Airflow Adroit DV110 Manual de usuario

DV110
(Integral CO2Sensor)
Instruction Manual
INSTRUCTION MANUAL
DV110 (Integral CO2Sensor)

2
DV110 (Integral CO2Sensor)
INSTRUCTION MANUAL

3© Airow • We reserve the right to make changes without prior notice
DV110 (Integral CO2Sensor)
CONTENTS
INSTRUCTION MANUAL
1. INTRODUCTION
● Main parts of the ventilation unit
● System description
● General safety instructions
● Adroit digital controller
● Starting up and shutting down the unit
2. INSTALLATION
●Installationandmounting
●Airowmeasuringtubes
●Dimensionsandductoutlets
●Condensingwateroutlet
3. MAINTENANCE
● Filters
● Heat recovery cell
● Fans
● Condensatedrain
● Troubleshooting
4. TECHNICAL SPECIFICATIONS
● Technicalspecications,inputpowers,airvolumes,soundvalues,fancurves,
dimensions,ductoutletsandmeasurementpoints
● Internal electrical connection
● External electrical connection
5. CERTIFICATE OF CONFORMITY
6. EXPLODED VIEW AND PARTS LIST
7. COMMISSIONING THE SYSTEM
8. WARRANTY
4
10
14
20
25
27
28
28
NOTE:
You can sign into your Adroit account at: www.airowadroitcontrol.com

4
DV110 (Integral CO2Sensor) INTRODUCTION
INTRODUCTION
NOTE Formoredetailedinstructions,gotowww.airow.com
INTRODUCTION
R model in the figure
5
11
12
13
3
1
6
4
14
15
2
7
8
9
10
A
N
N
U
A
L
E
F
F
I
C
I
E
N
C
Y
R
A
T
I
N
G
O
F
E
X
T
R
A
C
T
A
I
R
H
E
A
T
R
E
C
O
V
E
R
Y
A
+
MAIN PARTS OF THE VENTILATION UNIT
Extract air fan (behind the protective cover)
1
Supply air fan (behind metal duct pipe)
2
Fine filter for supply air
3
Heat recovery cell
4
Heat Recovery cell bypass damper
5
Coarse filter for supply air
6
Coarse filter for extract air
7
Post-heater (Optional)
(behind the extract air duct)
8
Electrical safety cut off switch 9
Internal humidity sensor 10
Internal carbon dioxide sensor 10
Digital Controller (optional)
11
Humidity sensor (optional)
12
Carbon dioxide sensor (optional) 13
VOC sensor (optional) 14
Cable gland 15

5© Airow • We reserve the right to make changes without prior notice
DV110 (Integral CO2Sensor)
INTRODUCTION
INTRODUCTIONINTRODUCTION
SYSTEM DESCRIPTION
Router
WLAN/
LAN
WLAN
%
VOC
S
away
from
home
Adroit Cloud
Adroit Adroit Control
Adroit Home
WLAN
INTERNET
WLAN / LAN
SENSORS
EXTERNAL
SWITCHES
ROUTER
MODBUS
HOME
AWAY
BOOST
CUSTOM
CONNECTING WITH ADROIT HOME
1. Connect Adroit unit to the mains.
2. Connect one end of the network cable (RJ-45) to computer
and the other end to network connector on the Adroit unit.
3. Select on your computer: Start ► Computer ► Network
4. Double click on the Airow icon. Under Other Devices,
double click the device with a name starting “airow” e.g.
“airowB057A632Af42” (this is the MAC address).
5. Now you are connected to the Adroit Home service, you are
able to control the Adroit unit.
REGISTERING TO THE ADROIT CLOUD
1. ConnectwithAdroitHome(instructionabove).
2. SelectSettings.
3. PressconnectbuttoninAdroitCloudServicesection.
4. RegistrationPageisnowopened.
5. Enterthefollowinginformation
a.Devicename-enterthedesirednameforthedevice
b.Username
c.E-mailaddress
d.Password
6. Pressthecreateaccountbutton.
7. Ane-mailwithyourlog-indetailswillbesenttothee-mailgiven
duringtheregistrationprocess.
8. Avericatione-mailwillbesenttothee-mailaddressgivenduring
theregistrationprocess.
9. Clickonthelinkgiveninthise-mailtoverifyyoure-mailaddress.
10.YouarenowconnectedtotheAdroitCloud.
NOTE
Following requirements:
Firefox,version31orhigher
Opera,version25orhigher
Chrome,version31orhigher
Safari,version7orhigher
Thelastestbrowserversionson
mobiledevices.
NOTE
TheAdroitunitcanalsobe
connectedbynetworkcabletoa
router.InthiscasetheAdroitunit
canbecontrolledviayourlaptop,
tablet,smartphoneetcusinga
networkcreatedbytherouter.

6
DV110 (Integral CO2Sensor)
INTRODUCTIONINTRODUCTION
INTRODUCTION
GENERAL INFORMATION ABOUT THE UNIT
• DV110Adroitunitscanbeequippedwitheitheroneortwo
optionalelectricpostheaters.(900W;900W+900W)
Mounting options:
• Unitsuppliedwithwallmountingbracket;optionalceilingmount
available.Theseunitscanalsobeoormountedifraisedupto
giveclearanceforcondensatedrain.
GENERAL SAFETY INSTRUCTIONS
Forsafeandproperhandling,itisnecessarytoknowthebasicsafety
regulationsandtheintendedusageoftheventilationsystem.Readthis
manualbeforeoperatingtheventilationunit.Keepthismanualforlater
use.Incaseofloss,youcandownloadthemanualfromourwebsite.
This user manual contains all important tips for operating the system
safely.Thisusermanualmustbeobservedbyallpersonswhooperate
andmaintaintheventilationsystem.
Furthermore,observealllocalhealthandelectricalsafetyregulations.
INTENDED USE
AllAdroitunitshavebeendesignedtoprovide
appropriateandcontinuousventilation,insucha
waythatpeopleandstructureswillremainhealthy.
IMPORTANT
Forfurtherinformation,goto
www.airow.com

7© Airow • We reserve the right to make changes without prior notice
DV110 (Integral CO2Sensor)
INTRODUCTION
INTRODUCTION
NOTE
TheAdroitDigitalControllercontains
thebuttonsdescribedinthefollowing
table.Youcanpressthegraphical
userinterfacebuttonsbyusing
thering-shapedbuttonsbelowthe
controller.Thecontrollerdoesnot
haveatouchscreen.
INSTALLATION
Installationandsetupshouldbecarriedoutbycompetentperson.
Electricalinstallationsandconnectionsmustonlybecarriedout
byanelectricianandaccordingtothelocalregulations.
ADROIT DIGITAL CONTROLLER
Note:Optiondescriptioncanbesetbythebuttonbelowthe
displayedimage.
Change prole.Allowsyoutoscrollthroughthe
ventilationproles.
Prole Information.Allowsyoutoviewthecurrently
activeproleinformation.
Temperature.Displaysinformationontemperatures
andsensors.
Settings.Opensindividualsettings.
Back.Takesyoubackwardsinthemenu.
Left arrow.Allowsyoutoscrolltotheleftthroughthe
menusettings.
Right arrow.Allowsyoutoscrolltotherightthroughthe
menusettings.
OK.Allowsyoutoaccepttheselectedoption.
Select.Allowsyoutoselectanoptionfromtheshown
menu.
Edit.Allowsyoutoeditsettings.
Plus.Allowsyouto:
Increasethevalueoftheselectedsetting.
Movetothenextmenuitem.
Movefromaone-dayviewtoaweekviewinthe
temperature,relativehumidityofairandcarbondioxide
levelgraphs.
Minus.Allowsyouto:
Reducethevalueoftheselectedsetting.
Returntothepreviousmenuitem.
Movefromaweekviewtoaone-dayviewinthe
temperature,relativehumidityofairandcarbondioxide
levelgraphs.
Up arrow.Allowsyoutoscrollupwardsinthemenu.
Down arrow.Allowsyoutoscrolldownwardsinthe
menu.
Statistics.Allowsyoutoopenthetemperature,relative
humidityofairandcarbondioxidelevelgraphs(1dayor
1week).
Indicatethechosenuserlevel.
Indicateswhenthefeatureislockedatyouruserlevel.
Theparentalcontrolslockcodeis1001.
DISPLAYED
IMAGE OPTION DESCRIPTION

8
DV110 (Integral CO2Sensor)
INTRODUCTION
INTRODUCTION
INTRODUCTION
Ventilationhastobeconstantfortheindoorairtostayhealthy
forthebuilding’soccupants.Evenforlongerholidays,itisnot
advisabletostoptheventilation,becausetheindoorairwillbecome
stuffyandduringtheheatingseason,theindoorairhumiditymay
condenseintheventilationductworkandstructures,causing
moisturedamage.
Youcancontrolandautomatetheventilationunitoperationinthe
following ways:
• ByusingaDigitalControllerinstalledinthebuilding
• ThroughtheAdroitHomelocalnetworkconnectionandthe
Webinterface
• ThroughtheAdroitCloudServiceandtheWebinterface
• Througharemotemonitoringserviceorbuildingautomation
system(BMS)byusingvoltagesignalsorModbusmessages
Therequiredventilationmayalsobeadjustedautomaticallywith
theoptionalroommountedbetweencarbondioxideandhumidity
sensors.Inthiscase,ventilationremainsoptimalevenifthe
dwellingisunoccupied.
Byusingtheweekclock,youcancreatejusttherightventilationfor
yourindividuallifestyle.
WARNING
Theunitisnotintendedforusebychildren(under8years)orby
personswithreducedsensory,physical,ormentalcapabilities,or
lackofknowledgeandexperiencethatlimitthesafeoperationof
theunit.
These people can use the product under the supervision of a
personresponsiblefortheirsafetyorasdirected.
TIP
TheAdroitDigitalControllerautomaticallyswitchestosleepmode
whenthepre-setsleeptimehaselapsed.Youcanwakeupthe
AdroitDigitalControllerbypressinganycontrolbutton.

9© Airow • We reserve the right to make changes without prior notice
DV110 (Integral CO2Sensor)
INTRODUCTION
INTRODUCTION
Each ventilation unit has two control settings
available,basicandexpert.Thebasicsettingsare:
• Userinterfacelanguage.
• Timeanddate.
The expert settings are:
• Systemadministratorpassword.Theinstaller
has given you the system administrator
password.
• Possibleparentalcontrols.
• Fansettings.
• Userprolesettings,suchasthetemperature.
Settingscanbechangedatalaterdateifrequired.
STARTING THE UNIT
Ifyouarestartingtheventilationunitforthersttime
orafteranymaintenanceprocedure,whentheunit
startsup,thediagnosticdisplaywillappearfora
fewsecondsuntiltheAthomeprolemainscreenis
opened.
Iftheunitisswitchedofffromthecontroller,youcan
restarttheventilationunitbypressinganybuttonon
thecontroller.
We recommend that the latest version always to
beused.Checkanddownloadthelatestversionat
https://www.airowadroitcontrol.com/eitherbeforeor
immediatelyaftersetup.
The current software version of the ventilation unit
is shown on the controller display when the unit
is connected to the mains or factory settings are
restored.Alternatively,thecurrentsoftwareversion
canbecheckedfromtheUnitinformationdisplayof
theServicemenu.
UPDATING THE UNIT SOFTWARE
Disconnecttheventilationunitfromthemains
electricalsupply.orturnoffthefuse.
Connectthecomputertothedigitalcontrollerofthe
ventilationunitusingaUSBMicroBconnector.
Starttheventilationunit.AUSBsignwillappearon
thedisplayofthecontroller.Thecontrollercannotbe
usedwhenitisconnectedtothecomputer.
NOTE
Therstlaunchoftheunitmaytakeawhile,
as the controller will format its software and
verifythatithasthelatestsoftwareversion.
NOTE
However,itisrecommendedthatthe
ventilationbekeptturnedON without
disruptions.
Transfertheupdateleyouhavedownloadedonto
theventilationunit.CopytheupdateleHSWUPD.
BIN
(Pleasenote!Donotalterthelename!)you
havedownloadedattherootofthecontroller(the
controllerwillbedisplayedonyourcomputerasa
massmemoryoraremovablediskdrive).Whenthe
lehasuploadedontothecontroller,removethe
USBcable.Next,thecontrollerwilltakeawhileto
loadtheupdate.Thecontrollerwillnowstarttoload
theupdateleontothemotherboard.Thiscantake
severalhours.Thecontrollerwillremainturnedon,
butitisrecommendedthatthecontrollerwillnotbe
usedduringthattime.Whentheupdateisready,the
unitwillrestartautomatically.
TURNING THE UNIT OFF
Ifyouwanttoturnofftheventilationunit,proceedas
follows:
1. Select Settings > Turn unit off.
2. PresstheOKbutton.
3. Thesystemasksforconrmation.
4. PresstheOKbutton.
5. TheventilationunithasnowbeenturnedOff.

10
DV110 (Integral CO2Sensor)
92
1
Ø6
16
WALL MOUNTING
Notethefollowingbeforemounting:
• DV110Shouldnotbepositionedinanareathatfallsbelow
+10°C.
• Avoidmountingtheunitonahollow,echoingpartitionwallor
onabedroomwall.Takingsoundtransmissionprecautionsis
recommended.
• Theminimumdistancebetweenthetopoftheunitandthe
nishedceilingsurfaceis30mm.Notethatduringmountingthe
unitrises10mmhigherthanthenalheight.
• It is recommended that the unit is not positioned in sound
sensitive areas unless some acoustic deadening measures are
taken.
MounttheDV110onthewallwithamountingbracket,asshownin
theadjacentgure.Makesurethattheunitishorizontallylevelafter
mounting.
MEASURING TUBES
Theaccessorybagwiththeunitincludesfourairowmeasuring
tubes.Thesecanbeinsertedintheductstoallowforeasier
ventilationadjustment.
CEILING MOUNTING BY USING THE
CEILING MOUNTING BRACKET
DV110Adroitunitscanalsobemountedverticallybyusingthe
optionalceilingmountbracket.Attachtheceilingmountingbracket:
• TotheceilingwithM8threadrods,connectingtosuitablemount
pointsthatarestrongenoughtoholdtheweightoftheunit.
• Horizontallylevel,astheplatedeterminesthestraightnessof
theunit.
Insulatetheoutdoorairandexhaustairductagainstcondensation,
aswellasbetweentheunitandtheceilingmountingbracket.
INSTALLATION
INSTALLATION
NOTE
Wheninstallingtheunit,please
considerhavingsufcientspacein
frontoftheunitforservicingpurposes.
DV110Adroit:
The service space in front of the
unitmustbeatleast450mmdeep.
Mount the ventilation unit in a place
where the temperature does not fall
below+10°C.
Otros manuales para Adroit DV110
1
Tabla de contenidos
Otros manuales de Sensor de pernos de Airflow
Manuales populares de Sensor de pernos de otras marcas

alre
alre RFHSS-114.110 Manual de usuario

Crestron
Crestron Closed-Loop Photocell Light Sensor GLS-LCL Cómo utilizar

Zircon
Zircon MultiScanner L350 Manual de usuario

Stanley
Stanley STHT77588 Manual de usuario

Stanley
Stanley S100 Manual de usuario

Applied Physics Systems
Applied Physics Systems 544 Manual de usuario