ABLOY®DA460 SWING DOOR OPERATOR
Installation and commissioning manual

2
APPROVALS / STANDARDS
73/23/EEC (Low Voltage directive)
93/68/EEC (Low Voltage directive)
89/336/EEC (EMC directive)
Statement of fire doors by Technical Research Centre of Finland
------------------ THIS MANUAL CONTAINS IMPORTANT SAFETY INSTRUCTIONS ------------------
Warning - IT IS IMPORTANT FOR SAFETY OF PERSONS TO FOLLOW THESE INSTRUCTIONS.
------------------------------------ SAVETHESEINSTRUCTIONS -----------------------------------------
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
Do not allow children to play with fixed controls.
Frequently examine the installation for imbalance and sings of wear or damage to cables,
springs and mountings. Do not use if repair or adjustment is necessary.
Disconnect the supply when cleaning or other maintenance is being carried out.
Before installing the operator, check that the operator is in good mechanical condition and it
opens and closes properly.
Ensure that entrapment between door and the surroundings is avoided.
Ensure that the operator is suited for installation. Check temperature, humidity, door weights,
etc. restriction in line with specifications applicable in the manual or other Abloy® Oy material.
Note!
Instructions, design specifications and illustrations which are contained in this manual are not
binding. Abloy Oy reserves the right as part of ongoing product development to make changes
without previous notice.

3
CONTENTS
Approvals ............................................................................................................................2
Revision .............................................................................................................................. 4
Content of delivery ............................................................................................................. 5
General information ............................................................................................................ 6
Operation ........................................................................................................................... 7
Main switch and mode switch ..............................................................................................7
Door weight ....................................................................................................................... 8
Installation ......................................................................................................................... 9
Internal connections ......................................................................................................... 14
Commissioning ................................................................................................................. 15
A safe door ....................................................................................................................... 18
External connections ........................................................................................................ 19
Connection examples ....................................................................................................... 21
Self diagnostic ................................................................................................................. 27
Maintenance ..................................................................................................................... 28
Spare parts ....................................................................................................................... 29

4
REVISION
Following pages have been revised:
Page Revision
14 Safetysensor-unit added into connections.
15-16 Settings updated.
18 Added a note about safety sensors.
19-26 All connections drawings updated.
28 Safety sensor diagnistics added.
29 Safetysensor-unit info added.
As at 22.05.2015.

5
CONTENT OF DELIVERY
DA460 Swing door operator
- screws 4 pcs M8x22
DA103 Mounting plate
- screws 6 pcs 5,5x32
DA147 Standard arm
- screws 2 pcs 5,5x32 and
1 pcs M8x30
DA148 Extended arm
- screws 2 pcs 5,5x32 and
1 pcs M8x30
DA149 Sliding arm
- screws 2 pcs 5,5x50 and
1 pcs M8x30
DA150 Extension piece
- 10 mm + M8x35
- 20 mm + M8x35 + M8x45
- 60 mm + M8x90

6
GENERAL INFORMATION
Technical data
Measures
• 595 (L) x 85 (H) x 107 (W) mm
• Weight 6,5 kg
• Supply voltage 90-264 VAC, 47-63 Hz
• Rated output 70 W
• Enclosure class IP20
Temperature range
• Storage -30...+85°C (in dry premises)
• Operation: -15...+50°C (in dry premises)
• The automatic swing door operator must not be installed in applications where it is
subjected to water or snow.
Interfaces
• Voltage output 24 VDC, stabilized, output current 500 mA
• Voltage output 12 VDC, stabilized, output current 1,0 A
• The total load must not exceed 12W
• Potential free relay output, preset to operate 2 seconds
2 A @ 30 VDC resistive load
Features
• Usage for heavy density of pedestrian traffic
• Push&Go as a standard feature
• Normal and delayed impulse
• Adjustable hold open time 0...60 s or sequential use
• Fire detector connection
• Free Swing operation
• Door hold force
• Prepull before opening
• Secondary DC inlet for power back up (24 VDC (•±15 %), 3A)
• Maximum opening angles:
With standard arm 100 degrees
With sliding arm on the opening side 100 degrees
With sliding arm on the closing side 90 degrees

7
OPERATION
ABLOY®DA460 is an electromechanical swing door operator for heavy use. The door operator includes new
free swing function: when using the door manually it operates lightly without motor’s resistance and the door
can be left in open position when required. It can be used on both single and double, internal and external, fire
and emergency exit doors.
Safety features
Opening cycle: If the door is obstructed in opening cycle. The door is set free and hold open time is started.
After 1 second, new trial is done to open the door. Maximum amount for trials is 4. If this is exceeded or hold
open time is end, the door is closed.
Closing cycle: If the door is obstructed in closing cycle. The door is set free and 4 new trials are done to close
the door. If the closing is still obstructed, the operator tries to close the door at one minute intervals.
MAIN SWITCH AND MODE SWITCH
Main switch Mode switch
When the power is switched on, the mains switch lights up.
1= on 0= off
Functions of mode switch
AUTO:
The operator opens the door for the duration of the hold open time.
MAN:
Manual use.
OPEN:
The door is held permanetly open.
NOTE! There is 3 seconds constant delay when mode switch is changed from
position OPEN to AUTO or MAN.

8
DOOR WEIGHT
50
60
70
80
90
100
110
120
130
140
150
160
170
180
60 70 80 90 100 110 120 130 140 150
50
60
70
80
90
100
110
120
130
140
150
160
170
180
60 70 80 90 100 110 120 130 140 150
Standard arm
Sliding arm
Door weight [kg]
Door width [cm]
Door weight [kg]
Door width [cm]

9
INSTALLATION
Tools required
Drill
Set of ball ended allen wrenches
# 2 Phillips head screwdriver
Flat blade screwdrivers, 2 pcs
Steps of installation
- Preparing installation
- Installing the mounting plate
- Mounting the operator and the arm
- Connecting the operator to mains
- Commissioning
- Testing
- Connecting impulse devices
Preparing installation
- Check the proper function of the door
- hinges
- door clearance
- Check the proper function of the lock
- lock case
- striker plate
Removal of housing
Note! Remove the protective earth wire from cover and connect it back after installation.
Keep the mains disconnected when removing or mounting cover.

10
Installing the mounting plate
Operator is to be installed on the transom, with the main switch located towards the hinge.
Use the mounting plate DA103 with the door operator ensuring the installation base is level and securely fixed
to a flat surface. Minimum requirement for wall profile is 5 mm (steel).
Installation measurements for the standard arms DA147, DA148 and sliding arm DA149 to closing side.
Hinge line
63 296,5 530 593
28,5
28,5 13
41,5
70
83
39,5
10
Ø 10
Ø 10 Ø 10
Mounting plate DA103
Ø 30
Otros manuales para DA460
2
Tabla de contenidos
Otros manuales de Abridor de puerta de garaje de Abloy
Manuales populares de Abridor de puerta de garaje de otras marcas

Craftsman
Craftsman 139.53924 Manual de usuario

Chamberlain
Chamberlain MyQ 940ESTD Manual de usuario

Automatic Technology
Automatic Technology GDO-9V1 SecuraLift Manual de usuario

Westfalia
Westfalia 19 36 07 Manual de usuario

Chamberlain
Chamberlain HD520EVP Manual de usuario

Cardin
Cardin BL Series Manual de usuario