Instruction manual condensation dryer AD 530 / AD 630 / AD 630F AERIAL GmbH
from serie July 2003 page 8
5 The safeguard of the
building is too weak.
The building safeguard must be
checked and/or transposed.
The automatic circuit breaker
of the building disturbs the
voltage supply to the device.
6 A malfunction in the
electrical circuit of the dryer
is available.
The voltage supply of the dryer
must be disturbed. (Pull power
plug!) The defect must be
eliminated by an expert.
The fan of the dryer is out of
operation
7 The dryer is in the defrost
mode
The fan starts again after some
minutes. If it does not start again,
the defect must be eliminated by
an expert.
8 The filter holder is not
correctly inserted
The filter holder must be inserted
correctly
It occurs an unusual, strong
noise formation
9 One or several case screws
are not tightened correctly.
The slack case screws must be
tightened correctly.
10 The dryer is switched off Switch on the unit at on/off-switch
11 The humidity adjusted at the
hygrostat is achieved.
The dryer turns on automatically
after exceeding the adjusted
humidity again.
12 The water tank is full The water tank must be emptied
and put into the device back.
The complete dryer is out of
operation
13
There is defective at the
device
The defect must be eliminated by
an expert.
That dehumidifier is frozen at
the evaporator very strong.
You can see an ice block.
14
15
The room temperature is or
was lower than +3°C for a
time.
There is a defective at the
automatic defrost system
You might put the dryer into a
room with at least +10°C and wait
until the entire has thawed ice.
Turn on after this the device again
and it might let about 3 hours run.
If a new glacial block should form
itself, contact your supplier.
Otherwise make sure that the
device is only used in rooms, in
which +3°C being at least.
Ice build-up is also possible after
too immediate switch-on after
storage in colder conditions.
The defect must be eliminated by
an expert.