AgSense Aqua Trac Pro Manual de usuario

2015-18 Aqua Trac Pro
Wiring Manual
Revised January 1, 2018

Items Covered In This Manual:
Page 1: Aqua Trac V1 and V2 Device Overview
Page 2: Connecting the Solar Panel
Page 3: Connecting the Watermark 200SS-V Sensor
Page 4: Connecting the Decagon 10HS or GS1 Sensor
Page 5: Connecting AquaCheck, Hydrascout, Wiseone.
Page 6: Connecting the Sentek Soil Moisture Probe
Page 7: Connecting the Decagon 5TM/5TE/MPS-2/GS3
Page 8: Connecting the Sentek Drill & Drop Probe
Page 9: Connecting the CS650 / CS655 Sensor
Page 10: Connecting the Acclima TDR315L Sensor
Page 11: Connecting the EnviroPro Probe
Page 12: Connecting the Greenshield Probe
Page 13: Connecting the Waterscout SM100 Sensor
Page 14: Connecting the AgSense Rain Bucket
Page 15: Connecting the AgSense Temperature Sensor
Page 16: Configuring the Aqua Trac on the web
Page 17-19: Aqua Trac V3 Updates and Info
Page 20: Connecting the Watermark 200SS Sensor
Page 21: Connecting the Watermark 200TS Sensor
Page 22: Connecting the ETape Level Sensor
Page 23: Connecting the AgSense Tank Monitor Sensor
Page 24: G2 200psi Pressure Transducer Wiring
Page 25: Pressure Switch or Float Switch Wiring
Page 26: Submersible Tank Monitor Sensors
Page 27: Configuring the Aqua Trac V3 on the web
Page 28-29: Specs and Warranty Information

General Overview of the Aqua Trac V1, and V2
Note 1: Once all sensors are connected and unit is ready to run, you must turn the ON/OFF
switch to the “ON” position, and contact your AgSense Dealer to finish setup and configuration
of this unit to read the sensors that you have installed.
Note 2: The pins marked SENSOR POWER as shown above should have a jumper connecting
the middle and 5v pins. This selects the power output to the sensors to be 5v. Do not move this
jumper for any reason unless these instructions inform you to do so. Page 1

Wiring the Solar Panel to the Aqua Trac Unit
Wiring the solar panel: Find the group of terminals (2) with the group label PWR
1. Connect the Black Wire (-) from the solar panel to the terminal marked GND as shown
above.
2. Connect the White or Red Wire (+) from the solar panel to the terminal marked SOLAR
as shown above.
Page 2

Wiring the Watermark 200SS-V sensor
to the Aqua Trac Unit
Wiring the Watermark 200SS-V sensor: You can have up to 4 Watermark sensors wired
into this unit. Starting with sensor 1, find the group of terminals (3) with the group label
WM 1
1. Connect the Red wire from the Watermark sensor to the terminal marked PWR as
shown above.
2. Connect the Black wire from the Watermark sensor to the terminal marked GND as
shown above.
3. Connect the White wire from the Watermark sensor to the terminal marked SIG as
shown above.
Note: Repeat steps 1-3 for any additional Watermark sensors (WM 2, 3, 4) Page 3

Wiring the Decagon 10HS or GS1 sensor
to the Aqua Trac Unit
Wiring the Decagon 10HS or GS1 sensor: You can have up to 4 Decagon 10HS/GS1
sensors wired into this unit. Starting with sensor 1, find the first group of terminals (3) as
shown above.
1. Connect the White wire from the Decagon 10HS/GS1 sensor to the terminal marked
PWR as shown above.
2. Connect the Bare wire from the Decagon 10HS/GS1 sensor to the terminal marked
GND as shown above.
3. Connect the Red wire from the Decagon 10HS/GS1 sensor to the terminal marked
SIG as shown above.
Note: Repeat steps 1-3 for any additional Decagon 10HS/GS1 sensors (WM 2, 3, 4)
Please follow the jumper settings on page 14 - set to Decagon 10HS for both the 10HS and GS1
sensors. Page 4

Wiring the AquaCheck, Hydrascout, or
Wiseone probe to the Aqua Trac Unit
Wiring the AquaCheck or Hydrascout probe: Find the group of terminals (3) with the group label
SDI
1. Connect the Blue wire from the AquaCheck probe to the terminal marked SIG as shown.
2. Connect the Yellow/Green stripe wire from the AquaCheck probe to the terminal marked
GND as shown above.
3. Connect the Brown wire from the AquaCheck probe to the terminal marked PWR as
shown above. Page 5

Wiring the Sentek soil moisture probe
to the Aqua Trac Unit
Wiring the Sentek probe: Find the group of terminals (3) with the group label SDI.
1. Connect the Blue wire from the Sentek probe to the terminal marked SIG as shown
above.
2. Connect the Yellow wire from the Sentek probe to the terminal marked GND as shown
above.
3. Connect the Red wire from the Sentek probe to the terminal marked PWR as shown
above.
4. The new Drill & Drop probe uses different wire colors: PWR = Red, GND = Green, and
SIG=White. Page 6

Wiring the Decagon 5TM, 5TE, MPS-2 or
GS3 Sensors to the Aqua Trac Unit
Wiring the Decagon 5TM, 5TE, MPS-2 or GS3 sensor:
Find the group of terminals (3) with the group label SDI.
1. Connect the Red wire from the Decagon Sensor to the terminal marked SIG as shown
above.
2. Connect the Bare wire from the Decagon Sensor to the terminal marked GND as shown
above.
3. Connect the White wire from the Decagon Sensor to the terminal marked PWR as shown
above. Page 7

Wiring the Sentek Drill & Drop Probe
to the Aqua Trac Unit
Wiring the Sentek probe: Find the group of terminals (3) with the group label SDI.
1. Connect the White wire from the Sentek probe to the terminal marked SIG as shown
above.
2. Connect the Green wire from the Sentek probe to the terminal marked GND as shown
above.
3. Connect the Red wire from the Sentek probe to the terminal marked PWR as shown
above.
Page 8