AirClean systems AC600 Series Manual de usuario

3248 Lake Woodard Drive, Raleigh, NC 27604 USA
Phone: 919-255-3220 • Toll Free: 800-849-0472 • Fax: 919-255-6120
Website: www.aircleansystems.com • Email: [email protected]
* Product designs are subject to change without notice. © 2012 AirClean® Systems
OPERATOR’S MANUAL
DEAD AIR WORKSTATION
AC600 Series Dead Air Box & Timed UV Light
with UVTect™ Controller

2
SECTION PAGE
Warranty 3
Declaration of Conformity 4
Symbols and Denitions 5
Cautions and Precautions 6
Technical Specications 7
Overview 8
Installation Instructions 9
Controller Instructions 11
Programming Menus 12
Operating Instructions 13
Alarm Messages 13
Maintenance:
• Bulbs 14-16
• Cleaning 16
Spare Parts List 16
Options 17-18
Shipping Claims 19
Contact Information 19
FIGURES PAGE
Figure 1, AC600DBC interior 8
Figure 2, Lifting the workstation properly 9
Figure 3, Swell latch locations 10
Figure 4, Linecord connections 10
Figure 5, Control panel layout 11
Figure 6, Fluorescent bulb replacement 14
CONTENTS

3
Warranty registration must be completed online.
To activate warranty visit:
aircleansystems.com/warranty
AirClean® Systems is committed to providing our customers with quality equipment and service
after the sale. We request that you take a moment to ll out the warranty registration form at
aircleansystems.com/warranty so that we may ensure prompt and efcient service in the future.
AirClean® Systems provides a warranty on all parts and factory workmanship. The warranty includes
areas of defective material and workmanship, provided such defect results from normal and proper
use of the equipment.
The warranty for all AirClean® Systems products will expire one year from date of shipment from
AirClean® Systems, except for DrySafe™ and CyanoSafe™ product lines, which carry a two-year
warranty from date of shipment.
This limited warranty covers parts and labor, but not transportation and insurance charges. In the
event of a warranty claim, contact AirClean® Systems or the dealer who sold you the product. If
the cause is determined to be a manufacturing fault, the dealer or AirClean® Systems will repair or
replace all defective parts to restore the unit to operation. Under no circumstances shall AirClean®
Systems be liable for indirect, consequential, or special damages of any kind. This statement may be
altered by a specic published amendment. No individual has authorization to alter the provisions of
this warranty policy or its amendments. Lamps and lters are not covered by this warranty. Damage
due to accidental breakage is also not covered.
NOTE: Do not return any materials without authorization from AirClean® Systems.
Products returned without prior authorization will not be accepted. AirClean® Systems
and its dealers are not responsible for shipping damage. The recipient must le
claims directly with the freight carrier. If authorization has been received to return this
product, by accepting this approval, the user assumes all responsibility and liability
for biological and chemical decontamination and cleansing. AirClean® Systems reserves
the right to refuse delivery of any products which do not appear to have been properly
cleaned and/or decontaminated prior to return. Please see additional Shipping Claims
on Page 20.
IMPORTANT: Complete the warranty registration form at aircleansystems.com/warranty
WARRANTY

4
DECLARATION OF CONFORMITY
We: AirClean® Systems, Inc.
of: 3248 Lake Woodard Drive
Raleigh, North Carolina 27604
USA
declare that:
Product Name: Ductless PCR Workstation
Model Numbers: AC632DBC and AC648DBC
in accordance with the following Directives:
73/23/EEC The Low Voltage Directive as amended by 93/68/EEC
89/336/EEC EMC Directive as amended by 92/31/EEC
has been designed and manufactured to the following speci cations:
Safety: IEC 61010: 2001 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT
FOR MEASUREMENT
EMC: CISPR 11 Electromagnetic Disturbance Characteristics - Limits And
Methods of Measurement
IEC 61000-4-2 Electromagnetic Compatibility, ESD
IEC 61000-4-3 Electromagnetic Compatibility, Radiated Immunity
IEC 61000-4-4 Electromagnetic Compatibility, Fast Transient
IEC 61000-4-5 Electromagnetic Compatibility, Surge
IEC 61000-4-6 Electromagnetic Compatibility, Conducted Immunity
IEC 61000-4-8 Electromagnetic Compatibility, MM
IEC 61000-4-11 Electromagnetic Compatibility, Voltage Interruption
The CE marking has been af xed on the device according to article 10 of the EMC Directive 89/336/EEC.
I hereby declare that the equipment named above has been designed to comply with the relevant
sections of the above referenced speci cations. The unit complies with the essential requirements of the
directives.
Signed by:………………………………………
Name: M. Kevin McGough
Position: General Manager
Raleigh, North Carolina USA 15- Apr-2004

5
Alerts the user to the presence of dangerous voltages within the product’s enclosure that
maybe of sufcient magnitude to constitute a risk of electric shock to persons.
Alerts the user to the presence of important operating maintenance or service instructions.
Alerts the user to the possible presence of ultraviolet light.
Alerts the user that two persons are required for safe lifting of the object.
The presence of this symbol means that this equipment has been designed, tested and
certied as complying with the applicable Underwriter’s Laboratory (USA) regulations and
recommendations.
The presence of this symbol means that this equipment has been designed, tested and
certied as complying with all of the essential requirements applicable to European Union (CE)
regulations and recommendations.
This symbol alerts the user to the correct replacement fuses for the product.
Abbreviation Denition
PPE Personal Protective Equipment
OSHA Occupational Safety and Health Administration
ACGIH American Conference of Government Industrial Hygienists
TLV Threshold Limit Value
UV Ultraviolet
MSDS Material Safety Data Sheet
SYMBOLS THAT MAY APPEAR ON YOUR ENCLOSURE

6
Notices in this Manual
WARNING
Indicates a potentially hazardous situation, which if not avoided, could result in death or
serious injury.
CAUTION
Indicates a potentially hazardous situation, which if not avoided, may result in minor
or moderate injury. It may also be used to alert against unsafe practices or potential
equipment damage.
General Cautions
Always use a properly grounded line cord and receptacle.
Always replace fuses with those specied.
These instructions must be placed in an easily seen location.
DO NOT use this equipment for purposes other than nucleic acid preparation and amplication
of non-biological substances.
DO NOT use this system until it has been properly installed.
DO NOT operate this unit if the linecord appears damaged or frayed in any way.
DO NOT attempt to access non-user serviceable components of system.
DO NOT operate this unit if display is blank or hard to read. If display is hard to read, call
customer service.
DO NOT look directly at the UV light.
CAUTIONS AND PRECAUTIONS

7
TECHNICAL SPECIFICATIONS
SPECIFICATIONS AC632DBC AC648DBC
Physical Dimensions
Outside Dimensions 32”w x 30”h x 24”d 48”w x 32”h x 24”d
Inside Dimensions 31”w x 18”h x 23”d 47”w x 19”h x 23”d
Weight 100 lbs. 150 lbs.
Electrical
Voltage 110VAC 60 Hz or 230VAC 50 Hz 110VAC 60 Hz or 230VAC 50 Hz
Current 1.4A / .7A 2.8A /1.4A
Power Consumption 150W 300W
Mains Fluctuation ±10% ±10%
Fuses
Type 3A 250V, Slow Blow 5 X 20 6.3A 250V, Slow Blow 5 X 20
Requirements 1 (110V) / 2 (230V) 1 (110V) / 2 (230V)
Environmental
Usage Indoor Use Only Indoor Use Only
Altitude Up to 2000m Up to 2000m
Humidity 80% Max up to 31C Decreasing
Linearly to 50% at 40C
80% Max up to 31C Decreasing
Linearly to 50% at 40C
Installation Category II II
Pollution Degree 2 2
Construction
Top Material ABS ABS
Front Panel and Sides (3) Lexan™ Polycarbonate Lexan™ Polycarbonate
Base Material Structural Polypropylene Structural Polypropylene
Options
Cart w/ two 4” locking wheels 32”l x 24”w x 34”h 48”l x 24”w x 34”h

8
OVERVIEW
The AC600 Series DBC Workstation, with UVTect™ microprocessor-driven controller provides 254
nm short-wave UV light to effectively irradiate contaminating DNA and RNA within minutes. Short-
wave UV bulbs (254 nm) have a denable useful life of 1000 hours in your workstation. The UVTect™
Controller tracks UV bulb hours and alerts the user when to replace the UV bulb. The overlapping
sash design prevents operator exposure to shortwave UV energy.
1. UV light sterilizes pipette tips, tubes
and asks.
Figure 1, AC600DBC interior
WARNING
THIS WORKSTATION IS NOT DESIGNED FOR USE
WITH BIOLOGICAL SAMPLES.
Fluorescent
Light
UV Light
Pipette
Shelf
Slip Hatch
HOW THE AC600DBC WORKSTATION WORKS:

9
INSTALLATION INSTRUCTIONS
1) If ordered, assemble the mobile cart. Assembly instructions are included with the cart and
also in the OPTIONS section of this manual. (Page 20)
2) Designate the appropriate installation location. Make sure that the desired area is stable
enough to hold the workstation and that there is an appropriate AC wall receptacle near the
workstation. Do not place workstations near doors or windows.
3) With the help of a co-worker, lift the workstation out of the bottom tray of the box. Make sure
to lift from the bottom of the workstation. See gure 2.
CAUTION
DO NOT lift the workstation by the head assembly, the
sash, or any protruding wires.
4) Place the workstation in the desired location. Once in place, make sure that it is secure
and stable.
5) Visually inspect your workstation, checking for any damage that may have occurred in
shipping. Pay special attention to the sash hinges. If damage has occurred, call AirClean®
Systems immediately. DO NOT attempt to use workstation.
7) Make sure that the swell latches, located on the side lip of the head assembly, are in the
latched (down) position and that the head assembly is secure and properly seated. See
gure 3. (Page 10)
Figure 2, Lifting the workstation properly

10
Figure 3, Swell latch locations.
8) Ensure that the door switch cable on the right hand side of the head assembly is
secure. See gure 4.
9) Make sure that any exterior linecord connections are secure and seated properly. These
connections are located on the back of the workstation. See gure 4.
10) Locate the power entry module on the back of the workstation. Insert the female end of the
linecord into the power entry module and the male end into an appropriate electrical outlet.
See gure 4.
CAUTION
Only use approved accessories with the exterior
connectors.
Figure 4, Linecord Connections.
Power Entry
Module
Linecord
AC632DBC model AC648DBC model
Swell Latch Swell Latch
AC632DBC model AC648DBC model
Power Entry
Module
Linecord
Tabla de contenidos