ActronAir WC-02 Instrucciones de funcionamiento

IMPORTANT NOTE:
Please read this manual carefully before installing or operating your wired remote controller. Make sure to save this manual
for future reference.
Copy/
Follow me
Back/TurboConrmDay o/DelTimerSwing
OWNER’S MANUAL
INSTALLATION &
Universal Wired Remote Controller
Model Number:
WC-02
That’s better. That’s Actron.

1. Safety Precaution..................................................................................... 3
2. Installation Components......................................................................... 4
3. Installation Method................................................................................. 5
4. Specification............................................................................................ 10
5. Wired Controller Features and Functions................................................ 11
6. Wired Controller Display......................................................................... 12
7. Wired Controller Buttons........................................................................ 13
8. Preparatory Operation............................................................................ 14
9. Operation................................................................................................ 15
10. Timer Functions .................................................................................... 20
11. Weekly Timer........................................................................................... 23
12. Fault Alarm Handing ............................................................................... 30
Table of Contents
Installation and Owner’s Manual
Page 2

Page 3
1. Safety Precautions Wired Remote Controller
WARNING
• Carefully read the Safety Precautions before installation. Adhere to this installation manual.
• Only trained and qualified HVAC technicians should install, repair and service this air conditioning unit, strictly follow the
installation instructions set forth in this manual. Improper installation may result in electrical shock, short circuit,
leaks, fire or other damage to the equipment and personal property.
• Reinstallation must be performed by a qualified service technician.
WARNINGS FOR PRODUCT USE
• DO NOT install the unit in a place vulnerable to leakage of flammable gases. If flammable gases leak or linger around the
wired controller, fire may occur.
• CODES, REGULATIONS, AND STANDARDS
The installer/contractor assumes responsibility to ensure that the installation complies with the releveant council,
state/federal codes, regulations and building code standards. All electrical wiring must be in accordance with current
electrical authority regulations and all wiring connections to be as per the electrical diagram/s provided with the unit.
This manual gives detailed description of the precautions
that should be brought to your attention during operation.
To ensure the correct service of the wired controller
read this manual carefully before using the unit.
Keep this manual after reading for future reference.
This manual is a controlled document which contains confidential and proprietary information.
Distribution, modification, copying and/or reproduction are prohibited without written consent from ActronAir
Product design and specifications are subject to change without prior notice for product improvement.
Read Safety Precautions Before Installation
Thank you for purchasing this air conditioner. This manual will provide you with information on how to operate, maintain,
and troubleshoot your air conditioner. Following the instructions will ensure the proper function and extended lifespan of
your unit.
Please pay attention to the following signs:
WARNING
Failure to observe a warning may result in death or serious injury. The
appliance must be installed in accordance with national regulations.
Failure to observe a caution may result in injury or equipment damage.
MUST BE INSTALLED BY A
LICENSED ELECTRICIAN
D I Y
DIY
DIY
ALL ELECTRICAL WORK
MUST BE PERFORMED
BY A LICENSED ELECTRICIAN
FOR COMPLIANCE WITH
QUEENSLAND ELECTRICAL SAFETY
REGULATIONS 2002
This refers to electrical works only

Page 4
2. Installation Components Wired Remote Controller
Precaution for the installation of the wired controller
1. This manual provides the installation method for the wired controller. Please refer to the wiring diagram in this
installation manual to wire the wired controller with the indoor unit.
2. The wired controller uses extra-low voltage (ELV) only. DO NOT connect to low voltage 230VAC circuits or wiring as
damage to wired controller will result. Maintain correct separations between ELV wiring and other 230VAC mains
wiring.
3. The shielded wire of the wired controller must be properly grounded, see wiring diagram.
4. Upon finalising the wired controller connection, do not use an ohmmegger test to check the insulation.
No. Name Qty Remarks
1Wired controller 1 -
2Installation and owner’s manual 1 -
3Screws 3 M4X20 (for mounting on the wall)
4Wall plugs 3 For mounting on the wall
5Screws 2 M4X25 (for mounting on switch box)
6Plastic screw bars 2 For fixing on switch box
7Battery 1
8connecting cables 2

Page 5
1. Wired remote controller dimensions
3. Installation Method Wired Remote Controller
Fig 3.1

Page 6
3. Wiring Connection For Wall Splits
2. Wiring Connection Diagram for Cassettes & Ducted
1. Connect wired controller to indoor unit mainboard using the connecting cables included. Connect the adaptor cable
(smaller cable) first to the indoor main board. Then connect the wired controller using the longer connecting cable.
Fig 3.2
1. Open the front panel , identify the multi function box (See Fig.3.3.1).
2. Cut the terminal of the longer connection cable (See Fig 3.3.2).
3. Connect the four wires to each of the pins in the multi function board as follows:
The red wire on wire controller connect to 12/5V pin on multi function board; black wire to E pin; yellow wire to Y pin;
brown wire to X pin. (See Fig.3.3.1).
Fig 3.3.2
Fig 3.3.1 When connecting to
4-core wired controller:
12V = Red
E = Black
Y = Yellow
X = Brown
3. Installation Method Wired Remote Controller
Wired Controller Multi-function board
Connecting cable
Wired Controller Insert of the mainboard CN40
Indoor Unit
Mainboard
Connecting cable
4-core shielded cable
CN40
adaptor cable

Page 7
4. Wire controller - Removing the upper part
3. Installation Method Wired Remote Controller
Insert a flat screwdriver into the slots in the lower part of the wire controller (2 places).
Remove the upper part of the wire controller (Fig.3.4)
Fig 3.4
NOTE
The PCB is mounted in the upper part of the wired
controller. Be careful not to damage the board with the
screwdriver.
NOTE
Place on a flat surface. Be careful not to distort the wire
controller’s back plate by over−tightening the mounting
screws.
5. Fasten the wire controller back plate
For surface mounting, fasten the back plate on the wall with the 3 screws (M4x20) and plugs. (Fig.3.5)
Fig 3.5

Page 8
Place the battery in the unit and ensure the positive side of the battery is in accordance with the polarity markings.
(See Fig.3.7)
Set the correct time before operating. Batteries in the wired controller can maintain the correct time during a power
failure. When the power is restored and the displayed time is not correct, replace the battery.
There are three methods:
1. from the rear;
2. from the bottom;
3. from the top;
4. Notch the part for the wiring to pass through with a nipper tool.
6. Battery installation
3. Installation Method Wired Remote Controller
Fig 3.7
Fig 3.8
7. Wiring the indoor unit
31
2
NOTE
DO NOT allow water to enter the remote control.
Use a water loop and silastic to seal the wires.
Silastic
Silastic
Silastic
Loop
Loop
Loop

Page 9
3. Installation Method Wired Remote Controller
Fig 3.9
8. Reattach the wire controller’s upper part
While adjusting and mounting the upper case, avoid clamping the wiring during installation. (Fig 3.9)
IMPORTANT: All the pictures in this manual are for
illustration purposes only.
Your wire controller may differ slightly.

Page 10
Wiring Specifications
4. Specification Wired Remote Controller
Input Voltage DC 12V
Ambient Temperature 5ºC~43ºC
Ambient Humidity RH40%~RH90%
Wiring Type Size Total Length
Shielded PVC or cable
0.75mm2 20m
1.5mm2 50m
Wiring Specifications