Aquatronica SMS Module Manual de usuario

SMS
MODULE
Cod. ACQ240
Instruction Manual

2 - 19 ISACQ240C(ENG)-0 Rev. 311007-0
Via dell’Industria, 20 - 42025 Cavriago (RE) Italy Tel.: +39 0522 494403
Table of Contents
• Information..................................................................................... Page 3
• Information on safety...................................................................... Page 4
•General instructions........................................................................ Page 5
•Package Contents............................................................................ Page 6
•SMS module overview ..................................................................... Page 7
•SMS module connection diagram..................................................... Page 8
•SMS module LED and button operation............................................ Page 9
•Icons glossary................................................................................. Page 10
•Main Menu....................................................................................... Page 11
Enabled/Disabled............................................................................................Page 11
Settings.........................................................................................................Page 11
Alarms..................................................................................................Page 12
Enter SIM PIN .......................................................................................Page 12
Recipients.............................................................................................Page 13
Message Centre.....................................................................................Page 13
SIM number..........................................................................................Page 13
PUK number..........................................................................................Page 13
Battery..........................................................................................................Page 13
Read SMS......................................................................................................Page 14
Black-Outs.....................................................................................................Page 15
About............................................................................................................Page 15
•Overview of error messages............................................................ Page 16
•Certicate of Warranty .................................................................... Page 17
•Declaration of Conformity................................................................ Page 18
•Technical Data................................................................................. Page 19
CHECK FOR ANY UPDATES ON THIS MANUAL ON THE WEBSITE

3 - 19
IsACQ240C(ENG)-0 Rev. 301007-0
Via dell’Industria, 20 - 42025 Cavriago (RE) Italy Tel.: +39 0522 494403
It is forbidden to reproduce, transfer, distribute or store in any form any part of this
manual without AQUATRONICA’s written authorization.
The information in this manual could be changed at any time without notice at AQUAT-
RONICA’s discretion.
Any such changes will be made in subsequent editions of this manual.
Please read this manual carefully before using the “SMS Module” system.
DISPOSAL OF ELECTRIC AND ELECTRONIC PARTS
Pursuant to Article 13 of Legislative Decree No. 151 of 25 July 2005, “Implementation
of Directives 2002/95/CE, 2002/96/CE and 2003/108/CE, regarding the re-
duction in use of dangerous substances in electrical and electronic equipment,
as well as waste disposal”
Products bearing the barred dustbin symbol must be disposed of separately from
other waste. The user must therefore dispose of the product in question at suitable
recycling centers for electronic and electro-technical waste, or he/she must turn over
the used product to the retailer when buying a new equivalent product, on a one-to-
one basis.
Separate waste collection allows used equipment to be recycled, treated and disposed
of without negative consequences for the environment and health, and it allows the
materials in the equipment to be recycled.
Illegal dumping of the product by the user entails the administrative sanctions
stated in Legislative Decree No. 22/1997 (Article 50 et seq of Legislative Decree No.
22/1997).

4 - 19 ISACQ240C(ENG)-0 Rev. 311007-0
Via dell’Industria, 20 - 42025 Cavriago (RE) Italy Tel.: +39 0522 494403
Information on safety
Use the SMS module only for the purpose for which it was designed; any other
use not provided for in this manual can cause irreparable damage to the control
unit.
Do not attempt to disassemble the SMS module, as it contains no parts that can
be repaired by the user.
Repairs must only be done at authorized centers by qualied personnel. The
company is not liable for any damage to things or harm to people if the control
unit is tampered with.
The SMS module comes with a non-rechargeable 9-volt battery.
When it is time to replace it (every 18 months, even if not signalled by the control-
ler), make sure a battery of the same family is used. Using non-approved batteries
may cause damage, even irreparable, to the control unit.
Only original AQUATRONICA parts, or those it approves, should be connected to
the control unit. The use of accessories that have not been approved can lead to
damage, re, electric shock and injury to people.
Position the control unit out of the reach of children to prevent the risk of electric
shock. The warranty does not cover failures due to the use of unapproved mate-
rial.
The control unit is not waterproof, so do not expose it to direct contact with
liquids. It is unadvisable to assemble it in particularly damp environments.
Do not use ammable liquids to clean it, which could come into contact with the
electrical parts and cause a re.
Avoid positioning the SMS module inside metal containers or in any case near me-
tallic masses. Non-compliance with this rule may cause system malfunctionings.

ISACQ240C(ENG)-0 Rev.301007-0 5 - 19
Via dell’Industria, 20 - 42025 Cavriago (RE) Italy Tel.: +39 0522 494403
General instructions
The Aquatronica SMS module is subject to interferences that can affect equipment
performance.
Do not enable the SMS module inside hospitals.
Abide by current provisions or rules with regard to possible interferences with
electric medical equipment.
Do not transport the Aquatronic SMS Module by air with the batteries inside.
Do not install the equipment near explosive materials.
Observe restrictions and abide by any envisaged provision or rule.
Most modern electronic equipment is shielded from radiofrequency signals (RF). Neverthe-
less, some electronic equipment may not be shielded from radiofrequency signals emitted
by the GSM Module.
PACEMAKERS
Pacemaker manufacturers recommend compliance with given precautions in order to prevent
possible interferences with the pacemaker:
- Keep the GSM Module (if enabled) at more than 20 cm from the Pacemaker.
- If for any reason you suspect there is an interference, immediately disable the equip-
ment.
HEARING AIDS
The GSM Modules may interfere with some hearing aids.
PLACES WHERE USE IS FORBIDDEN
Do not install the SMS Module anywhere you nd signs prohibiting the use of mobile pho-
nes.

6 - 19 ISACQ240C(ENG)-0 Rev. 311007-0
Via dell’Industria, 20 - 42025 Cavriago (RE) Italy Tel.: +39 0522 494403
You will nd:
1) 1 SMS module
2) 1 100/240 12-Volt feeder complete with 4 universal adapters
3) 1 BUS cable
4) 1 Quick-start
Package contents
2
3
1
4

ISACQ240C(ENG)-0 Rev.301007-0 7 - 19
Via dell’Industria, 20 - 42025 Cavriago (RE) Italy Tel.: +39 0522 494403
SIM CARD
9V battery
Battery coupling
connector
Green LED Red LED
P button
SIM Card
compartment
BUS outlet for
connecting the
Aquarium Controller
Power supply
connector
(12VDC)
Battery
compartment
SMS module overview

ISACQ240C(ENG)-0 Rev.301007-0 8 - 19
Via dell’Industria, 20 - 42025 Cavriago (RE) Italy Tel.: +39 0522 494403
Follow these instructions to correctly connect
the SMS module:
1) Put a 9 volt non-rechargeable battery
(not included in the package) inside its
compartment.
Note: Using the battery becomes necessary
only for managing the module if there is a
drop in voltage, whereas the module relies
on the mains voltage for managing all the
other functions.
2) Put the SIM in its compartment.
ATTENTION: The module must always be
turned off when the SIM is inserted; if
it is removed and the SIM is afterwards
put back in, it is necessary to reset the
module so as to once again go through the
initialisation procedure.
3) Connect the BUS cable to one of the sockets
on the power unit (as illustrated at the side).
Note: Do not by any means connect other
devices to the USB socket on the SMS
module. Not following this rule could
in fact cause irreparable damage to the
control unit.
4) Connect the mains power supply to one of
the sockets on the power unit (as illustrated at
the side) or to any electric mains socket.
NOTE: If the power supply unit is con-
nected to one of the power unit sockets,
it is necessary to set a timer program that
keeps this socket active 24 hours a day.
5) Wait for the module to complete the initiali-
sation procedure, during which the module will
be unable to operate.
Sms module connection diagram
BUS Cable
12V power supply unit
SIM compartment
Power Unit
Battery
compartment

9 - 19 ISACQ240C(ENG)-0 Rev. 311007-0
Via dell’Industria, 20 - 42025 Cavriago (RE) Italy Tel.: +39 0522 494403
SMS module LED and button operation
LED visual indicators
There are 2 LEDs on the SMS module:
1 GREEN LED (F1) regarding the status of the mod-
ule’s connection to the Aquarium Controller.
1 RED LED (F2) regarding the status of the GSM
transmitter.
Depending on the status detected, they may be blink-
ing or steady.
GREEN LED
Steady: The SMS module is working correctly.
Slow Blinking: There is an SMS module-Aquarium
Controller connection error.
RED LED
Steady: The module is working correctly.
Slow Blinking: The module is initializing itself and
connecting to the GSM network.
Fast Blinking: There are problems on the GSM network
(in this case the relative error code will be displayed on
the controller) or there has been a black-out (in this
case the module signals the black-out a few seconds
before switching itself off).
Functions assigned to the button P
You can directly enable/disable the module without entering the dedicated enabling/disa-
bling menu by pressing the button marked by the letter “P” just once. Every time the
button is pressed the module status will change, and is recognisable by the turning on
and off of the LEDs.
The module will be reset by keeping the button marked by the letter “P” pressed for at
least one second. This function may prove to be particularly advisable if you want to
learn the charge status of a battery inside the module (see the section dedicated to the
“Battery charge” menu).
•
•

ISACQ240C(ENG)-0 Rev.301007-0 10 - 19
Via dell’Industria, 20 - 42025 Cavriago (RE) Italy Tel.: +39 0522 494403
Icons glossary
Icons shown on the Aquarium Controller display
Icon Description
Informs the user that there is a new message to be read.
Indicates SMS Module low battery level.
Indicates the signal level the SMS Module is receiving
Indicates the SMS Module is disabled or the Bus cable is
disconnected
Tabla de contenidos