Agilent Technologies U1115A Manual de usuario

1
Preliminary Draft
Agilent U1115A Wireless Logging Display
Operating Instructions
The Agilent U1115A Wireless Logging display is designed to be used with the
Agilent U1200 Series handheld meters, Agilent U1117A IR-to-Bluetooth®1 Adapter,
Agilent U1177A IR-to-Bluetooth Adapter and mobile/software2applications to
provide you a total wireless remote connectivity solution.
With the U1115A, you can view readings from up to four handheld meters, which
means you can virtually be at multiple places simultaneously from an extended
distance of up to 100-metres (U1117A) within the line-of-sight.
Figure 1 Agilent wireless remote connectivity solution
1The Bluetooth®word mark and logos are registered trademark owned by Bluetooth SIG, Inc and any
use of such marks by Agilent is under license. Other trademark and trade names are those of their
respective owners.
2The Agilent U1115A only supports Agilent Handheld Meter Logger software for downloading logged data to
PC via Bluetooth connection.
Standard Shipped Items Checklist
The following items are included when you make a purchase:
• U1115AWirelessLoggingDisplay.
• Three1.5VAAbatteries.
• USBtomicroUSBcable(servesasexternalpoweronly).
• OperatingInstructions(thisbooklet).
Agilent U1200
Series Handheld
meters
U1115A wireless
logging display
Windows PC
Android devices
iOSdevices
U1117A IR-to-
Bluetooth adapter
U1177A IR-to-
Bluetooth adapter
Agilent PC Application Software
Agilent Handheld Meter Logger 2
Agilent Mobile Application
Agilent Mobile Meter
Agilent Mobile Logger

2
Preliminary Draft
Product Characteristics
Temperature Operatingcondition–20°Cto55°C
Storagecondition–40°Cto70°C
Relative Humidity (R.H) Upto95%at40°C(non-condensing)
Dimension (W x L x H) 92.0 mm × 107.9 mm × 33.5 mm
Weight 238 g with batteries , 170 g without batteries.
Battery Type •Lithium24–LF(ANSI)andFR03(IEC)
•Alkaline24A(ANSI/NEDA)andLR03(IEC)
•ZincChloride24D(ANSI/NEDA)andR03(IEC)
Battery Lifespan •Lithium batteries: 30 hours
•Alkaline batteries: 20 hours
Power Consumption Maximum1VAfor3AAbatteries
Maximum5V+10%,250mAforexternalpower
AutoPowerOffmode,currentconsumption3mA
Warranty Oneyear(Doesnotcovernormalwearandtearof
mechanical parts and batteries)
Bluetooth BluetoothSPPprole,Class1device
Compatibility AgilentHandheldMeter/Display:
•AgilentU1200SeriesHandheldMeters
•AgilentU1117AIR-to-Bluetooth Adapter
•AgilentU1177AIR-to-Bluetooth Adapter
Agilent Application Software:
•AgilentHandheldMeterLogger
HardwareDevice:
•WindowsPC(withBluetooth-enabled)
Regulatory
Complies with
IDAStandards
DB102425
The U1115A complies with the requirements of the
following product standards:
•EMCEN301489–1:V1.9.2
EN301489–17:V2.1.1
EN55022:2006+A1:2007
EN55024:1998+A1:2001+A2:2003
•RF(Bluetooth)EN300328V1.7.1(2006–10)
•RF(Health)EN62311:2008
•Safety EN60950–1:2006+A11:2009
+A1:2010+A12:2011

Preliminary Draft
3
Preliminary Draft
Regulatory •IndiaEquipmentTypeApproval(ETA)Certicate
No:1424/2011/WRLO
•COFETELCerticateNo:RCPAGU111-1066,
registered under Agilent Technologies Mexico S
deRLdeCV
“This telecommunication equipment conforms to the
NTCtechnicalrequirement”
Table 1 Connectivity distance (approximate) within the line-of-sight
U1177A U1117A U1115A
U1177A – – 10 m
U1117A – – 100 m
U1115A 10 m 100 m –
Other Class 1 devices 10 m 100 m 100 m
Other Class 2 devices 10 m 10 m 10 m
•FCC:ThedevicecontainsFCCID:QOQWT11IA
•CanadaIC:ThedevicecontainstransmitterIC:5123A–BGTWT11IA
•TocomplywithFCCandIndustryCanadaRFradiationexposurelimitsfor
general population, the antenna(s) used for this transmitter must be
installed such that a minimum separation distance of 20cm is maintained
between the radiator (antenna) and all persons at all times and must not be
colocated or operating in conjunction with any other antenna or transmitter.
•“La operación de este equipo está sujeta a las siguientes dos condiciones:
(1) es posible que este equipo o dispositivo no cause interferencia
perjudicial y (2) este equipo o dispositivo debe aceptar cualquier
interferencia,incluyendolaquepuedacausarsuoperaciónnodeseada.”
•TheradiomodulecertiedbyJapaneseRadioLawisintegratedinside.
•NCCWarningStatement:
•Article12
Withoutpermission,anycompany,rmorusershallnotalterthe
frequency, increase the power, or change the characteristics and
functionsoftheoriginaldesignofthecertiedlowerpowerfrequency
electric machinery.
•Article14
The application of low power frequency electric machineries shall not
affect the navigation safety nor interfere a legal communication, if an
interference is found, the service will be suspended until improvement is
made and the interference no longer exists.

4
Preliminary Draft
Front View
Sample annunciator Time indicator
Batteryindicator
F3key
Functionkeys
Logger keyNavigationkeys
Meter key
Figure 2FrontviewoftheU1115AWirelessLoggingDisplay
Side View
Slide power switch
Stand
Externalpowerport
(microUSBport)
Figure 3SideviewoftheU1115AWirelessLoggingDisplay(standingposition)
Save
Logger
isplay
HOLD MODE CONNECT SETTINGS
01:01
F1 F2 F3 F4
Meter
Agi l ent U111 5A
Clas s 1
1 0 0 m

Preliminary Draft
5
Preliminary Draft
Back View
Slide power switch
Stand
Batterycover
with attached
magnet
Figure 4BackviewoftheU1115AWirelessLoggingDisplay
Turning On the U1115A
To turn on the U1115A , set the slide power switch to On. (gure 4)
•OnceaconnectedIR-to-Bluetooth Adapter is turned off, below
scenarios will occur :
1 The Not Connected annunciator will appear on the display.
2 Subsequently, the annunciator will only appear after 15s-20s.
Supplying External Power to the U1115A
1PlugthemicroUSBheadtothemicroUSBportonthesideoftheU1115A.
(gure 3)
2PlugtheUSBconnectortoaUSBpowersourcetosupplyanexternalpowertothe
U1115A.
•ThemicroUSBportontheU1115Aservesasanexternalpowerport
and not for data transfer or battery charger.
•The batteries are safe to remain inside the U1115A while it is being
powered up by an external power.

6
Preliminary Draft
Install and Replace the Batteries
Make sure you turn off the U1115A before installing or replacing the
batteries.
To avoid the U1115A being damaged from battery leakage:
Always remove dead batteries immediately.•
Always remove the batteries and store them separately if the•
U1115A is not going to be used for a long period of time.
Remove the battery protective sheet
beforeusingforthersttime.
1 2
3 4

Preliminary Draft
7
Preliminary Draft
Connecting to devices
EnsurethattheLinkLEDatthebackoftheIR-to-Bluetooth adapter
is blinking before establishing a connection.
Power cycle if necessary.
Press to enter the Connection Manager. Typical Connection Manager display.
Press to add devices. Press to scan for devices.
Typical Available Devices display.
Press to navigate to
desired device.
F3
CONNECT
Back
A> Add Device
B> Add Device
C> Add Device
D> Add Device
Bluetooth Enter
Connection Manager
01:01
F4
Enter Scan
57AE5B
1
Scan Select
U1177A-2718DE
2
Available
1 2
3 4
5 6
F3

8
Preliminary Draft
Connecting to devices (continued)
Press to select the desired device. Typical Connection display.
Press to navigate to desired
function.
Select• Connect to make a connection.
Select• Cancel to cancel a connection.
Select• Pairing PIN : 1234 to change
PINnumber.EnsurethattheU1115A
and the IR-to-Bluetooth adapter(s)
havematchingPINnumber(s).
Select• Connect at Startup to set
thedevicetoconnectonstartup.By
selecting this option, it will determine
the number of views as shown in
Table 1.
7 8
9 10
Select
F4
Connectionmanagercanaddupto4devicesatanyonetime.
Meter view is automatically selected based on the table below :
Table 2 MeterViewselection
Connected
devices Connect at Startup Meter View
1 1-meter view
2 2-meter view
3or4 4-meterview

Preliminary Draft
9
Preliminary Draft
Meter Views
Typical screen display when no meter is
connected to the U1115A.
Typical screen display when one meter
is connected to the U1115A.
Typical screen display when two meters
are connected to the U1115A.
Typical screen display when three
or four meters are connected to the
U1115A.
The U1115A screen display will show ----- when below scenarios occur :
1Nometerisconnected.
2 Meter(s) function/mode is not supported by the U1115A.
3 When the user changes the meter’s function. Typical wait time is 5s.
01:01
HOLD MODE CONNECT SETTINGS
-----
A> U1117A-57AE5B Not Connected
A> U1273A-MY51430008U1117A-57AE5B
A> U1273A-MY51430008
B> U1177A-2718DE U1272A-MY52800017
U1117A-57AE5B
U1273A-MY51430008
A> U1272A-MY52800017
B> U1177A-2718DE
U1252B-MY51040033
C> U1117A-2391BA Not Connected
U1117A-57AE5B
1 2
3 4

10
Preliminary Draft
Selecting Measurement Mode
Typical Meter view display.
Press to navigate
to the desired
meter.
Press to enter
Mode menu.
Typical Mode display.
The active window will be highlighted.
Press to select
desired mode. In
thisexample,ACV
is selected.
Press to exit Mode
menu.
U1273A-MY51430008 U1272A-MY52800017
B> U1177A-2718DE
U1252B-MY51040033
C> U1117A-2391BA Not Connected
A> U1117A-57AE5B
MODEHOLD CONNECT SETTINGS
123
4
MODE
F2
Vac
F2
U1273A-MY51430008 U1272A-MY52800017
B> U1177A-2718DE
U1252B-MY51040033
C> U1117A-2391BA Not Connected
A> U1117A-57AE5B
Vac Vdc Vacdc
56
Meter
Este manual sirve para los siguientes modelos
2
Tabla de contenidos