix D. Compliance and RegulatoryStandards ..........................65
Appendix E. First Time Setup................................................................. 67
Network Setup....................................................................................................67
ASP ACCESS Setup ............................................................................................68
Date and Time Setup..........................................................................................69
Administrator Setup ..........................................................................................70
STERRAD Sterilizer Setup .................................................................................71
Reader Setup......................................................................................................71
Control Chemical Indicator Color Change Conguration Setup.....................72
Printer Setup ......................................................................................................72
Setup Complete..................................................................................................72
Appendix F. Software License Agreement............................................ 73

vi STERRAD VELOCITY Reader User’s Guide
THIS PAGE INTENTIONALLY LEFT BLANK

Introduction 1
STERRAD VELOCITY Reader User’s Guide 1
Chapter 1.
Introduction
This Guide will instruct the user in the proper care and operation of the
STERRAD VELOCITY™ Reader (reader).The reader provides a fast and reliable
way of testing the STERRAD VELOCITY™ Biological Indicator / Process Challenge
Device (biological indicator or BI). The BI is designed to test the effectiveness of the
STERRAD™ 100NX with and without ALLClear™ Technology, STERRAD NX™ with and
without ALLClear Technology, and STERRAD™ 100S Sterilization Systems. Failure
to follow the instructions provided in this guide may result in inaccurate results or
impairment of the safety features of the reader.
How to Use This Guide
If you are a reader operator, you must read the “Introduction” (Chapter 1),
“Safety Information” (Chapter 2),“Operation” (Chapter 4), and “Maintenance” (Chapter 6)
chapters prior to operating the reader. This “Introduction” explains the features and
parts of the reader. “Safety Information” explains personal safety as well as device
safety information.“Operation” explains how to operate the reader and obtain optimal
results.“Maintenance” explains how to clean and care for the reader.
If you are an administrator overseeing the reader, you should read the entire
User’s Guide and pay particular attention to the chapter featuring “Access Levels and
Administrator Tasks” (Chapter 7). This chapter describes tasks and options that are only
available through “Administrator-level” access.
Intended Use
The STERRAD VELOCITY Reader is used to incubate and automatically read the
STERRAD VELOCITY Biological Indicator / Process Challenge Device at 57°C (134.6°F)
for a nal uorescent result within 15 minutes. The BI is a rapid biological indicator
designed for frequent monitoring and periodic testing of STERRAD™ Sterilization Cycles
which use hydrogen peroxide as the sterilant. The BI used in conjunction with the reader
provides a fast and reliable way to verify the effectiveness of the STERRAD Sterilization
Cycle. The STERRAD VELOCITY Biological Indicator / Process Challenge Device is for use
in STERRAD™ Sterilizers only.

1Introduction
2 STERRAD VELOCITY Reader User’s Guide
Indications for Use
The STERRAD VELOCITY Reader, in conjunction with the STERRAD VELOCITY
Biological Indicator / Process Challenge Device, is intended to be used as a standard
method for frequent monitoring and periodic testing of the following STERRAD™
Sterilization Systems:
•STERRAD 100NX (STANDARD, FLEX, EXPRESS, and DUO Cycles) with
and without ALLClear Technology
•STERRAD NX (STANDARD and ADVANCED Cycles) with and without
ALLClear Technology
•STERRAD 100S
Product Description
The reader is an integral part of a monitoring system which tests the BI for
the presence of an indicator organism. The reader incubates the BI at 57°C (134.6°F)
and provides nal uorescent results within 15 minutes. The presence or absence
of the viable indicator organism, indicated by uorescence, in the BI determines
the effectiveness of the sterilization cycle. The BI and reader system is used for
frequent monitoring and periodic testing of the STERRAD NX with and without
ALLClear Technology, STERRAD 100NX with and without ALLClear Technology, and
the STERRAD 100S Sterilization Systems in hospitals and healthcare facilities.
If You Have Questions
If you are located in the United States and have questions about the
STERRAD VELOCITY Reader, please call ASP Professional Services at 1-888-STERRAD
(1-888-783-7723). Internationally, call your local ASP Customer Support Representative.
You may also wish to visit our website at www.asp.com.

Safety Information 2
STERRAD VELOCITY Reader User’s Guide 3
Chapter 2.
SafetyInformation
Your safety is important to Advanced Sterilization Products, Inc. (ASP). The
following sections provide information on safely using the STERRAD VELOCITY Reader.
You must read and understand the safety information before operating the reader.
Always pay attention to the warnings, cautions, and notes throughout this User’s Guide.
This information is for your safety and to ensure that you receive the most benet from
the safe operation of your reader.
Symbols
Emits laser radiation. Avoid direct eye exposure.
Warning.
Caution.
Ethernet. Ethernet Connection Port.
Front Color: PMS 325 C, PMS 426 C, Solid 100% White Ink =
Front Graphic Size: 140.4 mm x 17.4 mm
Rear Color: PMS 426 (Black)
Rear Graphic Size: 62.54 mm x 12.6 mm
GTIN: 10705037048915
Date: December 14, 2016
Part Number: 113729-01
Product: STERRAD VELOCITY™ Reader
Product Description: Outer Casing Artwork
Product Code [REF]: 43220
Front Graphic
Back Graphic
USB. Universal serial bus connector port.
Electric shock hazard.
Electric shock hazard.
Ultraviolet (UV) light hazard. Avoid direct eye exposure.
Direct current.

2Safety Information
4 STERRAD VELOCITY Reader User’s Guide
Waste Electrical and Electronic Equipment (WEEE) and EU Battery
Directive. This device contains circuit boards and a rechargeable battery
which need to be disposed of properly.
Catalogue number. Indicates the manufacturer’s catalogue number so
that the medical device can be identied.
Serial number. Indicates the manufacturer’s serial number so that a
specic medical device can be identied.
RCM. Indicates compliance with applicable ACMA regulatory
requirements.
Manufacturer. Indicates the medical device manufacturer.
Date of Manufacture. Indicates the date when the medical device
was manufactured.
Hot Surfaces.
ASP, The Netherlands BV
BIC 1, 5657 BX, Eindhoven, The Netherlands
Authorized representative in the European Community. This symbol is
accompanied by the name and address of the authorized representative
in the European Community.
eifu.asp.com
Consult instructions for use. Indicates the need for the user to consult
the instructions for use.
Fragile, Handle with Care. Indicates a medical device that can be broken
or damaged if not handled carefully.
This Side Up. Indicates the orientation the package should remain in
during shipping and storage.
For indoor use only.
Keep away from sunlight. Indicates a medical device that needs
protection from light sources.
Tabla de contenidos
Otros manuales de Equipo de laboratorio de ASP
Manuales populares de Equipo de laboratorio de otras marcas

Agilent Technologies
Agilent Technologies 5800 ICP-OES Manual de usuario

Endress+Hauser
Endress+Hauser Cleanfit CPA875 Manual de usuario

NI
NI PXI-5422 Manual

Collomix
Collomix Aqix Manual de usuario

SPEX SamplePrep
SPEX SamplePrep 6875 Freezer/Mill Series Manual de usuario

Ocean Insight
Ocean Insight FLAME-NIR+ Manual de usuario