Thank you for purchasing Acekool Window Air Conditioner. Before operating this unit,
please read these instructions completely and keep the manual ready for further reference.
Window Air Conditioner CW2
USER MANUAL

01
03
05
06
13
18
20
CONTENTS
Important Safety Instructions
Electrical Requirements
Packing List
Installation & Assembly Instructions
Using Your Air Conditioner
Care and Cleaning
Troubleshooting
Your home in sync

Important Safety Instructions
Before installing and using your air conditioner, please read this owner's manual carefully.
Store thismanual in a safe place for future reference. Your safety and the safety of others
is very important to us. Please pay attention to all safety messages outlined in this user
manual.
To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow
the basic precautions below:
This is a safety alert symbol. This symbol alerts you to potential hazards that
can harm you or others or even cause death. All safety messages will directly
follow the safety alert symbol and/or the words "DANGER" or "WARNING".
Warning
Failure to immediately follow these instructions may cause serious injury or even death.
Danger
All Safety messages alert you of potential hazards, how to reduce the chance of injury,
and what can happen if instructions are not followed correctly.
The refrigerants used for air conditioners are environmentally friendly hydrocarbons R32.
This kind of erant is combustible and odorless. Moreover, it can burn and explode under
certain condition. However, there will be no risk of burning and explosion if you comply
with the following table to install your air conditioner in a room with an appropriate area
and use it correctly.
Compared with ordinary refrigerants, Refrigerant R32 is environmentally friendly and do
not destroy the ozone sphere and that its value of greenhouse effect is also very low.
Warning
Plug into a grounded 3 prong outlet.
Do not remove the ground prong.
Do not use a plug adapter.
Do not use an extension cord.
Unplug the air conditioner before servicing.
Use two or more people to move and install the air conditioner.
Introduction to Refrigerants R32
Your home in sync
01

Room area requests for air conditioner with Refrigerant R32
Refrigerant Capacity(Btu) Room Area
≤9K
≤12K
≤18K
≤24K
R32
Above 4m²
Above 4m²
Above 15m²
Above 25m²
Warning
Please read the manual before installation, using, maintenance.
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
Do not pierce or burn the appliance.
The appliance shall be stored in a room without continuously operating sources
(for example: open flames, an operating ignition gas appliance or an operating
electric heater.)
Please contact the nearest after-sale service center when maintenance is necessary.
At the time of maintenance, the maintenance personnel must strictly comply with
the Operation Manual provided by the corresponding manufacturer and any non-
professional is prohibited to maintain the air conditioner.
The handling, installation, storage, servicing and disposal must comply with the
provisions of gas-related national laws and regulations, and also national wiring
regulation.
It is necessary to clear away the refrigerant in the system when maintaining or
scrapping an air conditioner. Be aware that refrigerants may not contain an odour.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or supervision or instruction concerning use
of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Unit operation limits: Outdoor side 61~110, 80%RH, indoor side 61~90, 80%RH.
Your home in sync
02

Electrical Requirements
Electrical Shock
Recommended Ground Method
It is the customer's responsibility:
Hazard Plug into a grounded 3 prong outlet.
Do not remove the ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or
electrical shock.
To contact a qualified electrician.
To assure that the electrical installation is adequate and in conformance with the
National Electrical Code, ANSI/NFPA 70-latest edition, and all local codes and ordinances.
Warning
The electrical ratings for your air conditioner are listed on the model and serial number
label located on the front left side of the unit (when facing the front).
Specific electrical requirements are listed in the chart below. Follow the requirements
below for the type of plug on the power supply cord.
For your personal safety, this air conditioner must be grounded. This air conditioner is
equipped with a 3 prong power supply cord with a grounded plug. To minimize the poss-
ibility of electrical shock, the cord must be plugged into a 3 prong outlet and grounded
in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it
is the customer's responsibility to have a properly grounded 3 prong outlet installed by
a qualified electrician.
115 volt (103min.—127 max)
(6K-8K) 0-8 amps / (10K-12K) 0-12 amps
(6K-8K)10-amp time-delay fuse or circuit breaker
(10K-12K) 15-amp time-delay fuse or circuit breaker
Use on single outlet circuit only
Wiring Requirements Power Supply Cord
Your home in sync
03

LCDI Power Cord and Plug
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interrup-
tion) power cord that is requiredby UL. This power supply cord contains state-of-the-art
electronics that sense leakage current. If the cord is damaged and leakage occurs, power
will be disconnected from the unit.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning
properly.
To test the plug:
Plug power cord into a grounded 3 prong outlet
Press RESET (on some units a green light will turn on).
Press the TEST Button, the circuit should trip and cut all power to the air conditioner
(on some units a green light may turn off).
Press the RESET button for use. You will hear a click and the A/C is not ready for use.
The RESET button must be engaged for proper use.
The power supply cord must be replaced if it fails to trip when the TEST
button is pressed and the unit fails to rese.
Do not use the power supply cord as an ON/OFF switch. The power
supply cord is designed as a protection device.
A damaged power supply cord must be replaced with a new power
supply cord.
The power supply cord contains new user serviceable parts. Opening
the tamper-resistant case voids all warranty and performance claims.
TEST
RESET
NOTES:
NOTES: Your units power cord and plug may differ from the one shown.
Your home in sync
04

Packing List
Window Air Conditioner *1 Remote Control *1
AUTO
SPEED
AUTO
MODE
SMART
POWER
SLEEP FAN
SPEED
FAN
ONLY
AUTO
MODE
DISPLAY
TIMER ECO
COOL
Your home in sync
05
Top Rail (With sponge) *1
Sash Lock
(Two holes) *1
3/8"Screws *4 3/4"Screws *4 Remote Control
Battery*2
1/2"Screws *3
Window Sash Seal
(Sponge) *1
Foam Top Window
Gasket *1
Insulation strip
(Sponge) *2
Lock Frame *2 Filler Panels *2
(With "Left"&"Right"remark on the
front face)
(Thin sponge for back-up using) (Only for E-star model)

Installation & Assembly Instructions
Some assembly is required for your new air conditioner. Please read and follow these
instructions carefully.
This air conditioner is designed to be installed in a standard double-hung window with
a window width between 23" and 36" (584mm-914 mm).
The air conditioner can be installed without the accordion panels to fit in a narrow
window opening. See the window dimensions.
The Lower Sash (the lower part of the window that moves up and down) must allow
for 14.5" of vertical dearance when open. (See Fig.1).
All supporting parts must be secured to firm wood, masonry, or metal.
The electrical outlet must be within reach of the power cord.
14.5inch
368mm
23-36inch
584-914mm
Interior Wall
Stool
Sill Offset
Exterior
Wall
Fig.1
Save the product packaging and installation instructions for future reference.
Store the air conditioner in the product box when not in use for an extended period
of time.
NOTE:
Your home in sync
06
The air conditioner should be tilted about 3° for better drainage of condensate and
rainwater.

Fig.C
Fig.B
Fig.A
Top Rail
Bottom Box
Top Rail Assembly
Attaching the Top Rail to the Air Conditioner
The top rail must be assembled prior to installing the air conditioner in the window.
Tools Needed: Phillips Head Screw Driver
3/8"Screws *4
NOTE: For safety reasons, all 4 screws
must be used to attach the top rail.
Remove the air conditioner from the box and place on a hard and flat surface.
Remove top rail from the top of the packaging material as shown in Fig.A.
Align the hole in the top rail with those in the top of the unit as shown in Fig.B.
Secure the top rail to the unit with the 3/8" screws as shown in Fig.C.
Top Rail (With sponge) *1
When handling the unit, be careful to avoid cuts from the sharp metal edges and aluminum
fins on the front and rear coils.
Caution
Your home in sync
07

Fig.2 Fig.3
Fig.4
How to Install
NOTE: Top Rail and Sliding Panels at each side are offset to provide the proper pitch to
the rear of (5/16"). This is necessary for proper condensed water utilization and drainage.
If you are not using the Side Panels forany reason, this pitch to the rear must be maintained!
Place unit on floor, a bench or a table. There is a Left and Right Window Filler Panelbe
sure to use the proper panel for each side. When installed the flange for securing
the panel in place to the window sill will be facing into the room.
Hold the Accordion Panel in one hand and gently pull back the center to free the open
end. See Fig.2.
Slide the free end of the panel into the cabinet as shown in Fi.3. Slide the panel down.
Be sure to leave enough space to slip the top and bottom of the frame into the rails
on the cabinet.
Once the panel has been installed on the
side of the cabinet, make sure it sits secu-
rely inside the frame channel by making
slight adjustments. Slide the top and bot-
tom ends of the frame into the top and
bottom rails of the cabinet. See Fig.4.
Slide the panel all the way in and repeat
on the other side.
1
Your home in sync
08
Tabla de contenidos
Otros manuales de Acondicionador de aire de Acekool