AOR Trans.View AR570 Manual de usuario

Stand Alone Color Image Facsimile
System
MODEL:
Trans.View AR570
Operating Man al
AOR, LTD.

Table of Contents
1: Specifications 4
2: Introduction 2
2-1: General Description 2
2-2: Equipment List 3
2-3: Applications 4
3: Summary of ontrols 4
3-1: Front Panel 4
3-2: Rear Panel 6
3-3: DIP Switches 7
3-3-1: Mode Switch (MODE-SW) 8
3-3-1-1: Operating Mode 8
3-3-1-2: RS232 communication speed and Automatic Dialing Transmission 9
3-3-2: ontinuous Transmission and DTMF Remote ontrol Mode (AUTO-SW) 10
3-3-2-1: ontinuous Transmission (for only operation via leased line) 11
3-3-2-2: DTMF Remote ontrol 12
3-3-3: N U function (N U-SW) (for only operation via leased line) 13
3-3-4: Station ID and Superimpose 14
3-4: DTMF ommands 15
3-5: Daytime lock adjustment and program phone number 16
3-5-1: Adjust daytime clock 16
3-5-2: Program phone number 17
3-5-3: Sender’s name 18
3-6: Superimpose 19
4: Installation 20
4-1: General 20
4-2: apture Device 22
4-3: Display Device 22
4-4: Public Telephone Line onnection 22
4-5: Radio onnections 22
4-6: Power Source 24
5: Operation 25
5-1: Operational Tests and Adjustment 25
5-1-1: Telephone Equipment 25
5-1-1-1: Acquire image, image transmission and reception 25
5-1-2: Radio Equipment 27

2
6: Extended Operation 29
6-1: Remote ontrol 29
6-1-1: Remote ontrol over leased line link 29
6-1-2: Remote ontrol over two-way Radio link 34
6-2: Full Automatic picture transmission control (use for only leased line) 35
6-2-1: One Transmission 35

3
This equipment has been tested and found to comply with the limits for a lass B digital
device, pursuant to part 15 of the F Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may causes harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by tuning the equipment OFF and ON, the
user is encouraged to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
onnect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
onsult the dealer or an experienced radio/TV technician for help.
This manual is protected by copyright AOR, LTD. No information contained in this manual
may be copied or transferred by any means without the prior written consent of AOR,LTD.
opyright ©1998 All rights reserved.
Names of products used in this manual are for identification purpose only and may be
trademarks or registered trademarks of their respective company.

4
1: Specifications
Product AR570 Still Image Color Facsimile System.
Operating Mode AOR original SCFM format and protocol
Color 27, 9 second mode
Black & White 18, 35 second mode
Video Input/Output NTSC (or PAL) Asynchronous
4fs sampling/75Ω1v p-p
Still Image Input Signal 0dB +10/-30dB
Still Image Output Signal 0~150mVrms (variable)
Modulation VCO modulation by DSP
Demodulation Arctangent Angle demodulation by DSP
Color Decoding Digitally processed by DSP
COM. Port DB9 Male for expansion and Interface to PC
NCU Automatic dialing and reception
Ringing time for automatic reception
1 to 7 times (programmable)
Termination of linked line Automatic/
manual (detection of no sounds in 5, 30, 0 second)
DTMF Control Built in
Power Requirement DC12V (11.7 to 15.8VDC) at 300mA
maximum (DC12V)
Dimensions 150 x 120 x 50mm
Weight 8 0 grams
Accessories supplied Black/Red twin color DC cord
Telephone line cable with modular jack (both)
8P Metal microphone connector (disassembled)
DIN 5Pin Plug
Instruction manual(3.5-inch floppy diskette)

5
2: Introduction
2-1: General Description
AOR model AR570 is the latest addition to the AOR’s growing family of imaging communication
products.
The AR570 has been designed for the two-way video communications. It is capable of transmit
and receive full-color, television-quality still images, over standard analog radio, telephone and
cellular lines.
The AR570 is ideal for Business, Commercial and Professional users. For example; in advertising
agencies and manufacturing firms who need to transmit and receive high-quality, high-resolution
pictures, diagrams, engineering drawing, etc., without regard to time and distance constrains.
The AR570 is also ideal for the public safety, military, security and news/broadcast applications
where traditional video transmission for a distant point is impossible. Since the AR570 can easily
be adapted to an existing voice grade circuit, including land mobile radio, maritime radio, airborne
radio, long distance SSB radio and even through satellite link.
The AR570 is using advanced DSP technology to offer superior picture quality and extremely
simple operation. Intelligent design of the unit allows stand alone operation. NO PCs are absolutely
necessary. It’s DC operation and compact size allows even mobile operation.
Extra fine and standard resolutions are provided for both full color and Black & White operation.
Image frame memory, telephone line interface (a NCU function is also provided for automatic
dialing and reception over telephone line network), built-in microphone relay, computer interface,
DAT/MD compatible recorder jack, rugged metal case, DC operation are all standard feature of the
AR570.
A dedicated terminal software from options is also available for NTSC or PAL version
depends on the item your purchased. Please call your local distributor if it is necessary.

6
2-2: Equipment List
AR570
At least two AR570s are needed. One for originating station and the one for distant station. The
unit is designed to run at DC12V regulated power source so that you may need to hock-up car
battery for mobile use.
Media Equipment
In addition to the AR570 and power supply, the media is needed.
Typical media for the AR570 is a standard telephone line or radio equipment such as transceiver,
transmitter or receiver. The AR570 is not a media sensitive equipment thus Cellular phone can be
used.
For a one-way image distribution by radio wave, you may replace receiving side to a conventional
scanners or receivers.
Image apture Device
A Commercially-available image capturing device namely; camcorder, electronic camera, video
tape recorder, image scanner or VCR, etc. The device must have video output for connection. The
AR570 is also designed to accept a Black & White device, such as CCD camera, Infrared camera
or low light camera that has compatible output.
Image Display Device
A commercially-available image display device namely; TV, TV monitor, Video Printer or a
flat-panel LCD monitor, etc. The device must have video input.

7
2-3: Applications
As a result of extensive market research, AOR found that AR570 has application beyond
commercial use. Potential AR570 application include distant learning, presentation, remote
consultation, experts extension, design exchange, concept exchange, filed service
assessment-maintenance, remote surveillance, remote security and news gatherings.
In medical emergency application when the system is tied to existing telephone or cellular phone,
the AR570 could be used as a part of remote treatment by allowing doctors to see and discuss
special procedures and / or pharmaceutical updates, etc., as part of second option remote
consultations.
In filed engineering/construction/manufacturing, the AR570 would allow for the image transmission
from a remote site, or can be exchange of engineering drawing, blueprints, parts and components,
and prototype models.
For the security and military use, when the low right camera is connected, the still image from the
remote site can be obtained just like a picture taken by surveillance camera.

8
3: Summary of ontrols
3-1: Front Panel
POWER LED
This LED will illuminate in green color when the AR570 is ON.
POWER (Toggle switch)
The POWER switch toggles between ON and OFF. UP is ON and DOWN is OFF.

9
A Q (3.5mm dia monaural jack)
This jack is an external input terminal. This is the same function that you push the TX switch by
contacting two terminals. Once the two terminals are connected, the AR570 will immediately
acquire the live picture from the camera of which is connected to the VIDEO IN on the rear panel of
the AR570 and will image the picture onto the memory. After that, the AR570 will transmit the
image to a distant station over radio link or telephone line link under picture mode selected by DIP
switch on the bottom side of the AR570. The job sequences using the ACQ terminals on the
AR570 Telephone version are;
ontacted the terminals→
→→
→acquire live picture→
→→
→hang up telephone line→
→→
→make dialing to the
specified telephone number (Once the line is connected)→
→→
→transmit the image→
→→
→hang off the
line→
→→
→standby
Note: In the se uential
....................
functions above
..............
, the AR570 radio version is not activated to make
..................................... ....
the dialing.
...........
The ACQ LED will light while acquiring the picture and off when it is finished. After that, the AR570
will start to transmit the image promptly and the TX LED will also light simultaneously. Once
transmission of the image is over, the AR570 will turn to standby mode and the TX LED will off.
HOLD (Toggle switch)
The HOLD switch activate and deactivate over drown function by new image. If this switch is UP
position, the AR570 will not capture new image. Also, the AR570 will not activate image data
transmission via RS-232C port in case of UP position. The HOLD switch is in UP position, the RX
LED will not illuminate.
VOI E LED
This LED will illuminate in yellow color while no operating of the AR570 together with the radio
transceiver. No available to use voice operation using microphone when this LED is not
illuminated.
Tabla de contenidos