Strike I and II UV-LED Water Disinfection Module
PRODUCT MANUAL
Advanced UV-LED Water Purification | acuvatech.com Page 7
Product Information
Strike Electrical Characteristics Cont’d
Net Condition Value Unit
VCC
Max. Input Voltage 30 V
Min. Input Voltage 11 V
Max. Current Draw = 0.5 A
Min. Current Draw = 0.25 A
LED Health
Indicator (IND)1
Normal Operation Output Voltage VCC V
Fault Operation Output Voltage 0.150 V
Maximum Normal Operation Current 3.5 mA
Maximum Fault Current -20 mA
Enable (EN)2Maximum Input Voltage for Operation 5.0 V
Minimum Input Voltage for Operation 2.5 V
: Electrical characteristics of Strike module
1IND net contains an internal 5.1kΩ pullup resistor
1VCC will be present on the LED Health Indicator pin when the module is enabled and LED is healthy.
LED Health Indicator will be 0.15V in all other conditions.
2EN net contains an internal 510Ω pulldown resistor
WARNING
Do not exceed maximum electrical ratings for any electrical IO position.
Strike UV-LED electronics always require proper protections respecting
these ratings. See section
for details on proper electrical integration.
Absolute Maximum Rating
Input Voltage 30V
Reverse Input Voltage 0.3V
Enable Pin Voltage 5.5V
Water Temperature 45oC
Ambient Temperature 55oC
Water Flow Rate 4.0 LPM
Electrostatic Discharge (ESD) 2.0 kV (HBM)
: Absolute maximum electrical ratings