The Smart Natural Gas Detector is a home-use combustible gas
detector that warns leakage of natural gas.
In case the concentration of natural gas (methane as its main
component) is detected to reach the alarm setting value, the detector
will immediately release a sound and light alarm signal and send a
notice to the mobile phone app via the hub. You shall be on the alert
and take immediate and effective measures to troubleshoot the
danger, avoiding serious explosion accidents.
*An Aqara Zigbee 3.0 hub is required.
*To work with Apple HomeKit,a compatible Aqara hub is required.Please see
www.aqara.com/support for moreinformation.
Silence/Self-Test Button
Reset: Press quickly for three
times
Silence: Press once (in case of
alarm)
Self-Test: Press and hold for
over 3 seconds
Communication Distance
Test: Press once
Indicator
(Red/Yellow/Green)
Buzzer Sound Output
Silence/Self-Test Button
Product Introduction
English

Quick Setup
Add Device
1. Before activating the accessory, please make sure you have the
Aqara Home app downloaded and an Aqara Zigbee 3.0 hub installed.
2.Connect the device to power through the adapter.
Aer connecting to the power supply, the device will warm up for 3
minutes, please wait for 3 minutes, and the next step will be
performed aer the green indicator light is always on.
3. Please open the app, tap “Home” and then tap “+” in the top right
corner to enter the “Add Device (Accessory)” page. Select “Smart
Natural Gas Detector” and add it according to instructions in the
Aqara Home app.
4. Please seewww.aqara.com/supportfor additional information.
What's In The Box
Adapter × 1 Self-Tapping
Screw × 2
Adhesive
Sticker × 1
Mounting
Plate × 1
Expansion
Tube × 2

Installation and Usage
Please confirm that communication between the Smart Natural Gas
Detector and the Aqara Zigbee 3.0 hub works normally, and then install
and fix it in position.
1.The detector should be installed indoors and located in the same
room with the stove or gas source.
2. The detector should be installed within a horizontal distance of more
than 1 meter and less than 4 meters from the stove, and the height
should be more than 0.5 meters above the stove for wall mount
installation, with the distance from the ceiling less than0.3 meters.
3. The detector should not be installed directly above the stove or on
any position that can be directly affected by the exhaust, steam and
cooking fume from the stove.
4. The detector should not be installed near the fans, air conditioners,
fresh air entrances and exits where the wind speed is too fast.
*If adding fails, please move the product closer to thehub and try again.
*For the description of the preheat function, please see the description of the preheat
function.
Installation Instructions

Ceiling mount position:
5. The detector should not be installed in places with massive moisture
or large amount of water vapor, such as bathrooms.
6. The detector should not be installed in places with temperature
below -10°C or above 55°C.
Gas stove

Installation
Please first place the detector in the target position for installation,
connect the power cord, and press the silence/self-test button to verify
the communication distance. You should make sure that the device
communicates properly with the hub before installing and fixing it in
position.
Wall mount position:
<0.3 meters
Gas stove

Installation with screws
1.Choose a suitable position and use an impact drill to punch holes in
accordance with the holes on the mounting plate.
2. Install the expansion tube at the punch position.
3. Secure the mounting plate with self-tapping screws.
4. Align the "△" mark on the back of the detector with the same mark
on the mounting plate, and rotate clockwise to fix it.
5. Use screws first to ensure a more secure installation.
Installation with adhesive
1.Remove the protective film on one side of the adhesive sticker, and
stick the adhesive sticker on the back of the mounting plate.
2. Choose a proper position for installation and make sure its surface is
smooth, clean and dry.

Status signal of the detector
The detector is equipped with a wireless networking interface, which
can output the following status signals.
3. Please do not stick the mounting plate on the surface of the wall
paint and other coatings, otherwise the sticking position is prone to
peeling aer a period of time, resulting in falling off of the detector.
4. Remove the protective film on the other side of the adhesive sticker,
stick and secure the mounting plate evenly.
5. Make sure that the mounting plate is firmly stuck within 30 seconds
(it is recommended to leave it still for 24 hours before installing the
detector).
6. Align the "△" mark on the back of the detector with the same mark
on the mounting plate, and rotate clockwise to fix it.

Preheating Preheating
The red, yellow and green
colors flash in cycle aer
power on until completion
of preheating
Green light is always on
Three beeps
aer power on
No sound
Normal
monitoring
Status Indicator Buzzer App
Monitoring
normal
The red, yellow and green
colors flash in turn, with
duration of each flash one
second and a pause every
three flashes
One beep per
second, with a pause
every three beeps
Self-test Self-test
Red light flashes
once per second
One beep per
second, with a pause
every three beeps
Natural gas
leakage alarm
Natural gas
leakage
alarm
Red light flashes once
every 4 seconds
One beep per
second, with a pause
every three beeps
Linkage alarm Linkage
alarm
Yellow light is always on Beep every
5 seconds
Fault Fault
Yellow light flashes three
times every 5 seconds
Three beeps
every 5 seconds
Out of
service life
Out of
service life

Preheating
Once the detector is powered on, the buzzer beeps three times and the
indicator flashes red, yellow and green in cycle. Aer 3 minutes, the
preheating ends and the indicator keeps in green, which indicates that
it is detecting normally.
Self-test
1.In the normal working status of the detector, the indicator is always
green. Hold down the silence/self-test button for more than 3
seconds to confirm that the indicator flashes red, yellow and green in
turn, with three beeps of the buzzer, which indicates that the
self-test is normal.
2.Press and hold the button until the indicator and buzzer repeat the
Tips: In case of use for the first time or non-use for a long time, the
detector should be charged continuously for more than 72 hours for
the optimal detection capacity.
The wireless networking interface of the detector can output a signal
corresponding to its measured concentration and display the
corresponding value in the app as a percentage of the lower explosive
limit (LEL).
Tabla de contenidos
Idiomas:
Otros manuales de Detector de gas de Aqara
Manuales populares de Detector de gas de otras marcas

Macurco
Macurco GD-6 Manual de usuario

Evikon
Evikon E2632 Manual de usuario

Critical Environment Technologies
Critical Environment Technologies CGAS-A Series Manual de usuario

MSA
MSA altair 5 Manual de usuario

DOD Technologies
DOD Technologies ChemLogic CL96 Manual de usuario

DEGA
DEGA NS III LCD Series Manual de usuario