AMC LARIO Plus Manual de usuario

www.lariohub.com 1LARIO - User manual v1.0 EN
Index English
SYSTEM MANAGEMENT VIA APP
1. REGISTERING THE APP 2
2. PAIRING THE CONTROL PANEL 3
3. MANAGING THE SYSTEM 3
4. VIDEO VERIFICATION 5
5. OTHER FUNCTIONS 6
6. INSTALLER SPACE 6
GENERAL INFORMATION
1. IMPORTANT NOTES 7
2. PACK CONTENTS 7
3. INSTALLATION 7
4. CONFORMITY 7
5. STANDARDS 7
6. MANUFACTURER 8
7. FEATURES 8
8. WARRANTY 8

www.lariohub.com 2LARIO - User manual v1.0 EN
SYSTEM MANAGEMENT VIA APP
AMCPlus
AMCPlus+
VIDEO VERIFICATION
It is possible to view
the version of the App
through the appropriate
key.
1. REGISTERING THE APP
Enabling automatic login,
it will not be necessary
to enter your credentials
every time you log into
the App.
1.1 Download the App and proceed with registration
by tapping the appropriate “Sign Up” key.
1.2 Fill in all the required fields. Set a password
and press the “Sign Up” key.
1.3 A code will be
sent via e-mail.
1.4 Enter the code and
press the “Sign Up” key.
1.5 An e-mail
confirming registration
will be sent.
1.6 Now the App is registered and it is possible to log
in with the previously set credentials, entering them and
tapping the “Sign In” key.

www.lariohub.com 3LARIO - User manual v1.0 EN
1. Give your control panel a name
2. Detect the UID code via the QR code
(allow access to the camera)
3. Enter the username
4. Enter the password
2. PAIRING THE CONTROL PANEL
3. MANAGING THE SYSTEM
2.1 Click on the key “+”
to add the control panels.
2.2 Fill in all the
required fields: The required fields 2 - 3 - 4 in this
section must correspond to those
entered during the programming phase
by the installer.
They are found on page 6.
2.3 Once entered, save the
data using the appropriate
“Save” key.
2.4 The added control panel
will be visible at the top of
the screen.
It is possible to delete or
modify the characteristics of
the control panels inserted
by pressing and holding the
icons of the control panels
themselves.
The control panel icon will have
different types of colour depending
on the status:
GREY: everything ok
YELLOW: problem (low battery,
no power supply, etc.)
RED: alarm
3.1 To access the system management, click on the control panel
icon and then enter the personal code.

www.lariohub.com 4LARIO - User manual v1.0 EN
3.3 Use the
appropriate key to
arm the individual
Program.
3.2 Clicking on the arrow accesses the AREAS section where it is
possible to arm/disarm the PROGRAMS, to exclude/include the ZONES
and activate/deactivate the OUTPUTS.
The names of the AREAS,
PROGRAMS, ZONES, and OUTPUTS
can be changed by the installer via
the control panel using the technical
code. The App will automatically
receive the new terminology.
The PROGRAMS and
AREAS icons take
on different colours
depending on the status:
disarmed
armed
system
in alarm
open zone
or anomalies
3.4 Clicking on the arrow it is possible to access
the Zones and Outputs belonging to the relevant
Program.
By clicking on the
triangular icon it
is possible to view
the anomalies.
zone
in alarm
zone
not ready
zone
ready
zone
included
zone
excluded
output
deactivated
output
activated
The icons of the ZONES and OUTPUTS take on different colours depending on the status:

www.lariohub.com 5LARIO - User manual v1.0 EN
4. VIDEO VERIFICATION
The map can always be
viewed by rotating
the phone.
3.5 Clicking on the individual AREAS, PROGRAMS, ZONES,
OUTPUTS accesses a screen on which to assign an image (allow
access to the camera).
Clicking on the appropriate
button it is possible to view
the icons of the AREAS,
PROGRAMS, ZONES,
OUTPUTS on the map and
act directly from this screen.
video
zone
4.1 Clicking on the REC icon it is possible to
activate a video recording and subsequently
receive it on the App. When the video is
available, a PUSH will be sent (average receiving
time 1 minute).
4.2 From the NOTIFICATIONS
section, by clicking on any
video notification, it is possible
to access the list of available
videos.
4.3 By clicking on the
appropriate key it is
possible to download
the video in the photo
gallery of the phone.
Only with the Plus+ version of the App
it is possible to manage the video section.
The videos remain available on
the App for 48 hours only.

www.lariohub.com 6LARIO - User manual v1.0 EN
5. OTHER FUNCTIONS
NOTIFICATIONS menu
Through this menu it is possible to receive the following default
notifications: alarms and anomalies.
The installer, during the programming phase, can enable the
sending of other notifications:
- user accesses
- arming/disarming
- name of the user who armed/disarmed the system
SYSTEM STATUS menu
Through this menu it is possible to check the status of the control panel: battery level, power supply etc.
The red icon indicates an anomaly.
Control panel username .................................. Control panel password .....................................
Control panel UID
...................................................................................................................
UID QR
6. INSTALLER SPACE
By clicking on the “lock” icon, the installer is given the
opportunity to programming the control panel:
enabled installer access
disabled installer access

www.lariohub.com 7LARIO - User manual v1.0 EN
1. IMPORTANT NOTES
All the products mentioned in this manual comply with the rules relating to the EN 50131 standard.
IMQ certification - Grade 2 - Class 2 security systems
To ensure compliance with these standards, the control panels must be programmed as indicated in the specific
tables in the installation manual.
The cardboard box contains:
• ABS cabinet
• LARIO control panel electronic board
• LITHIUM buffer backup battery model 18650
• anti-opening and removal tamper kit (mandatory for EN standards)
• screws to assemble the parts and to close the cabinet
• adhesive label with product data
The cardboard box does not contain:
• fisher for wall fixing
• standard 12Vdc @ 1A power supply unit (we suggest the AMC model L-AL power supply)
• 2G - 4G module
The LARIO programming APP can be downloaded from the APPLE and GOOGLE
markets. The installation manual can be downloaded from www.lariohub.com
• The information contained in this manual is for informational purposes only and is the property of
AMC Elettronica.
• All the information contained in this manual is subject to change without notice.
• Each part of this manual must be interpreted and used only for the purposes for which it has
been drawn up. Any use other than that prescribed must be authorised by AMC Elettronica, otherwise
the warranty lapses.
• All trademarks, symbols and examples contained in this manual belong to their respective owners.
AMC Elettronica declares that the LARIO intrusion alarm control panels comply with the requirements and
provisions established by directive 1999/5/CE.
4. CONFORMITY
5. STANDARDS
2. PACK CONTENTS
GENERAL INFORMATION
• The installation must be performed to a professional standard by specialist personnel, respecting the
national plant engineering regulations.
3. INSTALLATION

www.lariohub.com 8LARIO - User manual v1.0 EN
AMC Elettronica guarantees a product free from manufacturing defects.
As the product is not installed by the manufacturer and can be used together with other products not made by
AMC Elettronica, the manufacturer does not guarantee and is not responsible for damage and/or theft or other
types of problems deriving from incorrect installation and/or system configuration.
The guarantee therefore does not cover:
• improper use of the equipment
• programming errors or negligence on the part of the installer
• manipulation and vandalism
• wear of the product
• lightning, floods, fire
AMC Elettronica reserves the right to repair or replace the defective product within the established limit of 24
months. Any use other than that indicated in this manual will invalidate the warranty.
The installation must be performed to a professional standard by specialist personnel.
8. WARRANTY
7. FEATURES
6. MANUFACTURER
AMC ELETTRONICA
Via Pascoli, 359 - Loc. Mirovano - 22040 Alzate Brianza (CO) Italy
• Power supply 12 Vdc
• Nominal consumption 100 mA
• Maximum consumption 400 mA
• Battery 18650 Lithium 3.7 Vdc 2Ah
• Wireless 868 full duplex in diversity of frequency
• Wi-Fi on board
• 4G optional module
• 3 areas
• 3 programs for each area
• 64 users
• 64 zones
• 32 generic devices (detectors, etc.)
• 20 remote control
• 4 wireless repeater
• 4 keypads
• 4 sirens
• 8 outputs expansions
• 100 programmable sceneries
• 6 indication LEDs:
- Power supply
- Battery
- Radio signal
- SIM
- Wi-Fi
- Cloud activity
• Grade 2, Class II

www.lariohub.com 9LARIO - Manuale utente v1.0 IT
Indice Italiano
GESTIONE DELL’IMPIANTO DA APP
1. REGISTRARE L’APP 10
2. ASSOCIARE LA CENTRALE 11
3. GESTIRE L’IMPIANTO 11
4. VIDEOVERIFICA 13
5. ALTRE FUNZIONI 14
6. SPAZIO PER L’INSTALLATORE 14
INFORMAZIONI GENERALI
1. NOTE IMPORTANTI 15
2. CONTENUTO DELLA CONFEZIONE 15
3. INSTALLAZIONE 15
4. CONFORMITÀ 15
5. STANDARDS 15
6. COSTRUTTORE 16
7. SPECIFICHE 16
8. GARANZIA 16
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Idiomas:
Otros manuales de Panel de control de AMC