AEMC SL261 Manual de usuario

AC/DC CURRENT
OSCILLOSCOPE PROBE
SL261
ENGLISH User Manual
ZERO
100 mV/A
10 mV/A
OFF
I
Shop for Data Logging products online at: www.DataLoggerStore.ca 1.800.561.8187

Statement of Compliance
Chauvin Arnoux®, Inc. d.b.a. AEMC®Instruments
certifies that this instrument has been calibrated
using standards and instruments traceable to
international standards.
We guarantee that at the time of shipping your
instrument has met its published specifications.
An NIST traceable certificate may be
requested at the time of purchase, or obtained
by returning the instrument to our repair and
calibration facility, for a nominal charge.
The recommended calibration interval for this
instrument is 12 months and begins on the date of
receipt by the customer.
Serial #: ________________________________
Catalog #: 1201.51
Model #: SL261
Please fill in the appropriate date as indicated:
Date Received: _________________________________
Date Calibration Due: _______________________
Shop for Data Logging products online at: www.DataLoggerStore.ca 1.800.561.8187

Table of Contents
1. INTRODUCTION............................................................................... 2
1.1 International Electrical Symbols................................................3
1.2 DenitionofMeasurementCategories .....................................3
1.3 ReceivingYourShipment..........................................................3
1.4 OrderingInformation.................................................................4
1.4.1 AccessoriesandReplacementParts............................4
2. PRODUCT FEATURES ...................................................................... 5
2.1 Description................................................................................5
2.2 Compatibility .............................................................................5
2.3 Features....................................................................................6
3. SPECIFICATIONS............................................................................. 7
3.1 ElectricalSpecications ............................................................7
3.2 MechanicalSpecications ........................................................8
3.3 EnvironmentalSpecications....................................................9
3.4 SafetySpecications ................................................................9
3.5 TypicalResponseCurves .......................................................10
4. OPERATION .................................................................................. 12
4.1 ZeroAdjustment......................................................................12
4.2 CurrentMeasurement.............................................................12
4.3 Battery Indication (Green LED)...............................................13
4.4 Peak Overload (OL) Indication (Red LED) .............................13
5. MAINTENANCE ............................................................................. 14
5.1 Maintenance ...........................................................................14
5.2 Cleaning..................................................................................14
5.3 ReplacingtheBatteries...........................................................15
Limited Warranty ...................................................................................17
WarrantyRepairs...................................................................................17
Shop for Data Logging products online at: www.DataLoggerStore.ca 1.800.561.8187

2
AC/DC Current Oscilloscope Probe Model SL261
CHAPTER 1
INTRODUCTION
WARNING
The safety warnings are provided to ensure the safety of
personnel and proper operation of the instrument. Read the
instruction completely.
• Usecautiononanycircuit:potentiallyhighvoltagesandcurrents
maybepresentandmayposeashockhazard.
• Donotusetheprobeifdamaged.Alwaysconnectthecurrent
probetothemeasuringdevicebeforeitisconnectedaroundthe
conductor
• Donotuseonnoninsulatedconductorwithapotentialtoground
greaterthan600VCATIIIpollution2.Useextremecautionwhen
clampingaroundbareconductorsorbusbars.
• Beforeeachuse,inspecttheprobe;lookforcracksinhousingor
outputcableinsulation.
• Donotuseclampinwetenvironmentorinlocationsthathazard-
ousgasesexist.
• Donotusetheprobeanywherebeyondthetactilebarrier.
Shop for Data Logging products online at: www.DataLoggerStore.ca 1.800.561.8187

AC/DC Current Oscilloscope Probe Model SL261
3
1.1 International Electrical Symbols
This symbol signifies that the instrument is protected by double or rein-
forced insulation.
This symbol on the instrument indicates a WARNING and that the operator
must refer to the user manual for instructions before operating the
instrument. In this manual, the symbol preceding instructions indicates that
if the instructions are not followed, bodily injury, installation/sample and
product damage may result.
Risk of electric shock. The voltage at the parts marked with this symbol may
be dangerous.
This symbol refers to a type A current sensor. This symbol signifies that
application around and removal from HAZARDOUS LIVE conductors is per-
mitted.
Probe fitted with an electronic output limiter providing protection against
voltage surges caused by the accidental opening of the probe secondary
circuit to 30V max. peak.
In conformity with WEEE 2002/96/EC.
1.2 Definition of Measurement Categories
CAT I: Formeasurementsoncircuits not directlyconnectedtotheAC
supply wall outlet such as protected secondaries, signal level,
andlimitedenergycircuits.
CAT II: For measurements performed on circuits directly connected to
the electrical distribution system. Examples are measurements
onhouseholdappliancesorportabletools.
CAT III: For measurements performed in the building installation at
the distribution level such as on hardwired equipment in xed
installationandcircuitbreakers.
CAT IV: For measurements performed at the primary electrical supply
(<1000V) such as on primary overcurrent protection devices,
ripplecontrolunits,ormeters.
1.3 Receiving Your Shipment
Uponreceivingyourshipment,makesurethatthecontentsareconsistent
with the packing list. Notify your distributor of any missing items. If the
equipmentappearstobedamaged,leaclaimimmediatelywiththecar-
rierandnotifyyourdistributoratonce,givingadetaileddescriptionofany
damage.Savethedamagedpackingcontainertosubstantiateyourclaim.
Shop for Data Logging products online at: www.DataLoggerStore.ca 1.800.561.8187

4
AC/DC Current Oscilloscope Probe Model SL261
1.4 Ordering Information
AC/DCCurrentProbeModelSL261
(10A-100mV/A,100A-10mV/A,BNC).................................. Cat. #1201.51
Includes a user manual and a product warranty and registration card.
1.4.1 Accessories and Replacement Parts
Adapter-BNCAdapterforusewithAC/DCCurrentProbe
ModelSL261&Meters8220&8335................................... Cat. #2140.40
Shop for Data Logging products online at: www.DataLoggerStore.ca 1.800.561.8187

AC/DC Current Oscilloscope Probe Model SL261
5
CHAPTER 2
PRODUCT FEATURES
2.1 Description
The SL261 AC/DC Current Oscilloscope Probe expands oscilloscope
applicationsinindustrial,automotiveorpowerenvironments,andisideal
for analysis and measurement of distorted current waveforms and har-
monics.Theprobepermitsaccuratedisplayandmeasurementofcurrents
from100mAto100Arms,DCto100kHzwithoutbreakingintothecircuit.
TheprobeusesHalleffecttechnologytomeasureACandDCsignals.The
probeconnectsdirectlytoanoscilloscopethrougha2metercoaxialcable
withaninsulatedBNC.
2.2 Compatibility
TheModelSL261iscompatiblewithanyanalogordigitaloscilloscopeor
othervoltage-measuringinstrumentwhichhasthefollowingfeatures:
• BNCinputconnector
• Rangecapableofdisplaying0.2to0.5Vperdivision
• Minimuminputimpedanceof1MΩ
Shop for Data Logging products online at: www.DataLoggerStore.ca 1.800.561.8187

6
AC/DC Current Oscilloscope Probe Model SL261
2.3 Features
ZERO
OFF
I
Battery
Compartment
Screw
Range Selection Switch
Power Indication LED
Zero Adjust Knob
Current Flow for DC Measurements
or Supply to Load for AC Measurements
Battery
Compartment Cover
Ø = 0.46"
(11.8 mm)
Peak Overload
Indication LED
Keep hands below
this point
100 mV/A
10 mV/A
WARNING: Always keep hand on the handle part of the probe.
Shop for Data Logging products online at: www.DataLoggerStore.ca 1.800.561.8187

AC/DC Current Oscilloscope Probe Model SL261
7
CHAPTER 3
SPECIFICATIONS
3.1 Electrical Specifications
*Referenceconditions:23°C±5°C,20to75%RH,DCto1kHz,probezeroed,1minute
warmup,batteriesat9V±0.1V,externalmagneticeld<40A/m,noDCcomponent,no
externalcurrentcarryingconductor,1MΩ/100pFload,conductorcenteredinjaw.
Current Range:
100mV/A:100mAto10Apeak
10mV/A:1to100Apeak
Output Signal:1000mVpeakmax
AC Current Accuracy:
Aftercalibrationandforoneyear
(zeroprobebeforemakingmeasurement)
Range Accuracy Phase Shift
100mV/A
(50mAto10Apeak) 3%ofreading±50mA <1.5°fromDCto65Hz
10mV/A
(500mAto40Apeak) 4%ofreading±50mA
<1°fromDCto65Hz
10mV/A
(40Ato100Apeak) 15%maxat100A
Frequency Range: DCto100kHz(-3dBwithcurrentderating)
Noise:
Range10mV/A:480µV
Range100mV/A:3mV
Slew Rate:
Range10mV/A:20mV/µs
Range100mV/A:0.3V/µs
Load Impedance: >1MΩ/100pF
Insertion Impedance (50/60 Hz): 100mV/A:3µs
10mV/A:0.01Ω
Shop for Data Logging products online at: www.DataLoggerStore.ca 1.800.561.8187

8
AC/DC Current Oscilloscope Probe Model SL261
Rise or Fall Time:Range100mV/A:3µs
Range10mV/A:4µs
Working Voltage: 600Vrmsmax
Common Mode Voltage: 600Vrmsmax
Inuence of Adjacent Conductor: < 0.2mA/A AC
Inuence of Conductor Position in Jaw: 0.5%ofreadingatkHz
Battery: 9Valkaline(NEDA1604A,IEC6LR61)
Low Battery: GreenLEDwhen≥6.5V
Overload Indication:
RedLEDindicatesinputgreaterthantheselectedrange
Typical Consumption: 8.6mA
Battery Life: 55hourstypical
3.2 Mechanical Specifications
Zero Adjustment: 20turnpotentiometer
Maximum Cable Diameter: 0.46" (11.8 mm)
Case Protection: IP20perIEC529
Drop Test:
1.0mon38mmofoakonconcrete;testaccordingtoIEC1010
Mechanical Shock: 100G;testperIEC68-2-27
Vibration:
TestperIEC68-2-6,frequencyrange10Hzto55Hz,amplitude0.15mm
Handle: Lexan®920A,UL94V2
Dimensions: 9.09x1.42x2.64"(231x36x67mm)
Weight: 11.6oz(330g)withbattery
Color: Lightgray
Output Lead: InsulatedcoaxialcablewithinsulatedBNCconnector
Cable Length: 6.5foot(2m)
Shop for Data Logging products online at: www.DataLoggerStore.ca 1.800.561.8187
Otros manuales para SL261
4
Tabla de contenidos
Manuales populares de Equipo de laboratorio de otras marcas

Agilent Technologies
Agilent Technologies 5800 ICP-OES Manual de usuario

Endress+Hauser
Endress+Hauser Cleanfit CPA875 Manual de usuario

NI
NI PXI-5422 Manual

Collomix
Collomix Aqix Manual de usuario

SPEX SamplePrep
SPEX SamplePrep 6875 Freezer/Mill Series Manual de usuario

Ocean Insight
Ocean Insight FLAME-NIR+ Manual de usuario