AiSight Aion Manual de usuario

1
Gertraudenstraße 10-12, 10178 Berlin
Email: info@aisight.de
Phone: +49 (0) 30 40363399 V1.0
1
Service and installation
instructions
AiSight Aion

2
Gertraudenstraße 10-12, 10178 Berlin
Email: info@aisight.de
Phone: +49 (0) 30 40363399 V1.0
2
Summary
Summary 2
Introduction 3
1. Definitions and Glossary 3
2. Proper Handling 5
1.1. Caution and Warnings 6
1.2. Risk Assessment 6
1.3. Compliance 6
1.3.1 FCC Compliance Statements 6
1.3.2 ISED Compliance Statements 7
3. Service and installation instructions 8
3.1. Mounting 8
3.2. Powering 10
3.2.1. Powering with the AC Power Supply 11
3.2.2. Powering with DC cable 11
3.2.3. Cable Management 11
3.3. Connecting 13
3.3.1. Required parts 13
3.3.2. Sensor Node Overview 13
3.3.3. Wi-Fi Requirements 13
3.3.4. Provisioning 13
4. Notes and Version Control 19

3
Gertraudenstraße 10-12, 10178 Berlin
Email: info@aisight.de
Phone: +49 (0) 30 40363399 V1.0
3
Introduction
Aion measures vibration, geomagnetic, and temperature data of your machine. The sensor
picks up the vibration data of your machine which is then sent to our cloud. As a result, we
can detect anomalies and faults in your machine and prevent bigger failures. Once a
significant fault is detected you will get notified and you will be able to repair the damage in
time without needing to stop the full production.
In order for us to give you the best and most accurate results, it is very important that you
carefully read and understand the instruction manual.
1. Definitions and Glossary
Package: The package received by the client is a recycled paper box that includes the
sensor node, power supply, and mounting interfaces.
Sensor Node: across this document, the words “Sensor Node” will be used to refer to the
AiSight Sensor Node (Aion).
Power Supply: The 90~240VAC to 24V power supply to power up the sensor with
24VDC.
Power Cable: The cable with M8 4 pins connector to power up the sensor directly from
24V from machine panels or other local DC power sources.
MAC Address: Unique identifier number for each sensor node, known as serial number.
Mounting Interface: the mounting interface is any mechanical and/or chemical combination
to attach the sensor node to the machine.
Bluetooth Low Energy (BLE): is a low power consumption wireless technology standard
used for exchanging data between fixed and mobile devices over short distances using
short-wavelength UHF radio waves.
WiFi Network: is a wireless technology standard used for exchanging data between fixed
and mobile devices over medium-range distances with higher data rates, also providing
access to the internet.
Provisioning Application (App): it is a smartphone application that connects with the
sensor node via BLE to input the WiFi credentials.
Dashboard: web application used to access the machine status, features, and anomalies.
User: end client of the Aion.
Cloud: where the user’s vibration, geomagnetic, and temperature data will be stored.

4
Gertraudenstraße 10-12, 10178 Berlin
Email: info@aisight.de
Phone: +49 (0) 30 40363399 V1.0
4
This manual contains the requirements for the correct installation, provisioning, and
operation of Aion designed for the sole purpose of condition monitoring.
The Aion is designed for, and must only be handled and installed by trained personnel.
Not following this manual may cause malfunction of the sensor node, unprecise anomaly
detection, damage to the machines and to the environment.
Any abnormal behavior or defect on Aion must be informed immediately to AiSight, who will
provide maintenance or replacement of the sensor node.
The user is not authorized to open or to perform any maintenance actions on the sensor node
and power supply.

5
Gertraudenstraße 10-12, 10178 Berlin
Email: info@aisight.de
Phone: +49 (0) 30 40363399 V1.0
5
2. Proper Handling
Proper handling of AiSight Aion Sensor Node is critical to prevent any damage.
The following hazard situations should be avoided:
●To drop the item
●Hit the item against sharp or hard surfaces
●Touch the pins of the connector of the Aion connector or its power supply with any
metal tools or conductive devices
●Use excessive force when mounting the unit
●In case of the use of magnet accessory:
●avoid impact (due to magnetic attraction) when mounting the sensor on the
desired surface.
●do not put any operator body parts between the magnet and metal surfaces
●In case of use of swivel mounting, force the mounting without the presence of a
thread
●Expose the item to temperatures above 90°C
●Expose the item to any reactive chemicals
●In the case of using the power cable instead of the power supply, only trained
electricians can handle the installation of the cable
The user’s Environmental, Health, and Safety (EHS) manager has to be consulted to ensure
a safe installation of the sensor. The technicians who are responsible for the installation must
follow all EHS guidelines, use the required Personal Protective Equipment (PPE) and use the
proper and indicated tools.
For adhesive mounting options, the cure time must be respected before the operation of the
machine restarts.
The power supply cable or the power cable alone must be securely tied to fixed parts of the
body of the machine, cable trays, or ducts. It's suggested to use cable ties, clips, and clamps.

6
Gertraudenstraße 10-12, 10178 Berlin
Email: info@aisight.de
Phone: +49 (0) 30 40363399 V1.0
6
1.1. Caution and Warnings
Caution indicates a hazard that could cause minor personal injury, or
property damage if ignored.
A warning indicates a hazard that could cause severe personal injury, death,
or substantial property damage if ignored
1.2. Risk Assessment
The risk assessment of the sensor is based on the CENELEC GUIDE 32 and it can be shared.
Please contact AiSight if you need any further information.
1.3. Compliance
1.3.1 FCC Compliance Statements
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received, including interference that
may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Note:
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
!
!

7
Gertraudenstraße 10-12, 10178 Berlin
Email: info@aisight.de
Phone: +49 (0) 30 40363399 V1.0
7
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
1.3.2 ISED Compliance Statements
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation,
Science and Economic Development Canada’s license-exempt RSS(s).
Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause
undesired operation of the device.
In accordance with the Canadian requirements (RSS-102, 2.6) a minimum distance of 20cm
must be kept between the device and the user during service.
Le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement
économique Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes:
1. L’appareil ne doit pas produire de brouillage, et
2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
Conformément aux exigences canadiennes (RSS-102, 2.6), une distance minimale de 20cm
doit être maintenue entre l'appareil et l'utilisateur pendant les opérations.

8
Gertraudenstraße 10-12, 10178 Berlin
Email: info@aisight.de
Phone: +49 (0) 30 40363399 V1.0
8
3. Service and installation
instructions
In order to successfully install Aion and directly read the data on the AiSight dashboard
three steps are needed:
1. Mounting: Mount Aion on the desired machinery
2. Powering: Connect Aion to power
3. Connecting: Provision the sensor to wifi
4. Operating. Read data from AiSight Dashboard
The steps that MUST be performed by qualified personnel are 1. Mounting
and 2. Powering.
3.1. Mounting
The Aion is a three axial vibration and geomagnetic sensor. The axes for both
measurements are configured as shown in Figure 4.1. The “x” axis is aligned with the logo,
while the “y” is aligned with the M8 connector. The “z” axis covers the resulting dimension,
perpendicular to the body of the sensor. The Aion can be installed on Motors, Pumps or
Gearboxes through the magnet on its back.
Figure 4.1 - Sensor orientation
X
Z
Y
!

9
Gertraudenstraße 10-12, 10178 Berlin
Email: info@aisight.de
Phone: +49 (0) 30 40363399 V1.0
9
The first step is to identify the ideal mounting position on the machine. As we are
measuring the vibration of the machine and we rely on very good transmission of the data it
is not recommended to attach the sensor anywhere on the machine. Ideally, if a probable
failure location is known, it is recommended to place the sensor as close as possible to it.
Steps
1. Identify the best monitoring position on the machine
2. Start by cleaning the surface of your machine with the cleaner and the cloth. Be sure
no dirt is remaining
3. Sand the surface to improve the mounting process and then clean the surface again
from sanding residuals
4. Carefully slide out the protective metal ring from the magnet with the help of pliers
5. Apply the Aion on the previously prepared surface
For additional information regarding the mounting of Aion, please contact AiSight.
Safety Precautions
The magnet on the back of the Aion is very strong, and it is mandatory to
take exceptional care with handling it in the vicinity of magnetic surfaces and
the user's fingers.
!

10
Gertraudenstraße 10-12, 10178 Berlin
Email: info@aisight.de
Phone: +49 (0) 30 40363399 V1.0
10
3.2. Powering
Two options to power up the sensor can be used depending on how the customer prefers
and how the contract between the two parts was agreed. The first option is to use the custom
AC power supply compatible with the product, the TRE25R240 with 3m long cable and
female M8 4 pin connector, as shown in Figure 4.3.
Figure 4.3 - AiSight custom power supply with M8 connector
In cases where AC connection is not possible close to the machine (either by physical or
safety constraints) the customer can also use a 2-wire or 4-wire cable with M8 4-pin female
connector to directly connect the sensor node from existing machine panels or switchboards
that has DC connection from 8 to 48V (24V recommended). A cable with an overmolded
connector can be used or a cable with a field installable connector, as shown in Figure 4.4.
For either case, the cable must be designed for industrial use, have internal and external
insulation jackets and have the UL94-V0 or higher.
The sensor node consumes a maximum of 3W and supports a power supply voltage from 8
to 48Vdc, with a preferred supply of 24Vdc.
Figure 4.4 - Example of a cable with M8 female plug connector
Otros manuales para Aion
2
Tabla de contenidos
Otros manuales de Sensor de seguridad de AiSight