1.0 General ............................................................................................................................................ 3
2.0 Cabinet Overall Description......................................................................................................... 3
3.0 Cabinet Conversion Kits................................................................................................................5
4.0 Accessories and Spare Parts.........................................................................................................5
5.0 3M™Cross-Connect Cabinet Installation ...................................................................................5
6.0 Sealing Cable Entrance Points......................................................................................................7
7.0 Shield Bonding.................................................................................................................................7
8.0 Installing Frames .............................................................................................................................7
9.0 Splicing Frame Block Tails to Field Cable .................................................................................. 8
10.0Identicationofthe3M™Blocks using Number Labels........................................................... 8
11.0 Jumper Wire Management .......................................................................................................... 8

1.0 General
1.1 Theseinstructionsprovidetheinformation
necessaryfortheinstallationofthe3M™Cross-
Connect Cabinets 4220VB and 4220VC Series.
The 4220VB and 4220VC series cabinets
are multiuse in that they can be ordered, or
convertedinthefield,asapadmount,stake
mount, pole mount or wall mount. They are less
than45"inheighttomeettheneedsofright-of-
wayandhouseframesthataccommodate3M™
Quick Connect System (QCS) 2810 Blocks. The
cabinetsareavailableempty,withfullyloaded
framesorpartiallyloadedframes.Cabinet
mounting, cable preparation, splicing, jumper
installationandaccessoriesofthecabinetare
covered in these instructions.
1.2 3M QCS Frames can be ordered loaded with
blocks, partially loaded with blocks or empty.
The block tails can be terminated with 3M™MS2™
Splicing Modules or 3M™710 Splice Connectors.
1.3 To make these instructions easier to read,
abbreviated cabinet product numbers will be
used throughout the steps. Use the Naming
Guide to determine the proper cabinet product
numbersneededforyourapplication.
4220VB-QCSHC-300-300/T-A
4220V Cabinet series
B 300 pair
QCS 3M™Quick Connect System (9QCS) 2810 Blocks
HC High Cat, high twist block tails
300 Maximumnumbersofpairsinthecabinet
300 Numberofpairsinstalledfromthefactory
T Block tails e/w 3M™710 Modules
A Almond
1.4 Toolsareneededforthecabinetinstallation:
• 3/8" and 1/2" socket wrench sets
• Module/connector splicing tools
• Standard hand tools
Additionalmaterialsneededforcabinetinstallation:
• Port sealing materials
• Splicing connectors
• 3M™Scotchlok™Shield Bond Connectors and bond
per approved company practice
•Identication/locationlabels
2.0 3M™Cabinet Overall Description
Cabinet
Product
Max Pair
Count
QCS 2810
Max # of
Frames
QCS 2810
Frame
Number
Dimensions
H/W/D
(in)
Single
Sided
Low
Prole
4220VB 300 1 QCS3
44 7/8 x
12 3/8 x
10 1/8
X X
4220VC 600 1 QCS6 44 7/8 x
18 × 10 1/8 X X
2.1 ClearanceRequirementsofCabinets
Door Swing A B
4220VB 25 1/2" 22 7/8"
4220VC 36 1/2" 28 1/2"
A
B
378-0013-7947-4-A September 2015

2.2 3M™Cross-Connect Cabinets 4220VB Series
with 3M™Quick Connect System (QCS) 2810
Blocks
2.3 3M™Cross-Connect Cabinets 4220VC Series
with 3M™Quick Connect System (QCS) 2810
Blocks
478-0013-7947-4-ASeptember 2015

3.0 3M™Cabinet Conversion Kits
3.1 Pole/wall mount conversion kits
a. Top entry cap
b. Bottom entry plate
c. Cabinet hanger brackets ( 2 top, 1 bottom)
d. Pole attachment hanger bracket (1)
e. Splitportcap(fortoporbottom)
f. Portcoverplate(fortoporbottom)
3.2 Pad mount conversion kit
a. (includes 3M 4220 SVB/VB-PMK-Grade
Pedcab BTM Entry Grade/Pole MT)
3.3 Stake mount conversion kit
a. 3M™Stake Mount Kit 4056-SVS-A
4.0 3M™Accessories and Spare Parts
4.1 3M™Quick System (QCS) 2810 blocks
4.2 Capsfor3M™Quick Connect System (QCS)
2810 blocks
4.3 PriorityCapsfor3M™Quick Connect System
(QCS) 2810 blocks
4.4 3M™Single Pair Test Probe 2827 and Dish
4.5 3M Single Pair Test Probe 2827
4.6 3M™Flex Port Kit 4297-4220SVB/VB-BP Kit
PanI.D.4"x9"(for4220VB300pair)
4.7 3M™Flex Port Kit 4297-4220SVC/VC-BP Kit
Bread Pan I.D. 4" x 11" Wide Flange
(for4220VC600pair)
4.8 3M™Jumper Wire Spools
a. 4068 – 800' 24 AWG orange/white
jumper wire
b. 4069 – 250' 24 AWG orange/white
jumper wire
c. 4368 – 800' 22 AWG red/white
jumper wire
d. 4369 – 250' 22 AWG red/white
jumper wire
5.0 3M™Cross-Connect Cabinet
4220VB/4220VC Installation
Note: Install feeder and distribution cables allowing
10.5' above the pad.
5.1 Pad mount application
1. Position cabinet on pad
a. Removeframe
b. Removebottomfrontentryplateoncabinet
(ifrequired)
c. Installbackhalfof3M™Flex Port Kit 4297
(ifinstalling)
2. Ensure cabinet to pad alignment is square
3.Ensurecablestevenlyinsidecable
entrance chamber
4.Re-installbottomfrontentryplateon
cabinet(ifremoved)
5.Installfrontplateof3M™Flex Port Kit 4297
(ifinstalling)
6. Secure the cabinet to the pad
a.Reinstallthefourmountinglugsthat
secured the cabinet to the shipping pallet
b.Markthepadinthecenterofthe
mounting lug hole
c. Remove mounting lugs
d. Drill holes in pad per your company
directive
e. Install appropriate anchors per your
company directive
f.Reinstallmountinglugs
g. Shim cabinet as required to set level on
the pad
h. Bolt cabinet to pad per your company
directive
578-0013-7947-4-A September 2015

5.2 Stake mount application
a. Carefullyremoveearthfromaroundcables
to establish their location
b. Open doors on cabinet assembly
c. Removeblockframe
d. Removebottomfrontaccesspanel
e. Removebottomframesupport
f. Fill excavation with washed gravel to within
4"oftopofbottombracket
g. Place cabinet over cables in a vertical
position with cabinet centered over cables
h. Place anchor stakes on each side
i. Placeawoodenblockontopofstake
j. Using a sledge hammer, drive stake until
both bolt holes line up
k. Secureanchorstakestothesidesofthe
cabinet with bolts provided
l. Fill cabinet base with washed gravel to
within4"oftopofskirt
5.3 Pole mount application
1. Follow your company practice on attaching
‘pole mount hardware’
2. Attach the pole bracket at 60" above the
ground line
3. Attach the top and bottom mounting
bracketsonthebackofthecabinet
a. Make sure both brackets are aligned and
plumb with the cabinet
4. Hang the cabinet on the bracket
attached to pole
a. The top cabinet brackets support the
cabinet’s weight
5. Secure bottom cabinet bracket to the
pole with a lag bolt
3M™Top Pole Mount Bracket 4295 B,C,D
3M™Pole-mount Hanger Brackets installed on the back
of a 3M™Cross-Connect Cabinet 4220VB or 4220VC
678-0013-7947-4-ASeptember 2015

6.0 Sealing Cable Entrance Point
6.1 3M™Plastic Split Gland Kit 4097-F
1. Cleanandscuffcableinlocationofsplit
gland placement
2. Wrap sealing tape around the cable to a
diameter ¼" larger than cable port
3. Installbackhalfofsplitglandintocabinet
plate
4. Installfronthalfofsplitglandaroundcable
and bolt to cabinet plate
5. Bolttwohalvesofsplitglandtogether
Sealing cable with 3M™Split Gland Kit 4097-F & BE
6.2 Flexible Top Port Entry
1. Removethefrontplatefromtheflexport
body entry kit
2. Install the port body onto the threaded
studs
3. Reinstallthefrontplatetotheportbody
4. Sealaroundcablesbelowtopofflexport
5. Sealaroundcablesintheflexportwith
expandingfoam
7.0 Shield Bonding
1. Install 3M™Shield Bond Connector 4460 or
4462 per your company practice
2. Attach a bond strap between the shield
bond connector and the cabinet bond plate
8.0 Installing the 3M™Quick Connect
System (QCS) 2810 frames
1. Resttheframeonthebottomframesupport
bracket
2. Aligntheframepivottabswiththeslots
inthebottomframesupportbracketand
drop in
3. Attachthesafetycabletotheeyeletonthe
topofthebacksideoftheframe
4. Pivotframeuptotopframesupportbracket
778-0013-7947-4-A September 2015

5. Secureframetotopframesupportbracket
with 216C tool
9.0 Splice Frame Block Tails to Field
Cable
1. Dressfieldcabletocompleteanupand
downloopofconductors
2. Allowsufficientlengthtosplicetomodules
storedinbackofframe
3. Secure conductor loops to cable tie rack in
backofcabinet
4. Splicethefieldcabletotheblocktailsper
your company practice
5. Use 3M™Cable Ties to store the completed
bindersofsplicemodulesinthebackofthe
frame
NOTE: Allow adequate loop length to allow the frames
to pivot down
10.0 Identification of 3M™Quick
Connect System (QCS) 2810
Blocks Using Number Labels
10.1 Removeprotectortapefromidentificationpads
on the blocks in the cabinet.
10.2 Selectlabels:bluefordistributionorgreenfor
feeder.Detachastripof20labelswithyour
countfromsheet.Carefullyremoveprotective
backingfromstrip.
10.3 Align the proper number, such as 1-11-21, etc.,
withtheblockpadsonleftandpressintoplace.
Align numbers, such as 10-20-30, etc. with right
side block pads and press into place. Remove
thetoplinerofthenumbers.
10.4 Fill in binding post log on the cabinet door with
thecablepaircountinformation.
11.0 Jumper Wire Installation and
Routing of the 3M™Quick
Connect System (QCS) 2810
Blocks
11.1 Openfeederpairjumpercapbypushingupon
latch and rotating up. Insert jumper wire ends A
(tip)leftandB(ring)rightintowireopeningsin
cap, making sure they are inserted all the way to
thebackofthecap.
878-0013-7947-4-ASeptember 2015

11.2 While holding the jumper wires in place, close
thecapandpresstosnapthelatchfirmlyinto
place.
11.3 Route the jumper wires to distribution pair
through wire loops on block ends and through
vertical and horizontal wireways. Cut jumper
wires to appropriate length, leaving at least 5 cm
(2in.)ofslack.
11.4 Terminate the jumper wires to the distribution pair
by repeating the procedure described in steps 15.1
and 15.2.
11.5 Terminate additional jumper wires by repeating
the above procedure.
11.6 To remove jumper wires, open the cap and pull
wiresstraightoutfromblock.
978-0013-7947-4-A September 2015

Communication Markets Division
6801 River Place Blvd.
Austin, TX 78726-9000
Phone 1-800-426-8688
Web www.3M.com/Telecom
Please recycle. Printed in USA © 3M 2015.
All rights reserved. 78-0013-7947-4-A
3M, Scotchlok and MS2are trademarks of 3M Company.
All other trademarks are the property of their respective owners.
Important Notice
All statements, technical information, and recommendations related to 3M’s products are based on information believed to be reliable, but the
accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended
application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M’s current
publications, or any contrary statements contained on your purchase order shall have no force or eect unless expressly agreed upon, in writing, by an
authorized ocer of 3M.
Warranty; Limited Remedy; Limited Liability.
This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER
WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M’s option, to replace or repair the
3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any direct, indirect, special,
incidental or consequential loss or damage arising from this 3M product, regardless of the legal theoryasserted.
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Electricidad industrial de 3M
Manuales populares de Electricidad industrial de otras marcas

S&C
S&C Vista SD Manual de usuario

Murata
Murata GRM0335C2A7R3CA01 Series Manual de usuario

Siemens
Siemens 3VA9988-0BM10 Manual de usuario

Siemens
Siemens SITRANS LVS100 Manual de usuario

Murata
Murata GRM32ER60G227ME05 Series Manual de usuario

Siemens
Siemens SENTRON SUPERSWITCH 3KL82 Series Manual de usuario