Safety Notes
Review the drawings and illustrations contained in this manual before proceeding. If there are any questions regarding
the safe installation or operation of the system, contact Alpha Technologies or the nearest Alpha representative. Save this
document for future reference.
To reduce the risk of injury or death and to ensure the continued safe operation of this product, the following symbols have
been placed throughout this manual. Where these symbols appear, use extra care and attention.
The following sections contain important safety information that must be followed during the installation and maintenance
of the equipment and batteries. Read all of the instructions before installing or operating the equipment, and save this
manual for future reference.
There may be multiple warnings associated with the call out. Example:
ATTENTION provides specic regulatory/code requirements that may affect the placement of equipment and /or
installation procedures.
ATTENTION:
NOTE provides additional information to help complete a specic task or procedure.
NOTE:
ELECTRICAL HAZARD WARNING provides electrical safety information to PREVENT
INJURY OR DEATH to the technician or user.
WARNING! ELECTRICAL HAZARD
FUMES HAZARD WARNING provides fumes safety information to PREVENT INJURY OR
DEATH to the technician or user.
WARNING! FUMES HAZARD
FIRE HAZARD WARNING provides ammability safety information to PREVENT INJURY OR
DEATH to the technician or user.
WARNING! FIRE HAZARD
This WARNING provides safety information for both Electrical AND Fire Hazards
WARNING! ELECTRICAL & FIRE HAZARD
CAUTION provides safety information intended to PREVENT DAMAGE to material or equipment.
CAUTION!

3041-135-B0-001 Rev. A (07/2013)
AlphaGen DCX2000
36VDC Portable Generator
Operation Manual
041-135-B0-001, Rev. A
Effective Date: July 2013
Copyright 2013
Alpha Technologies, Inc.
Contacting Alpha Technologies: www.alpha.com
or
For general product information and customer service (7 AM to 5 PM, Pacic Time), call
1-800-863-3930
For complete technical support, call
1-800-863-3364
7 AM to 5 PM, Pacic Time or 24/7 emergency support
member of The Group
TM
Alpha denies responsibility for any damage or injury involving its enclosures, power supplies, generators,
batteries or other hardware, manufactured by Alpha or members of the Alpha Group, when used for an
unintended purpose, installed or operated in an unapproved manner, or improperly maintained.
NOTE:
Photographs and drawings in this manual are for illustrative purposes only and might not exactly match your
installation.
NOTE:
Review this manual before proceeding. If there are questions regarding the safe installation or operation of
this product, please contact Alpha Technologies or your nearest Alpha representative.
NOTE:

4041-135-B0-001 Rev. A (07/2013)
Table of Contents
DCX2000 Portable Generator Safety Notes......................................................................................................... 6
1.0 Introduction............................................................................................................................................... 7
1.1 DCX2000 Generator Components ............................................................................................... 7
2.0 Operation.................................................................................................................................................. 9
2.1 Oil Level ........................................................................................................................................ 9
2.2 Fuel Level ................................................................................................................................... 10
2.3 Air Cleaner .................................................................................................................................. 11
2.4 Power System Connections........................................................................................................ 12
2.4.1 Y-Style Connection........................................................................................................... 12
2.4.2 Ring Lug Style Connection .............................................................................................. 13
2.4.3 Alligator Clamp Style Connection..................................................................................... 14
2.5 Start-Up....................................................................................................................................... 15
2.6 Operation at High Altitude ........................................................................................................... 16
2.7 Operation at Extreme Temperatures........................................................................................... 16
2.8 Engine Shutdown........................................................................................................................ 16
2.9 Output, Alarm and Oil LEDs........................................................................................................ 17
3.0 Servicing................................................................................................................................................. 18
3.1 Emission Control System............................................................................................................ 18
3.2 Maintenance Schedule ............................................................................................................... 20
3.3 Changing Oil ............................................................................................................................... 21
3.4 Air Cleaner Service ..................................................................................................................... 22
3.5 Spark Plug Maintenance............................................................................................................. 23
3.6 Spark Arrestor Maintenance ....................................................................................................... 24
4.0 Transport and Storage Instructions ........................................................................................................ 25
4.1 Transporting the Generator......................................................................................................... 25
4.2 Exercising the Generator ............................................................................................................ 25
4.3 Short Term Storage..................................................................................................................... 25
4.4 Long Term Storage ..................................................................................................................... 26
5.0 Troubleshooting ...................................................................................................................................... 27
6.0 Specications.......................................................................................................................................... 28
7.0 Warranty Information .............................................................................................................................. 29
7.1 California Emissions Control Warranty Statement...................................................................... 29
7.2 Emission Control System Warranty ............................................................................................ 30

5041-135-B0-001 Rev. A (07/2013)
Figures & Tables
Fig. 1-1, DCX2000 Generator Components ......................................................................................................... 7
Fig. 1-2, Engine Serial Number ............................................................................................................................ 8
Fig. 2-1, Oil Level ................................................................................................................................................. 9
Fig. 2-2, Checking Fuel Level............................................................................................................................. 10
Fig. 2-3, Checking Air Cleaner............................................................................................................................ 11
Fig. 2-4, Y-Style Connection............................................................................................................................... 12
Fig. 2-5, Ring Lug Style Connection................................................................................................................... 13
Fig. 2-6, Alligator Clamp Style Connection ......................................................................................................... 14
Fig. 2-7, Start-Up................................................................................................................................................ 15
Fig. 2-8, Recommended Oil By Temperature ..................................................................................................... 16
Fig. 2-9, Fuel Valve ON/OFF Positions .............................................................................................................. 16
Fig. 2-10, Control Panel...................................................................................................................................... 17
Fig. 3-1, Air Quality Index Label ......................................................................................................................... 19
Fig. 3-2, Changing Oil......................................................................................................................................... 21
Fig. 3-3, Air Cleaner Assembly ........................................................................................................................... 22
Fig. 3-4, Spark Plug Maintenance ...................................................................................................................... 23
Fig. 3-5, Accessing the Spark Arrestor ............................................................................................................... 24
Fig. 4-1, Starter Grip........................................................................................................................................... 26
Fig. 5-1, Replace Spark Plug.............................................................................................................................. 27
Table 2-1, LED States......................................................................................................................................... 17
Table 3-1, Maintenance Schedule ...................................................................................................................... 20

6041-135-B0-001 Rev. A (07/2013)
DCX2000 Portable Generator Safety Notes
The manufacturer cannot anticipate every circumstance that may involve a hazard, therefore, these warnings are not
comprehensive.
Engine exhaust contains carbon monoxide gas, which can be deadly in closed or poorly
ventilated areas.
WARNING! FUMES HAZARD
• Generator must be properly grounded.
• Do not make or break any connections while generator is running.
• Do not place or operate the generator in standing water, or expose it to a forced spray of
water.
• Ensure cables do not cross hot surfaces or sharp edges. Inspect cables before and after
each use.
WARNING! ELECTRICAL HAZARD
• Never operate the generator near combustible materials.
• Never refuel the generator in the vicinity of open ames of heat sources. Do not smoke near
the generator.
• Do not refuel the generator while engine is running. Allow generator to cool before refueling.
• Fuel spillage cleanup is the responsibility of the operator and should comply with local codes
and regulations.
• For re safety, the generator must be properly connected, maintained, and in compliance
with applicable codes and regulations.
• Drain oil and empty the fuel tank before transporting. Fuel can leak from the ller cap if the
generator is tilted.
WARNING! FIRE HAZARD
• Prior to each use, inspect the generator for leaks and damage. Immediately repair or replace any
damaged parts.
• The generator must be operated on level ground, not to exceed 15° slant.
• Use only vendor-authorized repair parts.
CAUTION!

7041-135-B0-001 Rev. A (07/2013)
1.0 Introduction
The Alphagen DCX2000 portable DC generator supplies DC voltage to a power supply battery bus when
commercial AC power is not available. The generator is designed to be temporarily connected to the DC bus
of a standard Alpha 36V uninterruptable power supply (UPS). Upon loss of commercial AC power, the existing
batteries immediately supply the power supply inverters. After some interval of battery discharge, an operator
deploys the portable generator at the site to supply power to the DC bus.
1.1 DCX2000 Generator Components
Fig. 1-1, DCX2000 Generator Components
Spark Plug Access Cover
Gas Cap
Control Panel
Starter Grip
Choke Lever
Exhaust Grill
Maintenance
Panel
Fuel
Valve
Fuel Primer
Spark Arrestor
OUTPUT BREAKER
LCD Display
V: 40.3V I: 00.0A
P:0000W
Oil: OK ALM:
Time: 004H 27M
Ground Stud
DC OUTPUT
OUTPUT
ALARM
OIL
ENGINE
ON
OFF
ON
OFF

8041-135-B0-001 Rev. A (07/2013)
1.0 Introduction, continued
1.1 DCX2000 Generator Components, continued
The engine serial number is stamped on the engine block (remove maintenance panel).
Fig. 1-2, Engine Serial Number
11085603
Serial Number

9041-135-B0-001 Rev. A (07/2013)
2.1 Oil Level
Power OFF the generator engine and place on a level surface before servicing.
WARNING! ELECTRICAL HAZARD
• Using non-detergent oil or 2-stroke engine oil will shorten service life and void the warranty. Use only
high-detergent, premium quality, 4-stroke engine oil, certied to meet U.S. automobile manufacturer’s
requirements for API Service Classication SG/SF/SJ/SL/SM/SN. Use synthetic SAE 10W-40
viscosity oil unless operating at ambient temperatures below 32°F (0°C). For temperatures below
32°F, use synthetic SAE 0W-40 viscosity oil.
• Change the oil in a new engine within 4-6 hours of operation to clean any contamination or
manufacturing debris.
• Running the engine with low oil can cause serious damage.
• The Low Oil Alarm System will automatically stop the engine before the oil level falls below a safe
limit. To avoid an unexpected shutdown, inspect the oil level regularly.
CAUTION!
Tools Required:
#2 Philips Head Screwdriver
Oil Drain Pipe
Procedure:
1. Remove the maintenance cover.
2. Using the slots in the oil drain pipe, remove the dipstick, wipe with a clean rag and reinsert, screw
down until tight.
3. Remove the dipstick to check the oil level.
4. If the oil level is below the lower level of the dipstick, rell to the top of the upper level marking. Do not
overll.
5. Reinsert the dipstick and screw down until tight.
2.0 Operation
Fig. 2-1, Checking Oil Level
L
L/2
Dipstick
Oil Fill Hole
Minimum
Oil Level
Maximum
Oil Level

10 041-135-B0-001 Rev. A (07/2013)
2.0 Operation, continued
2.2 Fuel Level
Gasoline is extremely ammable and can be explosive. Refuel in a well-ventilated area
with the engine OFF. Keep all smoking materials, sparks, and other sources of combustion
away from the generator during refueling.
The area must be free of spilled fuel before starting the engine. Avoid repeated or
prolonged contact with skin or exposure to vapor. KEEP OUT OF REACH OF CHILDREN.
WARNING! FIRE & FUMES HAZARD
Only use regular unleaded gasoline with the DCX2000 Generator. The fuel tank has a capacity of 1.7
gallons (6.5 Liters).
Procedure:
1. If the fuel level is low, rell to the top of the fuel strainer.
2. After refueling, tighten the fuel cap securely.
Do not use an alternate fuel blend that contains more than 10% ethanol. Do not use gasoline
containing methanol. An octane rating of 87 or higher is recommended. Fuel system damage or engine
performance problems resulting from the use of fuels that contain an improper alcohol blend are not
covered under warranty.
CAUTION!
Fig. 2-2, Checking Fuel Level
Fuel Cap