MOUNTING PRECAUTIONS FOR TRACK-ARM AND PULL-SIDE OPERATORS:
The sensor must be mounted so that it doesn’t “see” the track. Position the
mounting template on the door so that the sensor is below the track. Bend
or fold the template around the track as needed. Ensure the sensor on the
opposite side of the door is at the same level as the one on the track side.
If mounting between the track and door edge on the Senior Swing, ensure the
optical window is below the track. On the other LCN track operators, the sensor
must mount below the track since there is no room between the track and the
edge of the door.
Center-pivoted doors: Mount more towards the latch edge of the door to
prevent damage to the sensor occuring between the door and door frame.
Mounting Extensions (10MICROSCANMOUNT, sold separately) may be helpful
in these applications.
Page 4 of 16 75.5927.08 ALLEGION LZR-MICROSCAN T 20200312
* SURVEY THE DOOR:
- Verify that the door control and operator is functional and operational before beginning.
- Check BOTH sides of the door for the following: distance from pivot edge, distance from the top of
the door, frame clearance, finger guard, door arm, etc. Check that the location is clear and free of any
obsutrctions.
* SENSOR LOCATION IS IMPORTANT: It is best practice to mount the sensors as close to the top of the door.
Mounting height from finished floor to the sensor LED must be within the range of 75" to 98".
* USE A SPACER (70.5554), IF NECESSARY: Be sure to use a spacer when door hardware protrudes more than
one inch from the door face.
* USE A MOUNTING ARM, IF NECESSARY: Be sure to use the Mounting Arm kit when mounting on a narrow-
style aluminum door. Refer to Mounting Template 75.5908 when using the Mounting Arm kit.
* HOLE SIZE: Be sure to comply with hole sizes called out on the Mounting Template.
* LZR-MICROSCAN T SENSORS AND MOUNTING ARM ACCESSORIES ARE HANDED. PLEASE OBSERVE
WHEN MOUNTING.
A) INSTALL MOUNTING ACCESSORIES (IF REQUIRED)
NOTES
I. INSTALLATION
• If a mounting arm is needed for this application, align the Mounting Template (75.5908) in the desired
location, and mark and drill the required holes.
»If a spacer is also required for this application, secure the spacer to the mounting arm, and then
secure the sensor to the spacer.
»If no spacer is required for this application, simply secure the sensor directly to the mounting arm.
• If a spacer only is required for this application, mark and drill the SPACER MOUNTING HOLES on
Mounting Template (75.5754), and then simply secure the sensor directly to the spacer using the
SENSOR MOUNTING HOLES.
IMPORTANT:
• All wiring harnesses used must a) be routed separate from any mains or non-class 2 voltage
cables, or b) be rated for the mains voltage and suitable protection.
• Routing means must be used in accordance with national and local codes.
mounting arm spacer mounting arm with spacer