ASD Smart Ethernet Adapter Manual de usuario

ASD Smart Ethernet Adapter Setup
Guide
ASD.Document 600240 Rev. D
© 2009 by ASD Inc.

ASD.Document 600240 Rev. D ii ASD Smart Ethernet Adapter Setup Guide
www.asdi.com

ASD.Document 600240 Rev. D iii ASD Smart Ethernet Adapter Setup Guide
www.asdi.com
Trademark Information
ASD Inc.
2555 55th Street Suite 100
Boulder, CO 80301 USA
Phone: (303) 444-6522
www.asdi.com
FieldSpec®, LabSpec®, QualitySpec®, QualitySpec ip ® BT, RxSpec®,
ViewSpec™, Indico™, AgriSpec®, RS3™, and TerraSpec® are registered
and unregistered trademarks, and the intellectual property of ASD Inc. (ASD),
Boulder, Colorado, USA. All trademarks used or displayed in this document
are trademarks of ASD, its affiliates, or third party owners. Unauthorized use
of these trademarks is illegal and punishable by law. Nothing contained in this
document is to be construed as granting, by implication, estoppel, or
otherwise, any license or right of use of any such trademark without the prior
and express written permission of ASD, or such third party owner.
This document contains proprietary information protected by copyright law
and may not be reproduced in any manner without the express written
approval of ASD Inc.
The information and specifications contained in this manual are subject to
change without notice. ASD Inc. shall not be held liable for technical,
editorial omissions, or errors made herein; nor for incidental or consequential
damages resulting from furnishing, performance, or use of this material.
Technical Support
If you have any questions or concerns, please contact ASD Inc. by phone, fax,
or email:
Phone: 303-444-6522 X-144
Fax: 303-444-6825
Web: www.asdi.com
ftp: ftp.asdi.com
Technical support is committed to providing you with a timely response to
your questions. We will work with you to provide solutions to your
applications. Technical support is available to answer your questions Monday
thru Friday, 8 am to 5 pm Mountain Standard Time. We will happily respond
to your e-mail queries as well.

ASD.Document 600240 Rev. D iv ASD Smart Ethernet Adapter Setup Guide
www.asdi.com

© 2009 ASD Inc. 1 ASD Smart Ethernet Adapter Setup Guide
Table of Contents
Trademark Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii
Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Computer Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Chapter 2 Software Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Upgrading the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Chapter 3 Network Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
TCP/IP Background . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Network Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Determine the Network Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Isolated Network (Default) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Established Network. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Chapter 4 Configuring Static IP Addresses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Configuring Windows XP with a Static IP Address. . . . . . . . . . . . . . . . . . . . 10
Configuring the ASD Smart Ethernet Adapter with a Static IP Address. . . . 14
Chapter 5 Configuring Dynamic IP Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Configuring Windows XP with a DHCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Configuring the ASD Smart Ethernet Adapter with DHCP . . . . . . . . . . . . . . 21
Chapter 6 Connecting the Hardware Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Verifying the Hardware Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
ASD Smart Ethernet Adapter Connections . . . . . . . . . . . . . . . . . . . . . . 25
Power ON Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Software Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
RS3Application Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Indico Pro Application Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Port Overview and Securing the ASD Smart Ethernet Adapter . . . . . . . . . . 33
Accessory Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Serial Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Secure ASD Smart Ethernet Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . 34

ASD.Document 600240 Rev. D 2 ASD Smart Ethernet Adapter Setup Guide
www.asdi.com
Chapter 7 Updating the Firmware in the ASD Smart Ethernet Adapter . . . . . . . . . . . . 35
Chapter 8 Troubleshooting Ethernet Communication . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Common Communication Fixes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Does Not Connect to the ASD Smart Ethernet Adapter. . . . . . . . . . . . . . . . 45
Verify the Fiber Optic Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

© 2009 ASD Inc. 1 ASD Smart Ethernet Adapter Setup Guide
Chapter 1 Introduction
These setup instructions apply to the FieldSpec™Pro and LabSpec™Pro
spectroradiometers.
The purpose is:
• to upgrade the ASD application software; and
• to configure the Smart Ethernet Adapter between the instrument
controller and the ASD spectroradiometer.
1.1 Computer Requirements
The instrument controller is a computer that manages the instrument
controller software, stores data, and processes the results.
The minimum requirements for the instrument controller are:
•1.2GHz Pentium or better notebook or PC-w/monitor
•256MB RAM or more
•20GB of free disk space
• 1024 x 768 or better graphics resolution
• 24-bit color or better - 32-bit recommended
•Ethernet port: 10/100 Base T Ethernet interface
•(Optional) Ethernet wireless (WiFi) adaptor: PCMIA, USB, or built-in
that is compatible with the 802.11b standard
•(Optional) Serial communications port (or USB port) for GPS receiver.
Only needed if you want to use GPS.
• (Optional) NMEA compatible GPS receiver
The instrument controller requires the following software:
•Either RS3Software or Indico Software from ASD.
•Microsoft Windows® 95/98/NT/2000/ME/XP Operating System.
• Microsoft Internet Explorer 6.0 or better.

ASD.Document 600240 Rev. D 2 ASD Smart Ethernet Adapter Setup Guide
www.asdi.com Chapter 1 Introduction
Users need a basic understanding of the Microsoft Windows operating system
including software installation.
International customers using non-English versions of Windows must alter
the Regional Settings under Start->Settings->Control Panel. The
default language must be set to English (United States) in order for the
software to be registered and operate correctly. The numbering format must
also be set to English.

© 2009 ASD Inc. 3 ASD Smart Ethernet Adapter Setup Guide
Chapter 2 Software Installation
The ASD software is usually installed on the (optional) instrument controller
(computer) prior to delivery. If an instrument controller was not purchased
with the Smart Ethernet Adapter, proceed with upgrading the software. The
software for RS3 must be version 4.0.24 or higher and Indico Pro must be
version 5.0.10 or higher.
2.1 Upgrading the Software
To upgrade the ASD application software, follow these steps:
Step 1 Insert the flash memory stick that was supplied with the ASD RS3 or Indico
Pro software into the USB port of a computer that has Internet access. This
may not be the same computer as the instrument controller.
Step 2 Open Windows Explorer and navigate to the “Removable Disk” icon and
open.
Step 3 Double click on “ASDInstall.exe” and open the ASD Product Installation
window.
Step 4 Select the software application to upgrade and follow the instructions.
Note: Select “Ethernet” for the Instrument Interface.

ASD.Document 600240 Rev. D 4 ASD Smart Ethernet Adapter Setup Guide
www.asdi.com Chapter 2 Software Installation
Step 5 Copy or move your data files stored from the previous versions of the
instrument controller software.
•ForRS3
The folder location for RS3 prior to version 4.0 is c:\Program Files\RS3.
The new installation folder for RS3 is c:\Program Files\ASD\RS3.
• For Indico Pro
The folder location for Indico Pro prior to version 4.0 is c:\Program
Files\IndicoPro. The new installation folder for Indico Pro is c:\Program
Files\ASD\IndicoPro.