Alarko HARMONY - D Guía del usuario

1
USERS, INSTALLATION
AND SERVICING
INSTRUCTIONS
HARMONY – D

2
Code No: A.1.2.8i Publishing Date:200114
Revision Date: 200114

3
Thank you for choosing ALARKO brand.
This booklet covers room sealed model HARMONY-D natural gas/LPG
combination boilers in ALARKO-CARRIER boiler range.
In this booklet you will find the instructions for use in USE section and
instructions for installation and maintenance in INSTALLATION AND
MAINTENANCE section.
For long-term and safe use of the boiler, the user must read the USE
section of this booklet carefully before using the boiler. Other sections of
this booklet are not for the end-user.
People or organizations authorized to install, commission and service
this boiler must follow the instructions in INSTALLATION AND MAIN-
TENANCE section of this booklet to ensure the correct installation and
operation of the appliance.
For further information, please consult to the product introduction broc-
hure or authorized dealers and services.
Keep this booklet on hand to consult to whenever you may need.

4
..
TABLE CONTENTS
USER INSTRUCTIONS 8
1. Introduction 8
DECLERATION OF CONFORMITY AND CERTIFICATION 9
TERMS AND CONDITIONS OF GUARANTEE AND SERVICE 9
Guarantee is not valid under below conditions. 9
1.1 Gas Safety 10
1.2 Course of Action in case of Gas Leakage 10
1.3 Contents of Packaging 12
2. Product Description 13
2.1 Technical Data 15
2.2 Dimensions 16
2.3 Internal Parts of the Boiler 17
2.4 Water Circuit 18
2.5 Control Panel 19
2.5.1 ON/OFF and Domestic Hot Water Control Knob 19
2.5.2. Central Heating Control Knob 20
2.5.3. Pressure Gauge (Manometer) 20
2.5.4. LCD Display 21
2.5.5. Reset Button 21
3. BOILER OPERATION 22
3.1 Start-Up / Pre-Checks 22
3.2 Water Filling 22
3.3 Domestic Hot Water Operation 23
3.4 Central Heating Operation 23
In Summer:
3.5 Turning the boiler OFF 24
3.6 Central Heating System Discharge 24
3.7. Topping-up the system with water 24
INSTALLATION AND SERVICING 24
4. INTRODUCTION 25
4.1 INSTALLATION RULES 25
4.1.1 GENERAL 25

5
4.1.2 BOILER LOCATION 26
4.1.3 AIR SUPPLY 27
4.1.4 OPENING THE PACKAGE & TRANSPORT 28
4.1.5 MOUNTING THE BOILER 29
4.1.6 Water and Gas Connections to the Boiler: 29
4.2 FLUE SYSTEM AND INSTALLATION 30
4.2.1 Sitting the Flue Terminal 30
4.2.2 Parts of Harmony_D RSF Flue System 33
4.2.3 Standard Supply (concentric horizontal) 34
4.2.4 Additional Kits 34
4.2.5 Installing the Standard Supply 37
4.2.6 Installing the Flue System with Straight Extension Kit: 38
4.2.7 Installing Flue System with 90° Turning Kit 41
4.2.8 Installing Flue System with Elevation Kit 42
IMPORTANT NOTES ON FLUE SYSTEMS 44
4.3 COMPONENTS & SYSTEM 44
4.3.1 Filling the system 45
4.3.2 DOMESTIC HOT WATER 46
4.3.2.1 Showers, Bidets, Taps and Mixing Valves 48
4.3.2.2 Water Quality 48
4.3.2.3 Water Pressure 48
4.4 ELECTRICAL 49
4.4.1 ELECTRONIC BOARD WIRING DIAGRAM 51
4.5 CONVERSION TO DIFFERENT GASES 52
5. OPERATING PARAMETERS 53
5.1 Programming operating parameters 54
5.1.1 Parameter menu activation 54
5.1.2 Parameter selection mode 55
5.1.3 Parameter changing mode 55
5.1.4 PARAMETERS’ ADJUSTMENT 56
5.1.4.1 Parameters Menu Activation 56
5.1.4.2 Parameter Selection 57
5.1.4.3ParameterModication 57

6
5.2 OPERATING ERRORS 57
5.2.1 Some Typical Problems 58
5.3 PERIODIC MAINTENANCE 59
Automatic Control Devices 60
6. Use with LPG 61
7. COMMISSIONING 61
7.1 Pre Checks 61
7.2 Start up 62
7.3 Setting The Heat Input 63
7.4 Maximum and Minimum DHW/CH Input Adjustments
(mechanical maximum and minimum) 64
7.5 Final Operational Checks 65
7.6 Commissioning – Heating System 65
7.7 INSTRUCTIONS TO THE USER 66
8. SERVICING 66
Appendix A 70
FAULT FINDING 70
TABLES
Table 1 Technical Data 15
Table 2 Clearances for boiler installation 26
Table 3 Minimum clearances for cupboard installation. 27
Table 4 Minimum ventilation areas for cupboards 28
without sufficient clearance.
Table 5 Setting the Parameters 53
Table 6 Parameter Adjustment 55
Table 7 Fault Display 57

7
FIGURES
Figure 1 Boiler Dimensions 16
Figure 2a-b Main Parts of the Boiler/ Front-Backside View 17
Figure 3 Water Circuit Diagram 18
Figure 4 Control Panel Appearance 19
Figure 5 DHW Knob 19
Figure 6 CH Knob 20
Figure 7 Manometer 20
Figure 8 LCD Display Screen 21
Figure 9 Hydraulic Group- Manual filling tab 24
Figure 10 Transport & Packaging 28
Figure 11 Mounting Schematic with essential dimensions. 29
Figure 12 Gas & Water Connections 30
Figure 13 Flue Terminal Dimensions 32
Figure 14 The Parts of the Flue Kit 33
Figure 15 Wall Connections 36
Figure 16 Extensions & Elbow 36
Figure 17 Standard Flue Kit Installation 37
Figure 18 Extension Flue Kit Installation 39
Figure 19 Shortening the Ducts 40
Figure 20. 90º Turning Kit Installation 41
Figure 21. Elevation Kit Installation 43
Figure 22 a) Additional Expansion Vessel, b)
Methods of Filling the System 45
Figure 23 Volumetric Flow Rate & Pressure Difference
Relation for the Circulation Pump 46
Figure 24 Main Board Diagram 51
Figure 25 Burner Pressure/ Heat Input Diagram 63
Figure 26 Gas Modulator 64
Figure 27 Burner Plates, Igniters and Flame Sensors 68

8
Inthisbookletyouwillndusersandservicinginstructionsofyournew
Harmony – D digital screen combination boiler and some useful infor-
mation and technical data about it. Harmony combination boilers are
the results of development, production and marketing experience, which
have resulted in the current highly efcient and user-friendly models.
Thecompactsizeandpleasingappearanceenablethemtobettedin
a wide range of locations. Despite its compactness, all inner pipe-work
and components are designed to allow easy access for the service en-
gineer.
The appliance is suitable for sealed systems only.
Our authorized seller and services will give you the enough information
about use and maintenance after setting up the boiler. You can ask any
further question to them. Our experts will be glad to answer your ques-
tions.
Inordertousetheboilerinsafe,highefciencyandeconomicwayfor
a long life period; please read these instructions carefully and obey the
safety rules and warnings.
In addition to the users instructions in this booklet, there are also techni-
cal data and introductory information about the boiler.
Read the instructions and other labels carefully, before starting the
boiler.
Take into consideration all the warnings.
Do not handle the parts of the boiler in a different way than speci-
ed in the instructions.
USER INSTRUCTIONS
1. Introduction

9
DECLERATION OF CONFORMITY AND CERTIFICATION
Alarko Carrier manufacture boilers referred to in this booklet are pro-
duced in conformity with below: EC Directives and can hold the CE mark.
2009/142/EC Gas Appliances Directive
92/42/EECEfciencyDirective
2004/108/EC Electromagnetic Compatibility Directive
2006/95/EC Low Voltage Directive
TheappliancesarecertiedtocomplywiththerequirementsofEN297,
EN 483 and EN 625 using the gas categories listed below:
2H and 2E; G20 gas with a governed gas supply at 20 mbar inlet pres-
sure
3 B/P; any mixture of G30 and G31 gases with a governed gas supply
at 29-mbar-inlet pressure 3+; G30 / G31gases with non-governed gas
supplies at 29 / 37 mbar inlet pressures, respectively.
TERMS AND CONDITIONS OF GUARANTEE AND SERVICE
Your boiler is guaranteed for material defects and mechanical failure as
written on the Guarantee Form.
The guarantee is only valid if the appliance is installed in accordance
with this manual.
Guarantee is not valid under below conditions.
• Installationbyunauthorizedpersons.
• Hazardsduetoservicebyunauthorizedpersons.
• Hazardsduetonaturaldisaster.
• Hazardsduetobadweatherconditions,especiallyfrost,unlessin-
structions in this booklet are obeyed.
• Damagedorchangedserialnumberofboiler.
• Incorrectinstallation,useandmaintenancewithrespecttothein-
structions and the regulations in force.
• Boilersproducedfordisplayandexhibitionpurposes.

10
• AbsenceofGuaranteeForm.
• Thetransportationrisksbelongtothecustomerifboilerissentto
service by customer and belongs to the service if boiler is taken
by service.
1.1 Gas Safety
It is the law that all gas appliances must be installed by a competent
person in accordance with the current rules and regulations in force
in the country of destination. With the same scope, any gas conver-
sion process carried out on the boiler must be done by a competent
person as well.
TheseappliancesarecertiedtocomplywiththerequirementsofEN
483 and EN 625 using gas categories 2H, 2E, 3B/P, 3+, 3B and 3P
with prescribed gas inlet pressures. No other gas use condition is al-
lowed for the boiler.
The particular gas type that the boiler is already adjusted to is written
on its data badge, unless it is converted to another gas by a compe-
tent person. Make sure that the boiler is not used with a different gas,
otherthanwhichitisadjustedfororitisnallyconvertedto.
1.2 Course of Action in case of Gas Leakage
If you smell gas or the gas alarm device signals;
• Becalm,
• Turnofftheappliance,
• Openallthedoorsandwindowstoventtheroom,
• Extinguishanyame,
• Closegasvalvesofanyapplianceandattheapartmentinlet,
• Donotlightanythinganddonotsmoke,
• Donotswitchonoroffandelectricaldevice,
• Donotattachorpulloutelectricplugs,donotringthebell,
• Donotusethetelephonewherethegassmellexists,
• Contactyourgassupplierandrebrigadeandexplainthesitua-
tion.
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Caldera de Alarko

Alarko
Alarko CGS3 Series Manual de usuario

Alarko
Alarko ADK 200 Manual de usuario

Alarko
Alarko ACK2 Manual de usuario

Alarko
Alarko SERADENS SUPER PLUS SSP 20 Manual de usuario

Alarko
Alarko SRS 20 Manual de usuario

Alarko
Alarko ALDENS F-175 Manual de uso y cuidado

Alarko
Alarko SUPER FIT 24 Manual del propietario

Alarko
Alarko SERADENS SRD 20 Instrucciones de montaje