acaia AO101 Manual de usuario

Acaia Orion
User Manual
AO101 / AO102
1.13.37

Introduction
Features
Interface Overview
Getting Started
Initial Setup
Getting Started
General Operation
Product Care Information
Battery Charge
Calibration
Care and Cleaning
Operations
Basic Operations
Set Preset Weight
Switch Mode
Empty Hopper
Mode Introduction
Mode 1 - Manual Dosing Mode
Mode 2 - Auto Dosing Mode
Mode 3 - Weighing Mode
Settings
Accessing the Orion’s Settings
Diagram of the Settings Menu
Appendix
Buttons
LED Indicators
Error Codes
Other
Specications
3
3
3
4
4
4
4
5
5
5
5
6
6
6
6
6
7
7
8
9
10
10
10
12
12
12
13
13
14
Contents
Modes
LED Indicator

Fast Weight-Based On-Demand Dosing
The Orion Bean Doser™ can dose 225 grams (1/2 lbs) in 12 seconds and 20 grams in 3 seconds
within the error margin of 2-3 beans.
Full Automatic Mode
Designed with a fully automatic mode for continuous dosing of multiple containers without pressing
any buttons.
Intuitive Dial Interface
A new dial interface with three preset modes for storing dierent target weights and allowing easy
access by rotating the dial for dierent functions.
Weighing Scale Mode
The Orion Bean Doser™ can function as a smart industrial weighing scale with a capacity of up to
3000 grams.
Statistic Tracking System
The Orion Bean Doser™ can track statistical information such as total number of doses or total
weight of the dosing session.
The Orion Bean Doser™ is designed for dosing green beans or roasted coee beans based
on weight.
Introduction
Features
3
Interface Overview
Presets
Power Button
Ounce Indicator
Connect Indicator
Charging Indicator
Rotate
Modes
LED Indicator
Dose Button

1. Prior to using your Orion for the rst time you should rinse and clean the bean hopper in warm
soapy water. Dry immediately after cleaning.
2. Attach the bean hopper on top.
3. Place a container on the weighing platform to avoid accidental dispensing.
4. Connect the power cord to the Orion.
5. Place coee beans into the hopper.
1. Make sure that the weighing platform is clean.
2. Turn on the Orion by pressing Power and place the container on the platform.
3. Set target weight by pressing Power. Adjust values with Dial then press Power to conrm.
4. Press Dose to start dosing. If the display shows [ CUP ] [ rESEt ], please place a container on
the platform.
5. When a dose is complete, press Power to return to dosing.
The Orion is designed for dosing portions of beans from 5 grams to a maximum of 3000 grams
per dose with an accuracy of +/- 2 beans (~0.5 g).
There are two dosing modes in the Orion — Manual mode and Auto mode. To choose between
modes, press and hold the Power button and the display will show the current mode of opera-
tion. Rotate the dial to switch modes.
Getting Started
Initial Setup
Getting Started
General Operation
4
To take full advantage of the Orion Mini’s many features, carefully read through the entire manual,
which contains step-by-step procedures, examples, and other information.
Warning: Incorrect handling of this product could result in personal injury or physical damage.

Product Care Information
Battery Charge
Calibration
Care and Cleaning
5
The Charging indicator will display when the battery is charging and will turn o when the
charger is removed. If the USB cable is not working, the indicator does not appear.
Please note that the Orion ONLY charges on the AC-DC adapter included in the package. It
does NOT charge with any other USB-C charger.
• Use a soft cloth with warm water only to clean the product.
• Do not use detergent or other chemicals for cleaning and soaking as it can damage the
anodized coating on the product.
Charging Indicator
Rotate
1. While the Orion is in Weighing Mode and the weighing unit is in grams, rapidly press the Dose
button multiple times until the LED display shows [ CAL ] and then [ 500 ].
2. Place a 500-gram calibration weight on the platform and wait for the Doser to execute the
calibration procedure.
3. The display shows [ -End- ] when the calibration procedure is completed.
* Note: Calibration weights of 100 g, 1000 g, 1500 g, 2000 g, and 3000 g can also be used. For
highest accuracy use Acaia calibration weights or F1 or F2 Class calibration weights. Inexpensive
lower-class calibration weights have a higher deviation from a true accurate weight.

Action Operation
Empty Hopper Press and hold Dose
Stop Emptying Press Dose
Back to Preset Press Power
Empty Hopper
To empty the bean hopper, you can press and hold the Dose button. The Orion will continuously
dispense the beans until you press the Dose button again to stop. Make sure you place a large
container on the platform for this operation.
There will be an ‘E’ indicator on the top left corner of the display when emptying the hopper.
In the main display menu, you may use the controls above to choose between presets, enter
dierent dosing modes, or start dosing with the current mode.
There are 3 presets in the Orion for storing desired weights. For example, you can set preset 1 at
18 g for dosing, preset 2 at 20 g, and preset 3 at 35 g. You may adjust the preset value with the
controls above.
There are 2 dierent modes in the Orion for operation — Manual dosing mode and Auto dosing
mode. You may set dierent modes using the controls above.
Operations
Basic Operations
Set Preset Weight
Switch Mode
6
Action Operation
Turn On Scale Press Power
Turn O Scale Double press Power
Toggle Presets Rotate Dial
Set Preset Weight Press Power, rotate Dial, then press Power / Dose
Switch Mode Press and hold Power, rotate Dial, then press Power / Dose
Start Dosing Press Dose
Reset Mode Press Power
Empty Hopper Press and hold Dose
Stop Emptying Hopper Press Dose
Action Operation
Enter Preset Weight
Setting Press Power
Change Value Rotate Dial
Save Preset Value Press Power / Dose
Action Operation
Enter Mode Setting Press and hold Power
Switch Mode Rotate Dial
Set Mode Press Power / Dose

This is the default mode for dosing.
Mode 1 - Manual Dosing Mode
7
Action Operation
Start Dosing Press Dose
Stop Dosing Press Dose
Pulse Beans Press Dose
Reset Mode Press Power
1. Select a preset by rotating the Dial. Adjust the preset value by pressing Power and rotating
the Dial. Press Power to conrm.
2. Press Dose, and the Orion will begin dosing until desired weight is reached within +/- 0.5 g
(solid green LED will display to indicate an accurate dose).
3. At the end of dosing, you may press Dose several times to ‘pulse’. Pulse will slowly add a few
more beans if needed.
4. Press Power to start a new dose.
• Manual dosing mode can dose on demand with a selected preset.
• A [ NOISE ] message will show when a container is removed from the Orion or when the plat-
form is touched during dosing. Please dose again.
Pulse in Manual dosing mode
The Orion has a pulse function that adds a few beans to the dose manually at the end of each
dose. To pulse (add) a few more beans at the end of each dose, simply press the Dose button
and the Orion will add a small amount of beans with each press. If one press doesn’t drop any
beans, you can press it multiple times until the desired weight is reached.
Mode Introduction

1. Switch into automatic dosing mode by pressing and holding Power and selecting the Auto mode
with the Dial. Press Power again to conrm the mode.
2. Select or adjust a preset weight.
3. Press Dose to start automatic dosing, the display will show [ rEADY ].
4. To start the rst dose, press Dose again and the automatic dosing will begin.
5. Remove the completed dose, and wait for the display to show [ rEADY ] again.
6. Place another container on top of the platform and dispensing will start again.
7. Press Power to set a dierent dose and leave the current auto dosing session.
• Auto dosing mode can dose automatically whenever a container is placed on the platform.
• There will be an ‘A’ indicator on the top left corner of the display when in Auto mode.
• A [ NOISE ] message will show when a container is removed from the Orion or the platform is
touched during dosing. Please dose again.
Pulse in Auto dosing mode
The pulse function also works in the auto dosing mode. To pulse (or add) a few more beans at the
end of each dose, simply press the Dose button and the Orion will add a small amount of beans with
each press. If one press does not dispense any beans, you can press it multiple times until the desired
weight is reached.
Auto dosing mode can dose automatically whenever a container is placed on the platform. There
will be an ‘A’ indicator on the top left corner of the display when in Auto mode.
At the end of auto dosing, you may press the Dose button to ‘pulse’ a few more coee beans if
required. A [ rEADY ] message will show on the display when auto dosing mode is in action.
To leave the [ rEADY ] display, press the Power button. You will be able to return to the preset
selection display.
Mode 2 - Auto Dosing Mode
8
Action Operation
Enter Ready State Press Dose
Start Dosing Press Dose
Stop Dosing Press Dose
Pulse Beans Press Dose
Reset Mode Press Power
Display Description
rEADY Place container on the platform; dosing will start when weight is
detected

The weighing mode is the Orion’s smart scale mode. It will function like an industrial weighing
scale with a 3000-gram capacity. To switch to weighing mode, rotate the Dial until a ‘W’ indicator
appears on the top left corner of the display.
• The weight of the object on the platform will be shown on the display.
• The Power and Dose buttons will function as ‘Zero’ and ‘Tare’.
Mode 3 - Weighing Mode
9
Action Operation
Reset Mode/Zero Press Power
Tare Press Dose

Action Operation
Enter Setting Mode Press and hold Power
Enter Setting Menu Press Dose
Setting Display Options Default
Speed SPEEd FASt, PrEC, grEEn PrEC
Zero Tracking trAcE 05, 1 d, 2 d, 3 d, 4 d, 5 d, O 1 d
Key Sound bEEP On, O On
Default Weighing Unit Unit g, oZ g
Cup Detection CUP.d On, O On
Calibration CAL (Start calibration) -
About About (Show the current Orion Firmware
version) -
1. With Orion powered on, press and hold Power to enter the Settings mode. The display will
show [ SEt ].
2. Press Dose to enter the Settings Menu. It will show the rst setting for [ SPEEd ].
Settings
Accessing the Orion’s Settings
Diagram of the Settings Menu
10
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Dispensador de acaia