Owner’s Manual
• Electro-Chemical Carbon Monoxide Gas Sensing
• Designed to Last Up to 10 Years
• Rate of Rise Temperature Sensing
• Fixed Temperature Sensing
• Proprietary Wireless Connectivity
• Compatible with the Comm Link and
OmniShield App
10 Year
Carbon Monoxide Sensor
Assembled in the USA

2
General Information About Your Carbon Monoxide Sensor ........................ page 3
Contents of Your Kit ................................................................................... page 4
General Warnings About Carbon Monoxide Gas ..........................................page 5
Understanding the Dangers of CO Gas Poisoning.........................................page 6
Recommended Locations for Your CO Sensor ............................................. page 7
Areas Not Appropriate for CO Sensors ....................................................... page 8
Complete Home Fire Protection .................................................................. page 9
Acceptable Wireless Network Sensor Spacing ............................................. page 9
Sensor Features and Functions ............................................................ page 10-11
Deactivating Your CFCO10 Sensor...............................................................page 12
Creating Your Wireless Network ............................................................... page 13
Adding a Sensor to Your Radio Network ................................................... page 14
Removing a CO Sensor from Your Radio Network ..................................... page 15
Choosing the Mounting Location in a Room ............................................ page 16
How to Mount the CFCO10 Sensor ........................................................... page 17
Sensor Specifications ................................................................................ page 18
Important Fire Safety Information ............................................................ page 19
Warning! Limitations on CO Sensors ........................................................ page 20
Limited Warranty ...................................................................................... page 21
Replacement Guarantees .......................................................................... page 22
Applied Fire Technologies recommends a combination of early-detecting
Smoke Sensors, CO Sensors and reliable Heat Sensors installed in their
appropriate locations throughout the home.
Smoke, CO and Heat Sensors are not a substitute for an adequate homeowner’s
fire/property insurance policy.
Table of Contents
ATTENTION - This manual should be read, followed and retained for future
reference.

3
What Makes the CFCO10 CO Sensor Different?
About Your New Carbon Monoxide Sensor
Thank you for purchasing the CFCO10 Carbon Monoxide Sensor. CO sensors
play an important role in protecting your family and home from the dangers of
carbon monoxide gas. Please carefully read and follow the information in this
booklet to ensure that your sensor operates properly and is located in the areas
best suited for activation.
Illuminated status icons
for Power, Warning,
Wireless, and Fire
Two modes of electronic
temperature sensing for a
very fast response
Dual functioning test
and silence button
The latest electro-
chemical CO sensor Attractive and durable
materials for a sturdy,
high-quality product
Sealed lithium battery
Frequency hopping
for superior wireless
communication

4
Contents of Your Kit
Please be sure the items below are included with your CO sensor:
CO Sensor
Instruction
Manual
Mounting Bracket
Key Features
• The latest electro-chemical CO sensing technology.
• Electronic temperature sensing with Rate of Rise and Fixed Temperature triggers.
• Fast response to CO gas exposure.
• Wireless communication to connect all products into their own unique home
network.
• Powered by a sealed, long-life lithium manganese battery.
• Four illuminated icons to easily demonstrate the CO sensor’s status.
• Multi-function button to allow for testing and silencing of unwanted triggering.
• Uniquely loud horn to notify occupants of CO gas and fire danger.
• Compatible with the Comm Link and OmniShield App.
1” Screws (2)
Self Adhesive
Labels (2)

5
Activation of your CO alarm indicates the presence
of carbon monoxide gas (CO) which can KILL YOU.
General Warnings About Carbon Monoxide Gas
WARNING
If your CO alarm signal sounds with the 4-beep pattern:
This carbon monoxide alarm is designed to detect carbon monoxide gas
from ANY source of combustion. It is NOT designed to detect smoke, or any
other gas types. The alarm also is equipped with Supplemental Temperature
Sensing. This will activate the alarm if the temperature reaches either 135°F
or the temperature rises by more than 20°F in a minute or less.
The CO alarm becomes susceptible to nuisance alarms when subject to
prolonged exposure to certain cleaning supplies, hairsprays and perfume
products. Care should be taken to install the CO alarm in spaces that are
well ventilated where these types of items are stored or used.
1. Press and release the Silence Button.
2. Call your emergency services ( ) ____ - ______, fire department
or 911.
3. Immediately move to fresh air - outdoors or by an open door or
window.
Do a head count to check that all persons are accounted for.
Do not re-enter the premises nor move away from the open
door/window until the emergency services responders have
arrived, the premises have been aired out, and your alarm
remains in its normal condition.
4. After following steps 1-3, if your alarm reactivates within a 24
hour period, repeat steps 1-3 and call a qualified appliance
technician ( ) ____ - ______ to investigate for sources of CO
from fuel burning equipment and appliances, and inspect
for proper operation of this equipment. If problems are
identified during this inspection, have the equipment serviced
immediately. Note any combustion equipment not inspected
by the technician and consult the manufacturers’ instructions,
or contact the manufacturers directly for more information
about CO safety and this equipment. Make sure that motor
vehicles are not, and have not been, operating in an attached
garage or adjacent to the residence.
•
•

6
3. Extreme Exposure: Unconsciousness, convulsions, cardiorespiratory failure,
death.
The following symptoms are related to Carbon Monoxide Poisoning and need to
be discussed with ALL members of the household:
1. Mild Exposure: Slight headache, nausea, vomiting, fatigue (often described
as “flu-like” symptoms).
Understanding the Dangers of CO Gas Poisoning
Many cases of reported CARBON MONOXIDE POISONING indicate that while
victims are aware they are not well, they become so disoriented they are unable
to save themselves by either exiting the building or calling for assistance. Young
children and household pets are typically the first affected.
2. Medium Exposure: Severe throbbing headache, drowsiness, confusion, fast
heart rate.
Potential Problem Sources of CO Gas Inside the Home
The sources of Carbon Monoxide gas can be very difficult to locate due to the
odorless, colorless nature of the gas, especially after the home has been aired-out
prior to the investigators arrival. Look closely at the following:
1. Excessive spillage or reverse venting of fuel burning appliances:
• Outdoor conditions such as wind direction and/or velocity,
including high gusts of wind; heavy air in the vent pipes (cold/
humid air with extended periods between cycles).
• Negative pressure differential resulting from the use of exhaust
fans.
• Simultaneous operation of several fuel burning appliances
competing for limited internal air.
• Vent pipe connection vibrating loose from clothes dryers,
furnaces, or water heaters.
• Obstructions in, or unconventional vent pipe designs which
amplify the above situations.
2. Extended operation of unvented fuel burning devices (range/oven, fireplace).
3. Temperature inversions which can trap exhaust gases near the ground.
4. Car idling in an open or closed attached garage, or near a home.
5. Poorly designed or maintained chimneys and/or vents.

7
Note: Applicable building codes or other local laws
may require the installation of CO and fire sensors
in addition to the minimum recommended by this
manual.
Bedrooms. A major threat from poisonous
CO gas occurs at night when people are
sleeping. For added protection, CO sensors
can be installed in all sleeping rooms.
Living Spaces. To enhance safety, a CO
sensor can be located in the living spaces of a
home.
Recommended Locations for your CO Sensor
Recreation and Dining Rooms. For
additional protection, a CO sensor can be
located in the other living spaces of the
home.
Hallways. A CO sensor is required to be
centrally located outside of each sleeping
area, and on every level of the home.
If your hallway is longer than 40 feet, install a
CO sensor at both ends.
Basements. A CO sensor should be located
on every level of the house, including the
basement.

8
Areas Not Appropriate for CO Sensors
Kitchens. Do not install within 5 feet
(1.5m) of kitchen appliances. The by-
products of cooking food can affect the
performance of the CO sensor.
Garages. Do not install in garages.
Exhaust gases from idling vehicles in an
open or closed garage can trigger the CO
sensor.
Attics. Do not install in attics. A CO
sensor can be affected by dust, small
insects or high and low temperatures.
Do not install the unit in areas where
the normal ambient temperature can go
below 40°F (5°C) or exceed 100°F (38°C).
Utility and Furnace Rooms. Do not
install close to equipment that can create
steam and gas. Steam and exhaust gases
can affect performance of CO sensors. CO
sensors should be at least 20 feet (6m)
from sources of combustion.

9
S
H
CO
BS
H
H
H
S
SSS
S
CO
CO
CO
BS
BS
H
H
H
SS
SS
CO
CO
BS
BS
CL
CL CL
W
S
W
S
W
S
W
S
Complete Home Protection
Applied Fire Technologies recommends complete home fire/safety protection.
This can be best achieved by installing a combination of Smoke, CO, Heat
Sensors, BedShakers, Water Sensors and a Comm Link in the appropriate
locations throughout the home.
Single Story Homes
Attic
Kitchen Living Rm Bedroom Hall Bedroom
Crawl Space
Two Story Homes
Attic
Bedroom Bedroom
Hall
Living Rm
Kitchen
Utility Room
Basement
Recommended BedShakers
Recommended Heat Sensors
Required Interconnections
Minimum Required CO Sensors
Minimum Required Smoke Sensors
Recommended Comm Link
Recommended Water Sensors
Acceptable Radio Network Sensor Spacing
Each unit will also act as a repeating station,
so any signal received by a sensor will be
rebroadcast.
After final installation, test all sensors
for proper radio inter-connection.
Simply press and release the test
button of a sensor while having a
helper observe the remote sensors.
Maximum
Spacing in
Open Area
200’ (70m)
The proprietary network communicates using
radio frequencies between 905.2MHz and
913.2MHz.
The range of the radio has been tested to 200
feet (70m) in open area distance testing.

10
CO Sensor Features and Functions
Power Indicator Light (Green)
On the CFCO10, the POWER icon will briefly flash once
every 30 seconds when the unit has been activated.
WIRELESS will flash once per second to indicate the radio
network is open to accept additional sensors into the
network.
Wireless Networking Light (Blue)
Warning Light (Red)
WARNING will flash rapidly when a CO sensor detects
sufficient levels of CO gas. This will be accompanied
by the 4-beep sounding of the horn.
FIRE will flash when the alarm detects sufficient
quantities of heat. This is accompanied by the sounding
of the horn.
Fire Warning Light (Red)
The FIRE warning light can be triggered in two ways
on the CO sensor, either exposure to sufficient heat or
remotely by another sensor on the wireless network.
WIRELESS will cease to flash one minute after the last
sensor has been added to the network or immediately
after the front button has been pressed.
WARNING will flash red every 30 seconds
accompanied by the horn chirp, for a minimum of 7
days, to indicate Low Battery. Replace the unit.
FIRE will continue to flash twice per minute (without the
horn) for three days after exiting an alarm condition, or
until the front button has been pressed and released.
WARNING will double flash red every 30 seconds
accompanied by the horn chirp, to indicate that the
CO sensor has reached its End-of-Life. Replace the
unit.
FIRE will stay on continuously if the unit was triggered
remotely by another sensor on your radio network. A
remotely triggered sensor will exit alarm mode after 5
minutes, unless during that time it was able to directly
detect the fire.