ADDC SR-20RM Manual de usuario

SR20-RM
USER GUIDE
PLUG INTO THE FUTURE OF TECHNOLOGY

2
Revision History
Revision Notes
V2.3 Revision 2.3 was published in
November of 2022.

3
Table of Contents
Section 1 Receiving Your SR20-RM 5
Section 1.1 What's in the Box? 5
Section 2 SR20-RM Preparation 6
Section 2.1 Preparing For Your SR20-RM 6
Section 2.2 Installing Your SR20-RM into a Rack 7
Section 2.3 Installing Your BioDigitalPC®s 8
Section 2.4 SR20-RM Power Supplies 10
Section 2.5 Networking Your SR20-RM 11
Section 2.6 Powering On Your SR20-RM 12
Section 3 SR20-RM Overview 13
Section 3.1 SR-10 Modules 14
Section 3.2 Rear Panel 15
Section 3.3 Front Panel 16
Section 4 ROMWare Soware 17
Section 4.1 Login 17
Section 4.2 Main Screen Overview 18
Section 4.3 AC Power Monitoring 19
Section 4.4 DC Power Control & Monitoring 20
Section 4.5 BioDigitalPC Power Monitoring & Control 21-23
Section 4.6 SR-10 Switch Serial Interface 24
Appendix A Testing Your SR20-RM 25
Appendix B A Successful SR20-RM Component Test 26

4
Notes, Important Information & Warnings
is manual details installation of the chasis, the components inside of the chassis, and notable features of the SR20-RM
server solution.
Installations will be supported by ADDC. Unless otherwise specied, all instructions provided in this manual will assume
that a user is a trained technician.
How to Read this Document
You will see this icon throughout the manual intended to point out warnings, important information, and briey
explain any new terminology.

5
Equipment (Not Included)
• Laptop or Testing Network
• 5/32" Allen Key (Optional)
Equipment (Included)
• SR20-RM Chassis
• SR20-RM Top Cover [Comes Assembled]
• BioDigitalPC®Server Cards [Check Invoice
for Quantity]
• 2 AC/DC Power Supplies
• 4 10Gbps SFP+ Cables
• 2 AC Power Cords
• 2 Rack Slides
Section 1.1 - What's in the Box?
10Gbps SFP+ Cables
SR20-RM Chassis
SR20-RM Top Cover
Rack Slides
AC/DC Power Supplies
AC Power Cords
Section 1.0 - Recieving Your SR20-RM

6
When installing the SR20-RM into a rack, the selected location should meet environmental standards as described
below.
Rack Space and Airow Considerations
To allow for adequate airow, technicians should observe the following space and airow requirements when
deciding where to install a rack.
• Leave a minimum clearance of 12in (30.48cm) in front of the rack.
• Leave a minimum clearance of 8in (20.32cm) behind the rack.
Temperature Considerations
Your SR20-RM is designed to operate at room temperature with its self-contained cooling.
Power Considerations
When properly congured and installed the SR20-RM can draw up to 700 Watts (400 Watts on average) depending
on the number, load, and version of the BioDigitalPC®s used.
To prevent improper cooling of equipment, do not block the fans.
Section 2.1 - Preparing For Your SR20-RM
If using the dual feed redundant power solution (See Section 2.6.2), each power source must be capable of
supporting a maximum draw of 650 Watts.
Section 2 - SR20-RM Preparation

7
Section 2.2 - Installing Your SR20-RM into a Rack
A. B.
e chassis package includes two rail assemblies in the rack mounting kit. Each assembly consists of two sections: an
inner xed chassis rail that secures directly to the server chassis and an outer xed rack rail that secures directly to
the rack itself.
Stability hazard. e rack stabilizing mechanism must be in place, or the rack must be bolted to the
oor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip over and cause
severe injury to the technicians and damage to the device.
is section provides information on installing the SR20-RM chassis into a rack unit with the quick-release rails
provided.
Mount Rack Slides on the SR20-RM
Inner and outer chassis rails are shipped together, before continuing please seperate outer rail from inner rail.
Attached the inner rails to the server rack .
Once done, slide the SR20-RM onto the
server rack.

8
Section 2.3 - Installing Your BioDigitalPC®s
BioDigitalPC®s are hot-pluggable, meaning technicians do not need to remove power to begin adding or removing
them.
Section 2.3.1 - Removing the SR20-RM Top Cover:
In order to add or remove BioDigitalPC®s the SR20-RM chassis can be pulled out of the rack, or the SR20-RM's Top
Cover needs to be removed temporarily.
SR20-RM system can be running while installing new server cards.
Only trained technicians are authorized to work beneath the SR20-RM System Cover and access any of the
components inside the system.
Section 2.3.2 - Installing a BioDigitalPC®
Step 3: Insert Card with
"Arnouse Digital Devices
Corp." facing upwards and
the connector of the card
is facing towards the latch.
When inserting the card place
between the two horizontal
metal bars, ensuring the
card is going to be aligned
properly.
Step 4: Once the card is in
between the two horizonal
bars, locate the small locking
tab and push it in towards
the card. e card should
now be locked into place.
Fully inserted card
Step 1: Make
sure the latch is
perpendicular to
the system cover.
Step 2: Make sure locking
tab is unlocked.
small locking
tab
latch

9
Step 1: Find the
locking tab located to
the right of the card
slot.
Unlock the locking
tab.
Section 2.3.4 - Replacing the SR20-RM Top Cover
Section 2.3.3 - Removing a BioDigitalPC®
Section 2.3 - Installing Your BioDigitalPC®s
Once complete, a technician should
replace the SR20-RM Top Cover.
Step 3: Li to remove the card from
its slot
Step 2: Pull the ejection
bar forward towards
you, you should feel
the card pop out of the
connector.

10
Section 2.4 - Installing Your SR20-RM Power Supplies
Section 2.4.1 - Remove an SR20-RM Power Supply
1. Push SR20-RM Power Supply locking tab to the le.
2.While holding the locking tab, pull the SR20-RM Power Supply
handle and remove.
Section 2.4.2 - Install an SR20-RM Power Supply
1. Locate an empty SR20-RM Power Supply bay
2. Push the SR20-RM Power Supply straight into the SR20-RM
Chassis
3. Connect your AC Power Cord into the replacement SR20-RM
Power Supply
4. You should see the "OK" LED illuminated green.
Handle
Tab
Correct orientation pictured, inserting power supplies upside down may damage the system.
e SR20-RM requires one power supply
for the system to operate optimally. Each
power supply powers 10 PC cards.
To ensure redundancy see the power supply
schemas in Section 2.6.
Remove and replace only one power supply
at a time in a system that is to always remain
powered on.
Aer installing a new power supply allow
several seconds for the system to recognize
the new component. e power supply OK
status indicator will turn green to signify that
the power supply is functioning properly.
Otros manuales para SR-20RM
1
Tabla de contenidos
Otros manuales de Almacenamiento de ADDC
Manuales populares de Almacenamiento de otras marcas

Spectra Logic
Spectra Logic T-Series Spectra T50e Manual de usuario

Panasonic
Panasonic LKM-F931-1 Manual de usuario

Tabernus
Tabernus Enterprise Erase E2400 Manual de usuario

Rocstor
Rocstor COMMANDER 3F series Manual de usuario

HP
HP P9000 Manual de usuario

Western Digital
Western Digital Ultrastar Data60 Manual de usuario