Table of contents
Introduction……………………………………………….………………..………...5
Receiving and
inspection…………………………………………………..……………………...…..6
Equipment Damage or Loss
Return of Equipment
Preparing for
installation…………………………………………………….….…………..…….…..7
Safety Precautions
Installation &
Overview………………………………………………..……………….………….…..8
General Description, General Considerations, Securing the Block Up Converter
Installing the Block Up
Converter…………………………………………………………………………..….………………...…...9
Tools & Equipment, Site Considerations, Preparation
LED Indication…………………………………………………………………….……..………………...10
10 MHz Reference, Setting the L.O., Setting the TX and RX Frequencies
Recommended Test
Equipment………………….………………………………………….….….………..11
Connections and Mounting
Hardware………………………………………………………………….….……..…12
Functional
Overview………………………………………………………….……….…………..13
Operational
Procedure………………………………………………………….…………………..14
Maintenance……………………………………………………….…………………..15

ABE10KXHM User Manual
Page 3 of 32
Performance
Check……………………………………………….....…………….………………...16
Out-of Warranty Repair
Appendix 1 Specifications ……………..………………...….………….……………....17
Appendix 2 Mechanical
Drawing…………….………………………………….………………………………….18
Appendix 3 Spare Parts
Form………………..………………………………………………….…………………..19
Appendix 4 M&C Commands..…………….…….…………………………..………..………………….20
Appendix 5
M&C Connection Instructions………..………….…………………………..………..………………….25

ABE10KXHM User Manual
Page 4 of 32
Scope
This document covers the installation, operation, and maintenance of the ABE10KXHM BUC. It contains
information intended for engineers, technicians and operators working with the block up converter.
To make inquiries, or to report errors of fact or omission in this document, please contact Actox Corporation
at toll free 866-888-6087.

ABE10KXHM User Manual
Page 5 of 32
Introduction
The ABE10KXHM is a reliable, high quality, cost efficient stand-alone block up converter. The application for
this block up converter is Ku-Band VSAT communication in an outdoor environment. This line of superior
products, engineered using state of the art technology, is characterized by unparalleled durability and
dependability.
This is the smallest and lightest 10W L-To Ku-Band Block Up Converter and is designed to be mounted on the
feed horn. The unit is ideal for portable and mobile applications.
KEY FEATURES
RF frequency 13.75-14.50 GHz
IF frequency 950 to 1,700 MHz
Smallest package size and weight
Double L.O. (switchable 12.80 and 13.05 GHz)
Auto-ranging 15 - 60 VDC
Low power consumption (49W max)
Digital temperature compensation
L.O. lock and amplifier LED
Advanced M&C interface- combined RS-232/485,
Ethernet (HTTP and SNMP ver. 3) & FSK (optional)
Autosensing and Controllable Internal 10MHz
high stability reference (optional)
RoHS compliant

ABE10KXHM User Manual
Page 6 of 32
Receiving and Inspection
The block up converter is designed to function outdoors and will arrive in a standard shipping container.
Immediately upon receipt of the block up converter, check the packing slip against the actual equipment you
have received. Inspect the shipping containers exteriors for visible damage incurred during shipping.
CAUTION!
Handle the block up converter with extreme care. Excessive shock may damage block up converter’s
delicate internal components.
Using the supplied packing list, verify that all items have been received and undamaged during shipment.
Verify that all items are complete. If there are any omissions or evidence of improper packaging, please notify
Actox Corporation immediately.
Equipment Damage or Loss
Actox Corporation is not responsible for damage or loss of equipment during transit. For further information,
contact the responsible transport carrier.
When declaring equipment as damaged during transit, preserve the original shipping cartons to facilitate
inspection reporting.
Return of Equipment
When returning equipment to Actox Corporation for repair or replacement:
1. Identify, in writing, the condition of the equipment;
2. Refer to the Invoice, Purchase Order and the date the equipment was received.
Notify Actox Corporation RMA department of the equipment condition and obtain a Return Material
Authorization (RMA) number and shipping instructions.
NOTE
Do not return any equipment without an RMA number.
This is important for prompt, efficient handling of the
returned equipment and of the associated complaint.

ABE10KXHM User Manual
Page 7 of 32
Preparing for Installation
Before attempting to install or use the block up converter, we recommend that you first familiarize yourself
with the product by reading through this manual. Understanding the operation of the system will reduce the
possibility of incorrect installation, thereby causing damage or injury to yourself or others.
Safety Precautions
Carelessness or mishandling of the block up converter may damage the unit causing serious injury to yourself
or others. Please adhere to the following:
WARNING!!
If your unit is equipped with an AC power cord and plug, do not tamper with, or attempt to reconfigure, the
cord or plug supplied with the unit, as this can:
Result in personal injury;
Void the warranty;
Cause damage to the units or related equipment.

ABE10KXHM User Manual
Page 8 of 32
Installation and Overview
General Description
This section describes the installation and theory of operation of the block up converter.
ABE10KXHM is powered by +15~+60 VDC via IF connector.
It will amplify an input signal from an L-Band RF source up to a power level of 10 Watts (min) CW in Ku-
Band.
The block up converter can be used as a stand-alone unit or in a redundant configuration.
Specifications
Appendix 1. summarizes the technical specifications of the ABE10KXHM BUC. For mechanical
specifications, refer to the outline drawing, Appendix 2.
General Considerations
The block up converter shall meet all specifications over full bandwidth and under all environmental
conditions when terminated with a load of VSWR at 1.5:1 unless otherwise specified. All RF specifications
shall be met within five minutes after applying power, except gain flatness, which shall be met after a warm-up
period of ten minutes. During the warm-up period, the block up converter shall not exhibit any alarm or
require an RF mute input signal to reset any alarm/fault latches.
Securing the block up converter
Align the block up converter output waveguide flange with the mating flange of the antenna feeder waveguide.
Using the O-ring and hardware provided, connect the antenna feeder waveguide. Torque the flange screws to
16 inch-pounds (1.8 N-m). Attach the proper cables for waveguide for IF input, DC power and M&C if
equipped to the corresponding connectors of the block up converter.
The cylindrical connectors are labeled clearly and have different pin layouts. It is impossible to incorrectly
install the mating connectors.

ABE10KXHM User Manual
Page 9 of 32
Installing the Block-Up Converter
Tools and Test Equipment
Have on hand a standard electrician's tool kit and any tools listed in the antenna manufacturer's installation
instructions.
Site Considerations
The BUC is designed to mount on the antenna. Locate and install the antenna according to instructions
supplied by the antenna manufacturer. Choose an area that is free of extraneous interference from motors and
electrical equipment and has a clear line of sight from the antenna to the satellite. Lightning arrestors should be
used at the site to protect personnel and equipment.
Preparation
Mounting Considerations:
Optional Mounting Brackets are available that will facilitate mounting for most antennas.
The ODU must be mounted such that:
- Sufficient support is afforded to the BUC, the LNB and the Power supply to minimize the effects of antenna
sway in strong winds;
- Air movement across the heat fins is possible;
- The length of the Power supply cables is taken into consideration in determining the mounting location of the
power supply.
Throughout installation and during any polarization, azimuth or elevation adjustment, ensure that cables and
waveguide are not crimped or pinched.

ABE10KXHM User Manual
Page 10 of 32
10MHz Reference
The BUC must receive a stable external 10MHz reference provided by a stable signal source such as a signal
generator, satellite modem or injected externally with a Bias T (for example, ABT6ARN/ABT6ARF
manufactured by Actox Corporation) or a similar bias T type.
Please make sure to check the sticker on the BUC for the appropriate power source before any power
connections are performed:
Powered via MS or IF Universal 15-60VDC
A universal powered unit is powered through a 2-pin MS mating connector (which is included with the BUC)
or IF input by an external minimum 60W 24VDC or 48VDC power supply source.
Powered via only MS 15-60VDC (optional)
MS only powered unit uses a 2-pin MS mating connector (which is included with the BUC) with either a
24VDC or 48VDC external power source with at least 60W.
Setting the L.O.
Switchable L.O. can be switched mechanically by using the micro switch under the protective bolt (marked on
the connector side of the BUC), or electronically if the BUC is equipped with M&C interface.
To change the L.O. mechanically, the protective bolt needs to be removed, and the micro switch pressed in
with any small object such as toothpick. If the BUC is equipped with M&C interface, the L.O. can be switched
electronically with the appropriate M&C command or via GUI.
Setting the TX and RX Frequencies
All transmit and receive frequencies are set in the modem. For a direct connection to an L-band modem follow
the manufacturer’s instructions on setting the transmit and receive frequencies.
Ensure that it is safe to transmit prior to enabling the transmission.
LED Indication
SSPA LED Green All OK
SSPA LED Red Summary Alarm
L.O. LED Blinking Yellow L.O. is set to 12.80GHz
L.O. is set to 13.05GHz
NO POWER
External 10MHz Reference
10MHz is Absent
Internal 10MHz Reference
L.O. LED Yellow
NO LED indicators
10MHz LED Green
10MHz LED Red
10MHz LED Green Blinking
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Convertidor de medios de Actox

Actox
Actox ABCN50X Manual de usuario

Actox
Actox ABEN16KX Manual de usuario

Actox
Actox ABC25UKA Manual de usuario

Actox
Actox ABC40SKX Manual de usuario

Actox
Actox ABE10KFX Manual de usuario

Actox
Actox ABC40DC Manual de usuario

Actox
Actox ABE10UKA Manual de usuario

Actox
Actox ABEN25KX Manual de usuario

Actox
Actox ABE12KX Manual de usuario

Actox
Actox ABD100KX Manual de usuario