ACLAS EC320 Manual

E
C320 User settings manual
I
J-JY-EC320
The right product for your great idea!
EC320 User Settings Manual

E
C320 User settings manual
II
J-JY-EC320

E
C320 User settings manual
3
Setting code switch
By turning on the setting code function, the parameter setting of the reading module can be performed
by scanning the setting code.
*Open the setup code Close setup code
Output setup code content Output setup code content
Restore factory settings
By scanning the “Restore Factory Settings” barcode, all parameters of the reading module can be
restored to the factory configuration.
Restore Factory Settings
User default settings
In addition to the factory settings, the user can save the configuration that he often uses as the default
setting of the user. By scanning “Save current settings as user default settings”, the current
configuration information of the device can be saved as the default setting information of the user, if
the module is read. If there is already user default setting information, the new configuration
information will replace the original user default setting information after the operation.
By scanning "Restore User Defaults", you can switch the reading module to the user default
You can also modify the PC's access period to the HID device by scanning the following
setup code.settings.
Save current settings as user defaults Restore user default settings

E
C320 User settings manual
4
1 communication interface
The EC320 reading module provides a TTL-232 serial communication interface for communication with the host. Through
the communication interface, it is possible to receive reading data, control the reading module to issue commands, and change
the function parameters of the reading module.
1.1 serial communication interface
The serial communication interface is a common way to connect the reading module to the host device (such as PC, POS,
etc.). When the reading module is connected to the host using a serial cable, the system uses the serial communication mode
by default. When using the serial communication interface, the communication module and the host device must be completely
matched in the communication parameter configuration to ensure smooth communication and correct content.
Serial output
The serial communication interface of the reading module uses a TTL level signal (TTL-232), which adapts to most
system architectures. If the system needs to use an RS-232 form of architecture, it is necessary to add a conversion
circuit externally.The serial communication interface of the reading module uses a TTL level signal (TTL-232), which
adapts to most system architectures. If the system needs to use an RS-232 form of architecture, it is necessary to add a
conversion circuit externally.
The default serial communication parameters of the reading module are shown in Table 2 1. The baud rate of the
reading module can be modified by the serial port command, but the remaining parameters cannot be modified.
Table 2 1 Default serial communication parameters
Parameter
Default
Serial communication type
standard TTL-232
Baud rate
9600
check
no
Data bit
8
Stop bit
1
Hardware flow control
no
Baud rate setting

E
C320 User settings manual
5
1200bps 4800bps *9600bps
14400bps 19200bps

E
C320 User settings manual
6
38400bps 57600bps 115200bps
1.1.1 Serial Check Digit Configuration
Customers can modify the parity of the serial port by scanning the following configuration code.
*NONE ODD EVEN
1.1.1 Serial Port and Full Code Open Quick Configuration
In order to help customers quickly configure to serial port and full code open mode during the
secondary development process, you can scan the following configuration code to achieve quick
configuration.
Serial port & full code open
1.1 USB interface
When the reading module is connected to the host using a USB cable, the reading module can be
configured to the standard keyboard input mode by scanning the USB PC setting code.

E
C320 User settings manual
7
USB PC keyboard
*USB PC keyboard
You can also modify the PC's access period to the HID device by scanning the
following setup code.
*1ms 3ms
5ms 10ms
You can also modify the interval between valid messages and released messages by scanning the following
*0ms 1ms 5ms
10ms 15ms
You can also modify the interval between the release of the message and the next valid message by
scanning the following setup code.

E
C320 User settings manual
8
0ms *1ms 5ms
10ms 15ms

E
C320 User settings manual
9
You can also modify the state of CapsLock at the output by scanning the following
setup code.
*Off On
1.1USB virtual serial port
When the reading module is connected to the host using a USB cable, the reading module can be
configured as a virtual serial port output mode by scanning the USB virtual serial port setting code.
USB virtual serial port

E
C320 User settings manual
10
1 reading mode
1.1 manual mode
The manual reading mode is the default reading mode. In this mode, the reading module starts
reading after pressing the trigger button, and stops reading after the reading succeeds in outputting the
message or releasing the trigger button.
*manual mode
In this mode, after the reading module is idle for a certain period of time, it automatically enters the
deep sleep mode, which can be set by the following setting code.
Enable hibernation *Disable sleep function
After entering the sleep mode, you can wake up by pressing the button, and the device will restart
after exiting the sleep mode.
In addition, when Deep Sleep is not enabled, you can also set the idle time for a light
sleep by scanning the following setup code.
0ms *500ms
3000ms 5000ms
Tabla de contenidos