<<Nozzle Safety Precautions>>
●Don’t put your hand or fingers or anything over the spray nozzle.
●Be extra careful when cleaning or replacing the nozzle.
If the nozzle gets clogged while spraying, immediately lock the trigger safety lock and relieve the
fluid pressure in accordance with the “Pressure Relief Procedure,” and then take off the nozzle
for cleaning.
It is dangerous to wipe sticky paint off the nozzle with some residual pressure still remaining or
without locking the trigger safety lock.
When relieving pressure, follow the procedure below:
<<Pressure Relief Procedure>>
To reduce the risks of injury from injection, splashing fluid on the skin or in the eyes, etc.,
relieve the pressure following this “Pressure Relief Procedure” whenever you:
Inspect the pump or gun, Remove or mount the nozzle for cleaning or replacement, Stop
spraying. The step-by-step procedure:
①Lock the trigger.
②Shut off air supply by turning the pressure control dial counter-clockwise, bringing down
the pressure all the way.
③Relive the ball cock, bring down the system pressure to zero, unlock the trigger and pull it
for double-checking.
④Lock the trigger again.
●When the nozzle or hose is clogged or when it is suspected that some pressure still
remains after going through the “Pressure Relief Procedure,” slowly loosen the chip
guard mounting nut or the connector at hose end, gradually releasing the pressure until it
is completely relieved. Then inspect the nozzle and hose.
Equipment Misuse Hazard
<<General Safety Precautions>>
●Misuse, such as use of too much pressure, unauthorized component modification, improper
paints or solvents, use of worn or broken part, may result in a serious accident like pump
breakage, unexpected fluid injection, fluid splashed in the eyes or on the skin that possibly
causes personal injury, or even fire or explosion.
●Don’t alter or modify pump parts without our authorization or approval, for such a change may
result in equipment failure or malfunction.
●Inspect the whole system periodically. Repair or replace parts as required.
●When conducting spray operation, always wear eye protection, protective clothing, and breathing
protection recommended by the paint/solvent manufacturer.
Depending on the kind of pint fluid used and the ventilation performance, an additional personal
protective equipment may be required. Please check it out with the paint/solvent manufacturer.
<<Equipment Interior Pressure>>
●Confirm the maximum fluid working pressure and maximum air input pressure of the pump.
Be careful not to exceed these maximum pressures when operating the pump.
Also, make sure that all component parts used for the equipment, such as hoses, connectors,
swivels, are compatible with the maximum pressures.
Should you find them not, set the pump at a pressure that does not exceed the lowest maximum
operating pressure of all parts and accessories used with the equipment.
● Each time you use the equipment, retighten all the joints before use.
WARNING